For the Symbol LS-6005 and Symbol LS-6004
Page 52
Programming
Host Type If you’re using a Synapse cable, your host is autodetected, so no host bar codes need to be scanned. If not, select an IBM 46XX, RS-232 or USB host from the following bar code menus.
IBM 46XX Host Types (LS 6005i) To select one of the following as a POS Interface, scan the appropriate bar code below. Note: To properly communicate with 468X/9X terminals, the driver corresponding to the port being used must be loaded and enabled when you are configuring your terminal system. See your terminal’s operating manual for details.
Port 5B
5-11
Page 53
LS 6000i Series Product Reference Guide
Host Type (Cont’d)
Port 9B
Port 17/9E
5-12
Page 54
Programming
Host Type (Cont’d) RS-232C Host Types (LS 6004i) Three RS-232C hosts are set up with their own parameter default settings (Table 5-2). Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal sets the defaults listed below. These defaults take precedence over standard defaults. So if you select Fujitsu RS232C, then select the standard defaults, the Fujitsu defaults still take precedence. Table 5-2. Terminal Specific RS-232C
Parameter
Standard
ICL
Fujitsu
Nixdorf Mode A/ Mode B
Transmit Code ID
No
Yes
Yes
Yes
Data Transmission Format
Data as is
Data/ Suffix
Data/ Suffix
Data/ Suffix
Suffix
CR/LF (7013)
CR (1013)
CR (1013)
CR (1013)
Baud Rate
9600
9600
9600
9600
Parity
Even
Even
None
Odd
5-13
Page 55
LS 6000i Series Product Reference Guide
Table 5-2. Terminal Specific RS-232C (Continued) Nixdorf Mode A/ Mode B
Parameter
Standard
ICL
Fujitsu
Hardware Handshaking
None
RTS/ CTS Option 3
None
RTS/CTS Option 3
Software Handshaking
None
None
None
None
Serial Response Time-out
2 Sec.
9.9 Sec.
2 Sec.
9.9 Sec.
Stop Bit Select
One
One
One
One
ASCII Format
8-Bit
8-Bit
8-Bit
8-Bit
Beep On <BEL> Disabled Disabled Disabled
Disabled
RTS Line State
*Low = No data to send
Low
High
Low
*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.
5-14
Page 56
Programming
RS-232C Host Types (Cont’d) Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal enables the transmission of Code ID Characters as listed in Table 5-3, below. These Code ID Characters are not programmable and are separate from the Transmit Code ID feature. The Transmit Code ID feature should not be enabled for these terminals.
Table 5-3. Terminal Specific Code ID Characters ICL
FUJITSU NIXDORF
UPC-A
“A”
“A”
“A”
UPC-E
“E”
“E”
“C0”
EAN-8
“FF”
“FF”
“B”
EAN-13
“F”
“F”
“A”
Code 39
“C” <len>
None
“M”
Codabar
“N” <len>
None
“N”
Code 128
“L” <len>
None
“K”
I 2 of 5
“I” <len>
None
“I”
UCC/EAN 128
“L” <len>
None
“P”
Bookland EAN
“F”
“F”
“A”
5-15
Page 57
LS 6000i Series Product Reference Guide
RS-232C Host Types (Cont’d) To select an RS-232C Host Interface, scan one of the following bar codes.
STANDARD RS-232C
ICL RS-232C
5-16
Page 58
Programming
RS-232C Host Types (Cont’d)
NIXDORF RS-232C Mode A
NIXDORF RS-232C Mode B
5-17
Page 59
LS 6000i Series Product Reference Guide
RS-232C Host Types (Cont’d)
FUJITSU RS-232C
5-18
Page 60
Programming
Baud Rate Baud rate is the number of bits of data transmitted per second. The scanner's baud rate setting should match the data rate setting of the host device. If not, data may not reach the host device or may reach it in distorted form.
BAUD RATE 300
5-19
Page 61
LS 6000i Series Product Reference Guide
Baud Rate (Cont’d)
BAUD RATE 600
BAUD RATE 1200
5-20