The text of a manual · part 23 of 24
LS 4800/4900 Product Reference Guide: Glossary, pages 220 to 229
Pages 220 to 229 of 239, from LS 4800/4900 Product Reference Guide
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-4804 and Symbol LS-4904
Page 220
Glossary
APERTURE
The opening in an optical system defined by a lens or baffle that establishes the field of view.
ASCII
American Standard Code for Information Interchange. A 7 bit-plus-parity code representing 128 letters, numerals, punctuation marks, and control characters. It is a standard data transmission code in the U.S.
ASYMMETRIC WIDTH GROWTH
Non-uniform growth of elements in a printed symbol.
AUTODISCRIMINATION
The ability of an interface controller to determine the code type of a scanned bar code. After this determination is made, the information content can be decoded.
AVERAGE BAR WIDTH GROWTH
Average deviation of bars from nominal widths over the entire symbol.
BAD CHECK DIGIT
Error message resulting from failure of the check digit to calculate properly.
BAD DATA CHARACTER
Error message caused by failure of one or more data characters to decode properly.
BAD PRINT CONTRAST
Error message due to lack of contrast between the background and the bars of the symbol.
BAR
The dark element in a printed bar code symbol.
Glossary-1
Page 221
LS 4800/4900 Product Reference Guide
BAR CODE DENSITY
The number of characters represented per unit of measurement (e.g., characters per inch in one-dimensional symbologies, characters per square inch in PDF417).
BAR HEIGHT
The dimension of a bar measured perpendicular to the bar width.
BAR WIDTH
Thickness of a bar measured from the edge closest to the symbol start character to the trailing edge of the same bar.
BAR WIDTH DEVIATION
Increase or decrease in bar width as compared with nominal bar width.
BAUD RATE
A measure of the data flow or number of signaling events occurring per second. When one bit is the standard "event," this is a measure of bits per second (bps). For example, a baud rate of 50 means transmission of 50 bits of data per second.
BIDIRECTIONAL READING CAPABILITY
The ability to decode a symbol successfully by reading in complementary (opposite) directions across bars and spaces.
BIT
Binary digit. One bit is the basic unit of binary information. Generally, eight consecutive bits compose one byte of data. The pattern of 0 and 1 values within the byte determines its "meaning."
BUFFER
An area of memory allocated for data storage. In this context, a buffer's data storage capacity is needed when data can flow into the device more quickly than the device can process that data. Buffering the data preserves it until it can be processed.
BYTE
On an addressable boundary, eight adjacent binary digits (0 and 1) combined in a pattern to represent a specific character or numeric value. Bits are numbered from the right, 0 through 7, with bit 0 the low-order bit. One byte in memory can be used to store one ASCII character.
CHARACTER
A pattern of bars and spaces which either directly represents data or indicates a control function, such as a number, letter, punctuation mark, or communications control contained in a message.
Glossary-2
Page 222
Glossary
CHARACTER SET
Those characters available for encodation in a particular bar code symbology.
CHECK DIGIT
A digit used to verify a correct symbol decode. The scanner inserts the decoded data into an arithmetic formula and checks that the resulting number matches the encoded check digit. Check digits are required for UPC and Code 128 but are optional for other symbologies. Using check digits decreases the chance of substitution errors when a symbol is decoded.
CLUSTER
One of three subsets of mututally exclusive codeword definitions within PDF417.
CODABAR
A discrete self-checking code with a character set consisting of start/stop characters (A B C D or * T N E), digits 0 to 9, and these additional characters: ( - $ : / , +).
CODE
Set of unambiguous rules specifying the way in which data may be represented.
CODEWORD
In PDF417, a single group of bars and spaces (4 bars and 4 spaces, for a total of 17 module widths) which represents one or more numbers, letters, or other symbols.
CODEWORD PD (CODEWORD PERCENT DECODE)
Within a PDF417 symbol, the percentage of codewords which decoded successfully; the number of good codewords divided by the total number of codewords (data codewords plus error correction codewords).
