The text of a manual · part 22 of 36
LS 5700/LS 5800 Product Reference Guide: Chapter 5 Parameter Menus, pages 205 to 214
Pages 205 to 214 of 352, from LS 5700/LS 5800 Product Reference Guide
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-5700 and Symbol LS-5800
Page 205
Parameter Menus
Code Types & Options CLSI Editing If enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Note that symbol length does not include start and stop characters.
ENABLE CLSI EDITING
5-141
Page 206
LS 5700/LS 5800 Product Reference Guide
Code Types & Options Disable CLSI Editing
DISABLE CLSI EDITING
5-142
Page 207
Parameter Menus
Code Types & Options NOTIS Editing If enabled, this parameter strips the start and stop characters from decoded Codabar symbol.
ENABLE NOTIS EDITING
5-143
Page 208
LS 5700/LS 5800 Product Reference Guide
Code Types & Options Disable NOTIS Editing
DISABLE NOTIS EDITING
5-144
Page 209
Parameter Menus
Custom Tailoring Scanning Range Select the decode range that best suits your scanning needs. FULL RANGE covers the maximum scanning range, and is recommended for in-counter applications and installations where there is no opportunity for inadvertent reads. Decode range data is shown in Table 4-2 on page 4-5.
FULL RANGE
5-145
Page 210
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring Scanning Range MEDIUM RANGE is recommended for on-counter applications and installations where full range may allow inadvertent reads. Decode range data is shown in Table 4-2 on page 4-5 .
MEDIUM RANGE
5-146
Page 211
Parameter Menus
Custom Tailoring Scanning Range SHORT RANGE is recommended for on-counter applications where counter space is at a minimum. Decode range data is shown in Table 4-2 on page 4-5 .
SHORT RANGE
5-147
Page 212
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring Internal Beeper This parameter connects the beeper signal to the internal beeper.
ENABLE INTERNAL BEEPER
5-148
Page 213
Parameter Menus
Custom Tailoring Disable Internal Beeper This parameter disconnects the beeper signal to the internal beeper.
DISABLE INTERNAL BEEPER
5-149
Page 214
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring RS-232C Port External Beeper This parameter connects the beeper signal to the RS-232C Port.
ENABLE RS-232C PORT EXTERNAL BEEPER
5-150