Page 186

Appendix A Programming Reference UCC/EAN-128 UCC/EAN-128 is a convention for printing data fields with standard Code 128 bar code symbols. UCC/EAN128 symbols are distinguished by a leading FNC 1 character as the first or second character in the symbol. Other FNC 1 characters are used to delineate fields. When EAN-128 symbols are read, they are transmitted after special formatting strips off the leading FNC 1 character and replaces other FNC 1 characters with the ASCII 29 GS control character. When AIM symbology identifiers are transmitted, the modifier character indicates the position of the leading FNC 1 character according to AIM guidelines. For example, ]c1 indicates a UCC/EAN-128 symbol with a leading FNC1 character. A-1

Page 187

LS 6000i Series Product Reference Guide

Standard Code 128 bar codes which do not have a leading FNC 1 may still be used but are not encoded according to the EAN-128 convention. Standard Code 128 and UCC/EAN-128 may be mixed in an application. The LS 6000i autodiscriminates between these symbols, and can enable or disable one or both code types via bar code menus. Table A-1 indicates the behavior of the LS 6000i in each of the four possible parameter settings. Table A-1. Reading Standard Code128 & UCC/EAN 128 Standard Code 128

UCC/ EAN128

Effect and Example

Disable

Disable

No Code 128 symbols can be read.

Disable

Enable

Read only symbols with leading FNC 1. Examples: FNC1ABCDFNC1E are read as ABCD29E AFNC1BCDFNC1E are read as ABCD29E FNC1FNC1ABCDFNC1E are read as ABCD29E ABCDFNC1E cannot be read ABCDE cannot be read

A-2

Page 188

Programming Reference

Table A-1. Reading Standard Code128 & UCC/EAN 128 (Continued) Standard Code 128

UCC/ EAN128

Effect and Example

Enable

Disable

Read only symbols without leading FNC 1. Examples: FNC1ABCDFNC1E cannot be read AFNC1BCDFNC1E cannot be read FNC1FNC1ABCDFNC1E cannot be read ABCDFNC1E is read as ABCD29E ABCDE is read as ABCDE

Enable

Enable

Read both types of symbols. Examples: FNC1ABCDFNC1E are read as ABCD29E AFNC1BCDFNC1E are read as ABCD29E FNC1FNC1ABCDFNC1E are read as ABCD29E ABCDFNC1E is read as ABCD29E ABCDE is read as ABCDE

A-3

Page 189

LS 6000i Series Product Reference Guide

AIM Code Identifiers Each AIM Code Identifier contains the three-character string ]cm where: ] c m

= = =

Flag Character (ASCII 93) Code Character (see Table A-2) Modifier Character (see Table A-3)

Table A-2. AIM Code Identifiers Code Character

A-4

Code Type

A

Code 39

C

Code 128, ISBT 128, EAN128

E

UPC/EAN e

RSS Family, EAN/UCC Composites (RSS & UCC/EAN-128 only)

F

Codabar

G

Code 93

I

Interleaved 2 of 5

L

PDF417, MicroPDF417

M

MSI Plessey

S

D 2 of 5, IATA 2 of 5

X

Code 39 Trioptic, Bookland EAN

Page 190

Programming Reference

Modifier Characters The modifier character is the sum of the applicable option values based on Table A-3. Table A-3. Modifier Characters Code Type Code 39

Option Value

Option

0

No check character or Full ASCII processing.

1

Reader has checked one check character.

3

Reader has checked and stripped check character.

4

Reader has performed Full ASCII character conversion.

5

Reader has performed Full ASCII character conversion and checked one check character.

7

Reader has performed Full ASCII character conversion and checked and stripped check character.

Example:A Full ASCII bar code with check character W, A+I+MI+DW, is transmitted as ]A7AimId where 7 = (3+4).

A-5

Page 191

LS 6000i Series Product Reference Guide

Table A-3. Modifier Characters (Continued) Code Type Code 128

Option Value

Option

0

Standard data packet, no Function code 1 in first symbol position.

1

Function code 1 in first symbol character position.

2

Function code 1 in second symbol character position.

Example:A Code (EAN) 128 bar code with Function 1 character in the first position, FNC1 Aim Id is transmitted as ]C1AimId I 2 of 5

0

No check digit processing.

1

Reader has validated check digit.

3

Reader has validated and stripped check digit.

Example:An I 2 of 5 bar code without check digit, 4123, is transmitted as ]I04123 Codabar

0

No check digit processing.

