The text of a manual · part 11 of 24
LS 4800/4900 Product Reference Guide, pages 101 to 110
Pages 101 to 110 of 239
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-4804 and Symbol LS-4904
Page 101
LS 4800/4900 Product Reference Guide
Timeout Between Decodes (Continued)
<FN3>A0
<FN3>A1
0
1
<FN3>A2
<FN3>A3
2
3
<FN3>A4
<FN3>A5
4
5
<FN3>A6
<FN3>A7
6
7
<FN3>A8
<FN3>A9
8
9
<FN3>ACancel
5-52
Page 102
Programming the LS 4800
Security Options Decode UPC/EAN Supplemental Redundancy With Autodiscriminate UPC/EAN Supplementals selected, this option adjusts the number of times a symbol without supplementals is decoded before transmission. The range is from two to twenty times. Five or above is recommended when decoding a mix of UPC/EAN symbols with and without supplementals, and the autodiscriminate option is selected. To select a decode redundancy value: 1. Scan the bar code below. 2. Scan two bar codes on the next page which represent the desired value. Single digit numbers must have a leading zero. 3. If you make an error, or wish to change your selection, scan CANCEL.
<FN3>305182021E Decode UPC/EAN Supplemental Redundancy
5-53
Page 103
LS 4800/4900 Product Reference Guide
Decode UPC/EAN Supplemental Redundancy (Continued)
<FN3>A0
<FN3>A1
0
1
<FN3>A2
<FN3>A3
2
3
<FN3>A4
<FN3>A5
4
5
<FN3>A6
<FN3>A7
6
7
<FN3>A8
<FN3>A9
8
9
<FN3>ACancel
5-54
Page 104
Programming the LS 4800
Linear Code Type Security Level Note: Does not apply to Code 128. The LS 4800 offers four levels of decode security for linear code types (e.g., Code 39, Interleaved 2 of 5). Higher security levels are selected for decreasing levels of bar code quality. As security levels increase, the scanner’s aggressiveness decreases. Select the security level appropriate for your bar code quality.
Linear Security Level 1 The following code types must be successfully read twice before being decoded: Code Type
Length
Codabar
All
MSI Plessey
4 or less
D 2 of 5
8 or less
I 2 of 5
8 or less
<FN3>2051501 Linear Security Level 1
Linear Security Level 2 All code types must be successfully read twice before being decoded.
<FN3>2051502 Linear Security Level 2
5-55
Page 105
LS 4800/4900 Product Reference Guide
Linear Security Level 3 Code types other than the following must be successfully read twice before being decoded. The following codes must be read three times: Code Type
Length
MSI Plessey
4 or less
D 2 of 5
8 or less
I 2 of 5
8 or less
Codabar
8 or less
<FN3>2051503 Linear Security Level 3
Linear Security Level 4 All code types must be successfully read three times before being decoded.
<FN3>2051504 Linear Security Level 4
5-56
Page 106
Programming the LS 4800
Bi-directional Redundancy This parameter is only valid when a Linear Code Type Security Level has been enabled. When this parameter is enabled, a bar code must be successfully scanned in both directions (forward and reverse) before being decoded.
<FN3>1040311 Enable Bi-directional Redundancy
<FN3>1040310 Disable Bi-directional Redundancy
5-57
Page 107
LS 4800/4900 Product Reference Guide
UPC/EAN Security Level The LS 4800 offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are provided for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so be sure to choose only that level of security necessary for any given application. Select a UPC/EAN security level: !
UPC/EAN Security Level 0: This is the default setting which allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
!
UPC/EAN Security Level 1: As bar code quality levels diminish, certain characters become prone to mis-decodes before others (i.e., 1, 2, 7, 8). If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are limited to these characters, select this security level.
!
UPC/EAN Security Level 2: If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are not limited to characters 1, 2, 7, and 8, select this security level.
!
UPC/EAN Security Level 3: If you have tried Security Level 2, and are still experiencing misdecodes, select this security level. Be advised, selecting this option is an extreme measure against mis-decoding severely out of spec bar codes. Selection of this level of security significantly impairs the decoding ability of the scanner. If this level of security is necessary, you should try to improve the quality of your bar codes.
5-58
Page 108
Programming the LS 4800
UPC/EAN Security Level (Continued)
<FN3>2051100 UPC/EAN Security Level 0
<FN3>2051101 UPC/EAN Security Level 1
<FN3>2051102 UPC/EAN Security Level 2
<FN3>2051103 UPC/EAN Security Level 3
5-59
Page 109
LS 4800/4900 Product Reference Guide
RS-232 Options RS-232C Host Types This parameter selects an RS-232C host interface option. When you select a specific host, this automatically configures RS-232C parameters such as RS-232C protocol and code types to those of that specific host. See Table 5-4 and Table 5-5 for these automatically determined settings.
Table 5-4. Standard RS-232, Nixdorf Parameter
5-60
Std. RS-232
Nixdorf Mode A
Nixdorf Beetle
Xmit Code ID
No
Yes
Yes
Data Trans. Error
Data
Data/Suffix
Data/Suffix
Suffix
None
CR(1013)
CR(1013)
Baud Rate
9600
9600
9600
Parity
None
Odd
Odd
H/W Handshaking
None
None
RTS/CTS Opt. 3
S/W Handshaking
None
None
None
Serial Resp. T/O
2.0 Sec.
9.9 Sec.
9.9 Sec.
Stop Bit Select
One
One
One
ASCII Format
8-Bit
8-Bit
8-Bit
Beep on <BEL>
Disabled
Disabled
Disabled
RTS Line State
Low Always
Low Always
Low Always
Special Notes
None
None
Output 0x60 for all CR except last one
Page 110
Programming the LS 4800
RS-232C Host Types (Continued) Table 5-5. Fujitsu, ICL, PDT 3300 Parameter Xmit Code ID
Fujitsu
ICL
PDT 3300
Yes
Yes
Yes
Data Trans. Error
Data/Suffix
Data/Suffix
STX/Data/ETX/ LRC
Suffix
CR(1013)
CR(1013)
None
Baud Rate
9600
9600
9600
Parity
None
Even
Even
H/W Handshaking
None
RTS/CTS Opt. 3
RTS/CTS
S/W Handshaking
None
None
ACK/NAK
Serial Resp. T/O
2.0 Sec.
9.9 Sec.
9.9 Sec.
Stop Bit Select
One
One
One
ASCII Format
8-Bit
8-Bit
7-Bit
Beep on <BEL>
Disabled
Disabled
Disabled
RTS Line State
Low Always
High Always
Low Always
Special Notes
None
None
None
5-61