CODE LENGTH
Number of data characters in a bar code between the start and stop characters, not including those characters.
CODE 128
A high density symbology which allows the interface controller to encode all 128 ASCII characters without adding extra symbol elements.
CODE 3 OF 9 (CODE 39)
A versatile and widely used alphanumeric bar code symbology with a set of 43 character types, including all uppercase letters, numerals from 0 to 9, and 7 special characters (- . / + % $ and space). The code name is derived from the fact that 3 of 9 elements representing a character are wide, while the remaining 6 are narrow.
Glossary-3
Page 223
LS 4800/4900 Product Reference Guide
CONTINUOUS CODE
A bar code or symbol in which all spaces within the symbol are parts of characters. There are no intercharacter gaps in a continuous code. The absence of gaps allows for greater information density.
COUNTRY FLAG
In EAN-8 and EAN-13 codes, two or three digits which appear immediately following the left guard bar pattern.
DEAD ZONE
An area within a scanner's field of view, in which specular reflection may prevent a successful decode.
DECODE
To recognize a bar code symbology (e.g., UPC/EAN) and then analyze the content of the specific bar code scanned. To translate the bar/space pattern into defined characters within a defined symbology.
DECODE ALGORITHM
A decoding scheme that converts pulse widths into data representation of the letters or numbers encoded within a bar code symbol.
DEPTH OF FIELD
The range between minimum and maximum distances at which a scanner can read a symbol with a certain minimum element width.
DISCRETE CODE
A bar code or symbol in which the spaces between characters (intercharacter gaps) are not part of the code (e.g., Code 39).
DISCRETE 2 OF 5
A binary bar code symbology representing each character by a group of five bars, two of which are wide. The location of wide bars in the group determines which character is encoded; spaces are insignificant. Only numeric characters (0 to 9) and START/STOP characters may be encoded.
EAN
European Article Number. This European/International version of the UPC provides its own coding format and symbology standards. Element dimensions are specified metrically. EAN is used primarily in retail. Main variants are EAN-8 and EAN-13.
EDGE ROUGHNESS
Edge irregularities as compared with a nominal bar edge.
ELEMENT
Generic term for a bar or space.
Glossary-4
Page 224
Glossary
ENCODED AREA
Total linear dimension occupied by all characters of a code pattern, including start/stop characters and data.
ERROR CORRECTION
In addition to error detection, the recovery capability of PDF417 over missing, destroyed, or misdecoded codewords. Error correction capability is based on the level of security (0 - 8) selected when the PDF417 label is printed.
EXTRANEOUS INK
Ink in a scan area not intended to be there (i.e., tracking and splatter).
FIRST READ RATE
Percentage of correct readings obtainable by one pass of a scanning device over a bar code.
FLASH
Derived from EEPROM, this is a type of memory that holds its content without power but must be erased in bulk, or in a “flash.” Typically, these memory chips are less expensive and provide higher bit densities.
GUARD BARS
The start, stop, and center delimiting bars of UPC and EAN symbols.
HOST COMPUTER
A computer that serves other terminals in a network, providing such services as computation, database access, supervisory programs, and network control.
INTERCHARACTER GAP
The space between two adjacent bar code characters in a discrete code.
INTERLEAVED BAR CODE
A bar code in which characters are paired together, using bars to represents the first character and the intervening spaces to represent the second.
INTERLEAVED 2 OF 5
A binary bar code symbology representing character pairs in groups of five bars and five interleaved spaces. Interleaving provides for greater information density. The location of wide elements (bar/spaces) within each group determines which characters are encoded. This continuous code type uses no intercharacter spaces. Only numeric (0 to 9) and START/STOP characters may be encoded.
Glossary-5
Page 225
LS 4800/4900 Product Reference Guide
LASER
An acronym for Light Amplification by Stimulated Emission of Radiation. The laser is an intense light source. Light from a laser is all the same frequency, unlike the output of an incandescent bulb. Laser light is typically coherent and has a high energy density.
