Page 131

LS 6000 Series Product Reference Guide

Baud Rate (Cont’d)

BAUD RATE 9600

BAUD RATE 19,200

5-98

Page 132

Programming the LS 6000

Parity A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.

Odd If you select ODD parity, the parity bit has a value 0 or 1, based on data, to ensure than an odd number of 1 bits are contained in the coded character.

ODD

5-99

Page 133

LS 6000 Series Product Reference Guide

Parity (Cont’d) Even If you select EVEN parity, the parity bit has a value 0 or 1, based on data, to ensure than an even number of 1 bits are contained in the coded character.

EVEN

Mark Select MARK parity and the parity bit is always 1.

MARK

5-100

Page 134

Programming the LS 6000

Parity (Cont’d) Space Select SPACE parity and the parity bit is always 0.

SPACE

None Select None if no parity is desired.

NONE

5-101

Page 135

LS 6000 Series Product Reference Guide

Check Receive Errors Select whether or not the parity, framing, and overrun of received characters are checked. The type of parity used is selectable through the PARITY parameter.

CHECK FOR RECEIVED ERRORS

DO NOT CHECK FOR RECEIVED ERRORS

5-102

Page 136

Programming the LS 6000

Hardware Handshaking The data interface consists of an RS-232C port. The port has been designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). If Standard RTS/CTS handshaking is selected, scan data is transmitted according to the following sequence: !

The controller reads the CTS line for activity. If CTS is asserted, the controller waits up to 2 seconds for the host to negate the CTS line. If, after 2 seconds (default), the CTS line is still asserted, the scanner sounds a transmit error and any scanned data is lost. When the CTS line is negated, the controller asserts the ! RTS line and waits up to 2 seconds for the host to assert CTS. When the host asserts CTS, data is transmitted. If, after 2 seconds (default), the CTS line is not asserted, the scanner sounds a transmit error and discards the data. When data transmission is complete, the controller ! negates RTS 10 msec after sending the last character. The host should respond by negating CTS. The ! controller checks for a negated CTS upon the next transmission of data. During the transmission of data, the CTS line should be asserted. If CTS is deasserted for more than 50 ms between characters, the transmission is aborted, the scanner sounds a transmission error, and the data is discarded. If the above communications sequence fails, the scanner issues an error indication. In this case, the data is lost and must be rescanned.

5-103

Page 137

LS 6000 Series Product Reference Guide

Hardware Handshaking (Cont’d) If Hardware Handshaking and Software Handshaking are both enabled, Hardware Handshaking takes precedence. Note: The DTR signal is jumpered active. Scan one of the following bar codes to select an option below.

No Hardware Handshaking

NONE

Standard RTS/CTS Hardware Handshaking

STANDARD RTS/CTS

5-104

Page 138

Programming the LS 6000

Hardware Handshaking (Cont’d) RTS/CTS Option 1 When RTS/CTS Option 1 is selected, the scanner asserts RTS before transmitting and ignores the state of CTS. The scanner deasserts RTS when the transmission is complete.

RTS/CTS OPTION 1

RTS/CTS Option 2 When Option 2 is selected, RTS is always high or low (userprogrammed logic level). However, the scanner waits for CTS to be asserted before transmitting data. If CTS is not asserted within 2 seconds (default), the scanner issues an error indication and discards the data.

RTS/CTS OPTION 2

5-105

Page 139

LS 6000 Series Product Reference Guide

Hardware Handshaking (Cont’d) RTS/CTS Option 3 When Option 3 is selected, the scanner asserts RTS prior to any data transmission, regardless of the state of CTS. The scanner waits up to 2 seconds (default) for CTS to be asserted. If CTS is not asserted during this time, the scanner issues an error indication and discards the data. The scanner deasserts RTS when transmission is complete.

RTS/CTS OPTION 3

5-106

Page 140

Programming the LS 6000

Software Handshaking This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. There are five options. If Software Handshaking and Hardware Handshaking are both enabled, Hardware Handshaking takes precedence. Scan the appropriate bar code to select one of the following options.

None When this option is selected, data is transmitted immediately.

NONE

5-107