Page 122
Programming
Random Weight Check Digit A 4-digit or 5-digit random weight check digit may be embedded in a UPC-A or EAN-13 bar code for additional price verification. To enable either of these options, or disable the option completely, scan the appropriate bar code below.
DISABLE RANDOM WEIGHT CHECK DIGIT
ENABLE 4-DIGIT RANDOM WEIGHT CHECK DIGIT
ENABLE 5-DIGIT RANDOM WEIGHT CHECK DIGIT
5-81
Page 123
LS 6000i Series Product Reference Guide
UPC-A Preamble Three options are given for lead-in characters for UPCA symbols transmitted to the host device: transmit system character only, transmit system character and country code (“0” for USA), and no preamble transmitted. The lead-in characters are considered part of the symbol.
NO PREAMBLE (<DATA>)
5-82
Page 124
Programming
UPC-A Preamble (Cont’d)
SYSTEM CHARACTER (<SYSTEM CHARACTER> <DATA>)
SYSTEM CHARACTER & COUNTRY CODE (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)
5-83
Page 125
LS 6000i Series Product Reference Guide
UPC-E Preamble Three options are given for lead-in characters for UPCE symbols transmitted to the host device: transmit system character only, transmit system character and country code (“0” for USA), and no preamble transmitted. The lead-in characters are considered part of the symbol.
NO PREAMBLE (<DATA>)
5-84
Page 126
Programming
UPC-E Preamble (Cont’d)
SYSTEM CHARACTER (<SYSTEM CHARACTER> <DATA>)
SYSTEM CHARACTER & COUNTRY CODE (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)
5-85
Page 127
LS 6000i Series Product Reference Guide
Convert UPC-E to UPC-A This parameter converts UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and be affected by UPC-A programming selections (e.g., Preamble, Check Digit). Scanning DO NOT CONVERT UPC-E TO UPC-A allows you to transmit UPC-E (zero suppressed) decoded data.
CONVERT UPC-E TO UPC-A (ENABLE)
DO NOT CONVERT UPC-E TO UPC-A (DISABLE)
5-86
Page 128
Programming
EAN Zero Extend If this parameter is enabled, five leading zeros are added to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols. Disabling this parameter returns EAN-8 symbols to their normal format.
ENABLE EAN ZERO EXTEND
DISABLE EAN ZERO EXTEND
5-87
Page 129
LS 6000i Series Product Reference Guide
UPC/EAN Predecode Block UPC/EAN bar codes are made up of two blocks representing “left” and “right” halves. For example, bar code 1234567890 is divided into left block “12345”, and right block “67890”. To maximize its aggressiveness, the LS 6000i can decode a UPC/EAN symbol by “splicing” together a left block read by one scan line, and a right block read by another.
Reject Predecode Block This option provides additional protection (beyond the embedded check digit) against mis-splicing a UPC/EAN block from a symbol that has just been decoded (but has not completely exited the scanner’s field of view), with a block from a new symbol that has just been presented to the scanner. This option requires the scanner to compare the new symbol against the symbol just decoded to see if there are common blocks. If either the left or right blocks match between symbols, the scanner rejects the common block for the programmed Decode Time-Off interval.
REJECT PREDECODE BLOCK
5-88
Page 130
Programming
Accept Predecode Block This option allows immediate decode of a new UPC/ EAN bar code regardless of the previously decoded UPC/EAN bar code’s block content.
ACCEPT PREDECODE BLOCK
5-89
Page 131
LS 6000i Series Product Reference Guide
UPC/EAN Security Level The LS 6000i offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are provided for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so be sure to choose only that level of security necessary for any given application.
UPC/EAN Security Level 0 This is the default setting which allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
UPC/EAN SECURITY LEVEL 0
UPC/EAN Security Level 1 As bar code quality levels diminish, certain characters become prone to misdecodes before others (i.e., 1, 2, 7, 8). If you are experiencing mis-decodes of poorly printed
5-90