LASER SPOT SIZE
The diameter of the spot of laser light scanning the bar code, as measured at a given distance from the bar code. Smaller spot sizes yield higher resolution but poorer depth of focus.
LED INDICATOR
A semiconductor diode (LED - Light Emitting Diode) used as an indicator, often in digital displays. The semiconductor uses applied voltage to produce light of a certain frequency determined by the semiconductor's particular chemical composition.
MIL
1 mil = 1 thousandth of an inch.
MINIMUM REFLECTANCE DIFFERENCE (MRD)
The difference in percentage between light reflected from spaces (RS) and light reflected from bars (RB). MRD = %RS - %RB.
MISREAD (Misdecode)
A condition which occurs when the data output of a reader or interface controller does not agree with the data encoded within a bar code symbol.
MODULE
The narrowest bar or space (unit of measure) in a code. The term is used by the Uniform Code Council in its description of UPC/EAN code; it is also used in the description of Code 128. Contiguous modules are used to form bars or spaces which are wider than one unit.
MODULE ASPECT RATIO
The ratio of height to width of the narrowest bar or space, or unit of measure, in a bar code.
NANOMETRE
A unit of measure used to define the wavelength of light. Equal to 10-9 metre.
NOMINAL
The exact (or ideal) intended value for a specified parameter. Tolerances are specified as positive and negative deviations from this value.
Glossary-6
Page 226
Glossary
NOMINAL SIZE
Standard size for a bar code symbol. Most UPC/EAN codes can be used over a range of magnifications (e.g., from 0.80 to 2.00 of nominal).
NUMBER SYSTEM CHARACTER
In the UPC/EAN code used in a retail application, the mandatory, first encoded character, after the left guard bars. The corresponding human readable character identifies the coded character and appears at the bottom left-hand margin of the symbol. The assigned system number corresponds to a usage category for the bar coded item.
ONE-DIMENSIONAL SYMBOLOGY
Symbologies which encode data only in a linear or horizontal dimension (X-dimension); the symbol’s vertical height (Ydimension) is redundant (e.g., UPC/EAN, Code 39).
OPACITY
The capacity for material to interfere with transmission of light.
OVERHEAD
The number of characters required for start, stop, and checking for a given symbol (in PDF417, also left and right row indicators and error correction codewords). For example, a one-dimensional symbol requiring start/stop and two check characters contains four characters of overhead. Thus, to encode three data characters, seven characters are required.
PARAMETER
A variable that can have different values assigned to it.
PARITY TYPE
A parity check bit is the most significant bit of each ASCII coded character. The parity should be set to help detect transmission errors. The parity should be set to match that of the receiving device. If even parity is selected, the parity bit has a value (0 or 1) to ensure that an even number of 1 bits are contained in the coded character. If odd parity is selected, the parity bit will have a value (0 or 1) to ensure that an odd number of 1 bits are contained in the coded character. If 0 parity is selected, the parity bit always will be set to 0. If 1 parity is selected, the parity bit always will be set to 1.
Glossary-7
Page 227
LS 4800/4900 Product Reference Guide
PDF417
A two-dimensional, or stacked, bar code symbology which can encode over one kilobyte of data per label and which represents data in the form of codewords (values 0 - 928). Each codeword consists of four bars and four spaces, for a total of 17 module widths; modules vary in width from one to six element widths. The symbology permits encoding up to 30 data columns and from 3 to 90 data rows. For ease of reading while still maintaining high data density, codewords are encoded in three mutually-exclusive encodation sets, or clusters, with the same cluster repeating sequentially each third row.
PERCENT DECODE
The average probability that a single scan of a bar code would result in a successful decode. In a well-designed bar code scanning system, that probability should approach near 100%.
PRINT CONTRAST SIGNAL (PCS)
Measurement of the contrast (brightness difference) between the bars and spaces of a symbol. A minimum PCS value is needed for a bar code symbol to be scannable. PCS = (RL RD) / RL, where RL is the reflectance factor of the background and RD the reflectance factor of the dark bars.