1

Reader has checked check digit.

3

Reader has stripped check digit before transmission.

Example:A Codabar bar code without check digit, 4123, is transmitted as ]F04123

A-6

Page 192

Programming Reference

Table A-3. Modifier Characters (Continued) Code Type

Option Value

UPC/EAN

Option

0

Standard packet in full EAN country code format, which is 13 digits for UPC-A and UPC-E (not including supplemental data).

1

Two-digit supplement data only.

2

Five-digit supplement data only.

4

EAN-8 data packet.

Example:A UPC-A bar code 012345678905 is transmitted as ]E00012345678905 Bookland EAN

0

No options specified at this time. Always transmit 0.

Example:A Bookland EAN bar code 123456789X is transmitted as ]X0123456789X RSS Family Note: In UCC/EAN128 emulation mode, RSS is transmitted using Code 128 rules (i.e., ]C1).

0

No option specified at this time. Always transmit 0. RSS-14 and RSSLimited transmit with an Application Identifier “01”.

Example: An RSS-14 bar code 100123456788902 is transmitted as ]e001100123456788902.

A-7

Page 193

LS 6000i Series Product Reference Guide

According to AIM standards, a UPC with supplemental bar code is transmitted in the following format: ]E0 (UPC chars) (terminator) ]E2 (supplemental) (terminator) In the LS 6000i, however, the format is changed to: ]E0 (UPC chars) ]E2 (supplemental) Therefore, a UPC with two supplemental characters, 01234567890510, is transmitted to the host as a 21character string, ]E00012345678905]E110.

A-8

Page 194

Programming Reference

ASCII Character Set Refer to the table below for ASCII values. Table A-4. ASCII Character Set ASCII Value

Full ASCII Code 39 Encode Char

1000 1001

Full ASCII Code 39 Encode Char Keystroke

Keystroke

ASCII Value

%U

CTRL 2

1024

$X

CTRL X

$A

CTRL A

1025

$Y

CTRL Y

1002

$B

CTRL B

1026

$Z

CTRL Z

1003

$C

CTRL C

1027

%A

CTRL [

1004

$D

CTRL D

1028

%B

CTRL \

1005

$E

CTRL E

1029

%C

CTRL ]

1006

$F

CTRL F

1030

%D

CTRL 6

1007

$G

CTRL G

1031

%E

CTRL -

1008

$H

CTRL H

1032

Space

Space

1009

$I

CTRL I

1033

/A

!

1010

$J

CTRL J

1034

/B

‘

1011

$K

CTRL K

1035

/C

#

1012

$L

CTRL L

1036

/D

$

1013

$M

CTRL M

1037

/E

% &

1014

$N

CTRL N

1038

/F

1015

$O

CTRL O

1039

/G

‘

1016

$P

CTRL P

1040

/H

(

1017

$Q

CTRL Q

1041

/I

)

1018

$R

CTRL R

1042

/J

*

1019

$S

CTRL S

1043

/K

+

1020

$T

CTRL T

1044

/L

,

1021

$U

CTRL U

1045

-

-

1022

$V

CTRL V

1046

.

.

1023

$W

CTRL W

1047

/

/

A-9

Page 195

LS 6000i Series Product Reference Guide

Table A-4. ASCII Character Set (Continued) ASCII Value

Full ASCII Code 39 Encode Char

Full ASCII Code 39 Encode Char Keystroke

Keystroke

ASCII Value

1048

0

0

1073

I

I

1049

1

1

1074

J

J

1050

2

2

1075

K

K

1051

3

3

1076

L

L

1052

4

4

1077

M

M

1053

5

5

1078

N

N

1054

6

6

1079

O

O

1055

7

7

1080

P

P

1056

8

8

1081

Q

Q

1057

9

9

1082

R

R

1058

/Z

:

1083

S

S

1059

%F

;

1084

T

T

1060

%G

<

1085

U

U

1061

%H

=

1086

V

V

1062

%I

>

1087

W

W

1063

%J

?

