Page 23

Chapter 1 The LS 5700/5800 Scanner Scanning Made Easy The LS 5700 and LS 5800 are compact, high performance, omni-directional scanners that bring easy, hands-free scanning to your point-of-sale system. • The LS 5700 mounts on the counter and lets you scan side-to-side, or perpendicular to the face of the scanner.

• The LS 5800 is designed for in-counter mounting. It allows slide-through scanning of items, thereby enhancing productivity and throughput. The LS 5700 and LS 5800 scanners (Figure 1-1) are identical electrically, and provide the same reliable scanning capabilities. In instances where no distinction is drawn between the LS 5700 and LS 5800, they will be collectively referred to as the “scanner.”

LS 5700

LS 5800

Figure 1-1. LS 5700/LS 5800 Scanners

1-1

Page 24

LS 5700/LS 5800 Product Reference Guide Pass an item’s bar code symbol past the scanner window and the item number is quickly sent to your host system. The scanner is compact, easy to install, and fits most check stand designs. The scanner decodes UPC/EAN, UPC/EAN Supplementals, Code 39, Code 39 Full ASCII, I 2 of 5, Code 128, and Codabar. Additionally, UPC/EAN Random Weight Goods Check Digit, UCC 128 Coupon Code, Bookland EAN-13, and ITF-14 are supported. In most instances, changing host systems is as easy as scanning the appropriate bar code and changing the cable. The scanner provides connection for an optional Synapse™ compatible hand-held scanner such as an LS 4004. The hand-held scanner allows you to scan heavy items without lifting them. Some scanner models have an integrated radio frequencybased electronic article surveillance (EAS) system for deactivating tags. An optional external kit is available for models that do not contain an integrated antenna.

1-2

Page 25

Chapter 2 Set Up

Unpacking Remove the scanner from its packing and inspect it for damage. Figure 2-1 shows the items which should be included with the shipment: • Scanner

• Power supply or power cable (if applicable) • RS-232C Host interface cable, or Synapse Adapter cable and Synapse cable

• Quick Reference Guide

LS 5700 / LS 5800 Quick Reference Guide

Cables • Synapse • Synapse Adapter • Power Supply • Synapse Power Adapter • RS-232

Power Supply

Figure 2-1. Items Contained in a Typical Scanner Package

2-1

Page 26

LS 5700/LS 5800 Product Reference Guide Some host terminals (e.g., IBM 46xx Series) can supply power to the scanner. In those cases, an external power supply is not required. See your Symbol representative for more information. If the scanner or any other content is missing, or was damaged in transit, call the Symbol Support Center at the telephone number listed on page xi. KEEP THE PACKING. It is the approved shipping container and should be used if you ever need to return your equipment for servicing.

Input/Output Ports The scanner contains the ports as shown in Figure 2-2.

Figure 2-2. Input/Output Ports

Power In Port. When external power is required, the input to this port is 5 V @ 550 mA nominal. Current draw on this port should not exceed 1.2 A.

2-2

Page 27

Set Up Host Port. A 6-pin modular connector. Plug the Synapse Adapter cable, or Synapse Power Regulator cable into this port.

Hand-Held Laser Scanner Port. A 6-pin modular connector. Plug a Symbol Synapse-compatible scanner such as the LS 4004, LS 3603MX, or LS 3203ER into this port. This scanner can be used to program the LS 5700/LS 5800, and adapts itself to the LS 5700/ LS 5800 decode parameters (i.e., code types, lengths and check digits). A separate AC adapter may be necessary when using a handheld scanner. Current draw on this port should not exceed 200 mA.

RS-232C Port. A 10-pin modular connector. This input/output port is used to connect the scanner to an RS-232C host. It is also used as an auxiliary port to connect serial devices such as a scale, magstripe reader, etc. Current draw on this port should not exceed 200 mA.

2-3

Page 28

LS 5700/LS 5800 Product Reference Guide

Connecting Your Scanner To an IBM 468x/469x Terminal, Port 9E or Port 17 Attach the Synapse Power Regulator Y-cable as shown in Figure 2-3. One connector goes to the Host port and the other to the Power port. Attach a Synapse cable between the Power Regulator cable and the IBM terminal. No additional power supply is needed, as the IBM terminal supplies power to the scanner. If additional scanning versatility is desired, plug a Synapse-compatible scanner into the Hand-Held Laser Scanner port.

IBM 468x/469x Port 9E, 17

LS 5700/ LS 5800 Synapse Cable Synapse Cable Regulatory Y-Cable p/n 25-17086-01

Figure 2-3. Connecting to an IBM Terminal, Port 9E or Port 17

In this configuration, the scanner draws power from the host.

2-4

Page 29

Set Up

To an IBM 468x/469x Terminal, Port 5B RS-232C or Synapse Host Attach the Synapse Adapter cable to the Host port on the scanner. Attach the appropriate Synapse cable to the Adapter cable and to the host terminal. Attach the power supply to the Power port. If additional scanning versatility is desired, plug a Synapse-compatible scanner into the Hand-Held Laser Scanner port (Figure 2-4).

Synapse Adapter Cable p/n 25-17072-01 LS 5700/ LS 5800

Host Terminal

Synapse Cable

Power

Figure 2-4. Connecting to an IBM Terminal Port 5B RS-232C

In this configuration, an external power supply is required.

2-5

Page 30

LS 5700/LS 5800 Product Reference Guide

To an RS-232C Host Using the RS-232C Port Connect one end of the RS-232C cable to the RS-232C port, and the other to the host. Attach the power supply to the Power port. If additional scanning versatility is desired, plug a Synapse-compatible scanner into the Hand-Held Laser Scanner port (Figure 2-5).

RS-232 Host

LS 5700/ LS 5800

Power

Figure 2-5. Connecting to an RS-232C Host

In this configuration, an external power supply is required.

2-6