PROM
Acronym for Programmable Read Only Memory. An integrated circuit which can be programmed through special processes and accessed at random during normal operation. Reprogramming is possible, but only through processes such as ultraviolet light erasing and electrical rewriting of data.
PROTOCOL
For a specific signaling type, a set of recognized rules governing the format and timing of message exchange. Between data communications devices, this includes an exchange of predetermined signals arranged for both establishing connection and for disconnecting.
QUIET ZONE
A clear space, containing no dark marks, which precedes the start character of a bar code symbol and follows the stop character.
REFLECTANCE
Amount of light returned from an illuminated surface.
Glossary-8
Page 228
Glossary
RESOLUTION
The narrowest element dimension which can be distinguished by a particular reading device or printed with a particular device or method.
ROW INDICATORS
To help synchronize a PDF417 symbol’s structure, codewords which collectively indicate which row a particular one is, which is the left and right side of that row, how many rows are in the symbol, what security level is encoded in the symbol, and how many data columns are in the rows. Left Row Indicators occur in each row immediately after the Start pattern; Right Row Indicators occur in each row immediately before the Stop pattern.
SCAN
Search for a symbol to be optically recognized.
SCAN AREA
Area intended to contain a symbol.
SCANNER
An electronic device used to scan bar code symbols and produce a digitized pattern that corresponds to the bars and spaces of the symbol. Its three main components are: 1. Light source (laser or photoelectric cell) - illuminates a bar code. 2. Photodetector - registers the difference in reflected light (more light reflected from spaces). 3. Signal conditioning circuit - transforms optical detector output into a digitized bar pattern.
SELF-CHECKING CODE
A symbology that uses a checking algorithm to detect encoding errors within the characters of a bar code symbol.
SHOW-THROUGH
The generally undesirable property of a substrate that permits underlying markings to be seen.
SPACE
The lighter element of a bar code formed by the background between bars.
SPECULAR REFLECTION
The mirror-like reflection of light from a surface, which can “blind” a scanner.
SPOT SIZE
Size of the scanning aperture.
SPOTS
The presence of ink in a bar code's spaces or clear areas. These generally reduce the percent decode.
Glossary-9
Page 229
LS 4800/4900 Product Reference Guide
START/STOP CHARACTER
A pattern of bars and spaces that provides the scanner with start and stop reading instructions and scanning direction. The start and stop characters are the first and last encoded characters of a bar code.
SUBSTRATE
A foundation material on which a substance or image is placed.
SUBSTRATE SCATTERING
Optical phenomenon which causes bars to appear larger and spaces narrower than they are actually printed. It is caused by the scattering of incident light rays within the medium.
SYMBOL
A scannable unit that encodes data within the conventions of a certain symbology, usually including start/stop characters, quiet zones, data characters, and check characters.
SYMBOL ASPECT RATIO
The ratio of symbol height to symbol width.
SYMBOL HEIGHT
The distance between the outside edges of the quiet zones of the first row and the last row.
SYMBOL LENGTH
Length of symbol measured from the beginning of the quiet zone (margin) adjacent to the start character to the end of the quiet zone (margin) adjacent to a stop character.
SYMBOLOGY
The structural rules and conventions for representing data within a particular bar code type (e.g. UPC/EAN, Code 39).
SYMMETRIC BAR WIDTH GROWTH
Uniform growth of bars evenly distributed.
TOLERANCE
Allowable deviation from the nominal bar or space width.
TWO-DIMENSIONAL SYMBOLOGY
Designed for high information density and higher encoding capability than one-dimensional bar codes, a symbology which encodes data in both the horizontal (X-dimension) and vertical dimensions, usually in a “stacked” or multi-row arrangement.
UPC
Universal Product Code. A relatively complex numeric symbology. Each character consists of two bars and two spaces, each of which can be any of four widths. The standard symbology for retail food packages in the United States.
Glossary-10