Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 13 of 24

LS 4800/4900 Product Reference Guide, pages 121 to 130

Pages 121 to 130 of 239

The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-4804 and Symbol LS-4904

Page 121

LS 4800/4900 Product Reference Guide

Host Serial RTS Line State This parameter sets the default host serial RTS line state to either high or low. To select LOW RTS, scan the bar code below.

<FN3>1080040 Host: Low RTS

To select HIGH RTS, scan the bar code below.

<FN3>1080041 Host: High RTS

5-72

Page 122

Programming the LS 4800

Serial Response Timeout This parameter determines the maximum period allowed to elapse before the scanner assumes end of transmission. The delay period can range from 0 to 9.9 seconds. To set a serial (RS-232C) response timeout: 1. Scan the SERIAL RESPONSE TIMEOUT bar code below. 2. Scan two bar codes on the next page which represent the desired time-out. You must always scan two bar codes. 3. If you make an error, or wish to change your selection, scan CANCEL.

<FN3>3090020063 Serial Response Timeout

5-73

Page 123

LS 4800/4900 Product Reference Guide

Serial Response Timeout (Continued)

<FN3>A0

<FN3>A1

0

1

<FN3>A2

<FN3>A3

2

3

<FN3>A4

<FN3>A5

4

5

<FN3>A6

<FN3>A7

6

7

<FN3>A8

<FN3>A9

8

9

<FN3>ACancel

5-74

Page 124

Programming the LS 4800

Beep On <BEL> When this parameter is enabled, the scanner issues a beep when a <BEL> character is detected on the RS-232C serial data line. <BEL> is used to gain a user's attention to indicate an illegal entry or other important event. If this parameter is enabled and the system is in battery mode, a 100 ms delay is placed at the end of the decode transmission. Select whether to enable or disable this parameter.

<FN3>1080001

<FN3>1080000

Beep On <BEL> Character

Do Not Beep On <BEL> Character

Data Transmission - 7 or 8-Bit ASCII Data Format This parameter determines whether data transmissions occur in the 7-bit or 8-bit ASCII format. Select this parameter according to the requirement of the receiving device. The default value is 8-bit ASCII. Select either 7-bit or 8-bit ASCII format for RS-232C communications.

<FN3>2090707

<FN3>2090708

7-Bit

8-Bit

5-75

Page 125

LS 4800/4900 Product Reference Guide

Macro PDF Features This section discusses programmable Macro PDF features fully supported by the LS 4800. Macro PDF is a special feature for concatenating multiple PDF symbols into one file. The LS 4800 can decode symbols that are encoded with this feature, however, the 64K version cannot buffer large sets of macro PDF symbols.

Caution When printing, keep each Macro PDF sequence separate, for each sequence has unique identifiers. Do not mix bar codes from several Macro PDF sequences, even if they encode the same data. When scanning Macro PDF sequences, scan the entire Macro PDF sequence without interruption. If you scan a mixed sequence, you get two long low beeps (Lo Lo) for inconsistent file ID or inconsistent symbology error.

Caution When scanning macro PDF with battery-powered LS 4900 models, remember that the decoder must remain active throughout the session, which depletes battery power. For best results, make sure battery power is adequate, and scan the macro PDF sequence efficiently.

Before programming these special features, follow the physical setup instructions in Chapter 2, Setup. Then program the required generic decode and data transmission parameters using the bar codes on the following pages. Use the same programming method for setting Macro PDF features as used for standard features. Note that all parameter settings are stored in non-volatile memory and so are retained after powerdown.

5-76

Page 126

Programming the LS 4800

Macro PDF Transmit / Decode Mode Symbols Select only one of the four options below for handling the decoding of Macro PDF. !

Buffer All Symbols / Transmit Macro PDF When Complete: This activates transmission of all decode data from an entire Macro PDF sequence. Transmission does not occur until the entire Macro PDF sequence is scanned and decoded. This is the default option. If the decode data exceeds the limit of 9.5K bytes or more than 64 Macro PDF bar codes have been scanned, there is no transmission because the entire sequence has not been scanned, and an error occurs. Use the parameter Flush Macro PDF Buffer to purge the buffer.

!

Transmit Any Symbol in Set / No Particular Order: This causes transmission of data from each Macro PDF417 symbol as decoded, whether it is in sequential order or not. Up to 1024 Macro PDF bar codes may be transmitted.

!

Scan in Sequence Only / Transmit in Sequence Without Buffering: This causes transmission of data from each symbol within the Macro PDF sequence as decoded, provided the Macro PDF symbols are scanned in order. If you do not scan the symbols in order, an error occurs. Up to 1024 Macro PDF bar codes may be transmitted.

!

Buffer Scans Out of Order / Transmit Scans in Order: When enabled, decode data from each symbol within the Macro PDF sequence is transmitted when decoded, provided that the Macro PDF symbols are scanned in order. Decode data from symbols out of order in the Macro PDF sequence is buffered. The decoder can buffer up to 9.5K bytes or 64 Macro PDF bar codes. Use the parameter Flush Macro PDF Buffer to purge the buffer.

5-77

Page 127

LS 4800/4900 Product Reference Guide

Macro PDF Transmit / Decode Mode Symbols (Continued)

<FN3>20N0000 Buffer All Symbols / Transmit When Complete - Default

<FN3>20N0001 Transmit Any Symbol In Set / No Particular Order

<FN3>20N0002 Scan In Sequence Only / Transmit In Sequence Without Buffering

<FN3>20N0003 Buffer Scans Out Of Order/ Transmit Scans In Order

5-78

Page 128

Programming the LS 4800

Transmit Symbols in Codeword Format Enabling this activates transmission of each PDF symbol as directly decoded data codewords, whether that symbol is part of a macro PDF sequence or not. Note that data is output as codeword values, not as interpreted data. “Codeword values” is an ASCII representation of a number from 000 to 928 for each codeword, preceded by an escape character. This escape character is a backslash by default, but the user may change this value. For example, the codeword value 005 is sent to the host in the form of \005 for GLIs, and \C005C for ECIs. This output format is based on the AIM USA Uniform Symbology Specification for PDF417 (1994). All output codewords take up exactly 4 characters for GLIs and 6 characters for ECIs. However, there may be non-decodable characters in the PDF symbol, such as a GLI sequence. This special codeword sequence activates a certain kind of interpretation to the encoded data. Non-decodable codewords like GLIs are embedded in the output stream just like any other codeword, e.g., \927\001. Because GLIs are indistinguishable from other codewords in the output data stream, the host must intelligently recognize them as GLIs and process their interpretations. Note that when a macro PDF sequence is transmitted, the last character in the last block of data transmitted is always\922 (if selected). This indicates the end of that macro PDF transmission.

5-79

Page 129

LS 4800/4900 Product Reference Guide

Transmit Symbols in Codeword Format (Continued) Enable or disable by scanning the appropriate bar code.

<FN3>10M0001 Enable Transmit In Codeword Format

<FN3>10M0000 Disable Transmit In Codeword Format

5-80

Page 130

Programming the LS 4800

Escape Characters This enables the backslash (\) character as an Escape character for systems that can process transmissions containing special data sequences. Scan a bar code below to either format special data (e.g., GLI escapes, MacroPDF417 Control Block optional fields) according to the GLI (Global Label Identifier) protocol or the ECI (Extended Channel Interpretation) protocol, or to disable this parameter.

<FN3>20N0401 ECI Protocol

<FN3>20N0402 GLI Protocol

<FN3>20N0400 None

5-81