Page 135

Parameter Menus

RS-232C Port Auxiliary Options Do Not Check Parity

DO NOT CHECK PARITY

5-71

Page 136

LS 5700/LS 5800 Product Reference Guide

RS-232C Port Auxiliary Options Hardware Handshaking The data interface consists of an RS-232C port. The port has been designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). If Standard RTS/CTS handshaking is selected, scan data is transmitted according to the following sequence:

• The controller reads the CTS line for activity. If CTS is asserted, the controller waits up to 2 seconds for the host to negate the CTS line. If, after 2 seconds the CTS line is still asserted, the scanner sounds a transmit error and any scanned data is lost.

• When the CTS line is negated, the controller asserts the RTS line and waits up to 2 seconds for the host to assert CTS. When the host asserts CTS, data is transmitted. If, after 2 seconds, the CTS line is not asserted, the scanner sounds a transmit error and discards the data.

• When data transmission is complete, the controller negates RTS 10 msec after sending the last character.

• The host should respond by negating CTS. The controller checks for a negated CTS upon the next transmission of data.

5-72

Page 137

Parameter Menus

RS-232C Port Auxiliary Options Hardware Handshaking During the transmission of data, the CTS line should be asserted. If CTS is de-asserted for more than 50 msec between characters, the transmission is aborted, the scanner sounds a transmission error, and the data is discarded. If the above communications sequence fails, the scanner issues an error indication. In this case, the data is lost and must be rescanned. Note:

The DTR signal is jumpered active.

5-73

Page 138

LS 5700/LS 5800 Product Reference Guide

RS-232C Port Auxiliary Options Hardware Handshaking None Scan the bar code below if no Hardware Handshaking is desired.

NONE

5-74

Page 139

Parameter Menus

RS-232C Port Auxiliary Options Hardware Handshaking Standard RTC/CTS Scan the bar code below to select Standard RTS/CTS Hardware Handshaking.

STANDARD RTS/CTS

5-75

Page 140

LS 5700/LS 5800 Product Reference Guide

RS-232C Port Auxiliary Options Software Handshaking This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. NONE When this option is selected, data is transmitted immediately.

NONE

5-76

Page 141

Parameter Menus

RS-232C Port Auxiliary Options Software Handshaking ON/XOFF An XOFF character turns the scanner transmission off until the scanner receives an XON character. There are two situations for XON/XOFF:

• XOFF is received before the scanner has data to send. When the scanner has data to send, it then waits for an XON character before transmission. The scanner waits up to 2 seconds to receive the XON. If the XON is not received within this time, the scanner issues an error indication and discards the data.

• XOFF is received during a transmission. Data transmission then stops after sending the current byte. When the scanner receives an XON character, it sends the rest of the data message. The scanner waits indefinitely for the XON.

XON/XOFF

5-77

Page 142

LS 5700/LS 5800 Product Reference Guide

RS-232C Port Auxiliary Options Serial Response Time-out This parameter determines the maximum period allowed to elapse before the scanner assumes end of transmission. The delay period can range from 0.0 to 9.9 seconds in .1 second increments. After scanning the bar code below, scan two bar codes on pages 5-246 to 5-255 to set the desired time-out.

SERIAL RESPONSE TIME-OUT

5-78

Page 143

Parameter Menus

RS-232C Port Auxiliary Options Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits (one or two) selected depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match those device requirements.

1 STOP BIT

5-79

Page 144

LS 5700/LS 5800 Product Reference Guide

RS-232C Port Auxiliary Options Stop Bit Select

2 STOP BITS

5-80