1088

X

X

1064

%V

@

1089

Y

Y

1065

A

A

1090

Z

Z

1066

B

B

1091

%K

[

1067

C

C

1092

%L

\

1068

D

D

1093

%M

]

1069

E

E

1094

%N

^ _

1070

F

F

1095

%O

1071

G

G

1096

%W

‘

1072

H

H

1097

+A a

A-10

Page 196

Programming Reference

Table A-4. ASCII Character Set (Continued) Full ASCII Code 39 Encode Char

Keystroke

ASCII Value

1098

+B b

1113

+Q

1099

+C c

1114

+R r

1100

+D d

1115

+S s

1101

+E e

1116

+T t

1102

+F f

1117

+U u

1103

+G g

1118

+V v

1104

+H h

1119

+W w

ASCII Value

Full ASCII Code 39 Encode Char Keystroke q

1105

+I i

1120

+X x

1106

+J j

1121

+Y y

1107

+K k

1122

+Z z

1108

+L l

1123

%P

{

1109

+M m

1124

%Q

|

1110

+N n

1125

%R

}

1111

+O o

1126

%S

1112

+P p

1127

~ Undefined

A-11

Page 197

LS 6000i Series Product Reference Guide

Table A-4. ASCII Character Set (Continued) ALT Keys

Keystroke

ALT Keys

Keystroke

ALT Keys

2064

ALT 2

2075

ALT K

2086

Keystroke ALT V

2065

ALT A

2076

ALT L

2087

ALT W

2066

ALT B

2077

ALT M

2088

ALT X

2067

ALT C

2078

ALT N

2089

ALT Y

2068

ALT D

2079

ALT O

2090

ALT Z

2069

ALT E

2080

ALT P

2091

ALT [

2070

ALT F

2081

ALT Q

2092

ALT \

2071

ALT G

2082

ALT R

2093

ALT ]

2072

ALT H

2083

ALT S

2094

ALT 6

2095

ALT -

2073

ALT I

2084

ALT T

2074

ALT J

2085

ALT U

Misc. Key

Keystroke

Misc. Key

Keystroke

3001

PA 1

3009

CMD 7

3017

°

3002

PA 2

3010

CMD 8

3018

1/2

3003

CMD 1

3011

CMD 9

3019

3004

CMD 2

3012

CMD 10

3020

§

3005

CMD 3

3013

¥

3021

|

3006

CMD 4

3014

£

3022

0/00

3007

CMD 5

3015

¤

3008

CMD 6

3016

¬

A-12

Misc. Key Keystroke

Page 198

Programming Reference

Table A-4. ASCII Character Set (Continued) PF Keys

Keystroke

PF Keys

Keystroke

PF Keys

Keystroke

4001

PF 1

4009

PF 9

4017

PF 17

4002

PF 2

4010

PF 10

4018

PF 18

4003

PF 3

4011

PF 11

4019

PF 19

4004

PF 4

4012

PF 12

4020

PF 20

4005

PF 5

4013

PF 13

4021

PF 21

4006

PF 6

4014

PF 14

4022

PF 22

4007

PF 7

4015

PF 15

4023

PF 23

4008

PF 8

4016

PF 16

4024

PF 24

F Keys

Keystroke

F Keys

Keystroke

F Keys

Keystroke

5001

F1

5014

F 14

5027

F 27

5002

F2

5015

F 15

5028

F 28

5003

F3

5016

F 16

5029

F 29

5004

F4

5017

F 17

5030

F 30

5005

F5

5018

F 18

5031

F 31

5006

F6

5019

F 19

5032

F 32

5007

F7

5020

F 20

5033

F 33

5008

F8

5021

F 21

5034

F 34

5009

F9

5022

F 22

5035

F 35

5010

F 10

5023

F 23

5036

F 36

5011

F 11

5024

F 24

5037

F 37

5012

F 12

5025

F 25

5038

F 38

5013

F 13

5026

F 26

5039

F 39

A-13

Page 199

LS 6000i Series Product Reference Guide

Table A-4. ASCII Character Set (Continued) Numeric Keypad

Keystroke

Numeric Keypad

Keystroke

Numeric Keypad

Keystroke

6042

*

6049

1

6056

8

6043

+

6050

2

6057

9

6044

Undefined

6051

3

6058

Enter

6045

-

6062

4

6059

Num Lock

6046

.

6063

5

6060

00

6047

/

6064

6

6048

0

6065

7

Extended Keypad

Keystroke

Extended Keypad

Keystroke

Extended Keypad Keystroke

7001

Break

7008

Backspace

7015

7002

Delete

7009

Tab

7016

Dn Arrow

7003

Pg Up

7010

Print Screen

7017

Left Arrow

7004

End

7011

Insert

7018

Right Arrow

7019

Back Tab

7005

Pg Dn

7012

Home

7006

Pause

7013

Enter

7007

Scroll Lock

7014

Escape

A-14

Up Arrow