Page 72

Programming

Software Handshaking This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. There are five options. If Software Handshaking and Hardware Handshaking are both enabled, Hardware Handshaking takes precedence. Scan the appropriate bar code to select one of the following options.

None When this option is selected, data is transmitted immediately.

NONE

5-31

Page 73

LS 6000i Series Product Reference Guide

Software Handshaking (Cont’d) ACK/NAK When this option is selected, after transmitting data, the scanner expects either an ACK or NAK response from the host. Whenever a NAK is received, the scanner transmits the same data again and waits for either an ACK or NAK. After three unsuccessful attempts to send data when NAKs are received, the scanner issues an error indication and discards the data. The scanner waits up to the programmable Host Serial Response Time-out to receive an ACK or NAK. If the scanner does not get a response in this time, it issues an error indication and discards the data. There are no retries when a time-out occurs.

ACK/NAK

5-32

Page 74

Programming

Software Handshaking (Cont’d) ENQ When this option is selected, the scanner waits for an ENQ character from the host before transmitting data. If an ENQ is not received within 2 seconds, the scanner issues an error indication and discards the data. The host must transmit an ENQ character at least every 2 seconds to prevent transmission errors.

ENQ

ACK/NAK with ENQ This combines the two previous options.

ACK/NAK with ENQ

5-33

Page 75

LS 6000i Series Product Reference Guide

Software Handshaking (Cont’d) XON/XOFF An XOFF character turns the scanner transmission off until the scanner receives an XON character. There are two situations for XON/XOFF: •

XOFF is received before the scanner has data to send. When the scanner has data to send, it then waits for an XON character before transmission. The scanner waits up to 2 seconds to receive the XON. If the XON is not received within this time, the scanner issues an error indication and discards the data.

•

XOFF is received during a transmission. Data transmission then stops after sending the current byte. When the scanner receives an XON character, it sends the rest of the data message. The scanner waits indefinitely for the XON.

XON/XOFF

5-34

Page 76

Programming

Host Serial Response Timeout This parameter specifies how long the scanner waits for an ACK, NAK, or CTS before determining that a transmission error has occurred. This only applies when in one of the ACK/NAK Software Handshaking modes, or RTS/CTS Hardware Handshaking option. The delay period can range from 0.0 to 9.9 seconds in 0.1-second increments. After scanning the bar code below, scan two numeric bar codes beginning on page 5-138. If you make an error or wish to change your selection, scan CANCEL bar code on page 5-143.

HOST SERIAL RESPONSE TIME-OUT

5-35

Page 77

LS 6000i Series Product Reference Guide

RTS Line State This parameter is used to set the idle state of the Serial Host RTS line. Scan a bar code below to select LOW RTS line state or HIGH RTS line state.

HOST: LOW RTS

HOST: HIGH RTS

5-36

Page 78

Programming

Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.

1 STOP BIT

2 STOP BITS

5-37

Page 79

LS 6000i Series Product Reference Guide

ASCII Format This parameter allows the scanner to interface with devices requiring a 7-bit or 8-bit ASCII protocol.

7-BIT

8-BIT

5-38

Page 80

Programming

Beep on <BEL> When this parameter is enabled, the scanner issues a beep when a <BEL> character is detected on the RS232C serial line. <BEL> is issued to gain a user's attention to indicate an illegal entry or other important event.

BEEP ON <BEL> CHARACTER (ENABLE)

DO NOT BEEP ON <BEL> CHARACTER (DISABLE)

5-39

Page 81

LS 6000i Series Product Reference Guide

Intercharacter Delay Select the intercharacter delay option matching host requirements. The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. The delay period can range from no delay to 99 msec in 1-msec increments. After scanning the bar code below, scan two bar codes beginning on page 5-138 to set the desired time-out. If you make an error or wish to change your selection, scan CANCEL bar code on page 5-143.

INTERCHARACTER DELAY