The text of a manual · part 8 of 19
LS 4071 Product Reference Guide: Chapter 5 Parameter Menus, pages 45 to 54
Pages 45 to 54 of 168, from LS 4071 Product Reference Guide
The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-4071
Page 45
Chapter 5 Parameter Menus Operational Parameters The LS 4071 is shipped with the default settings beginning on page 5-2. These default values are stored in non-volatile memory and are preserved even when the scanner is powered down. You can change these default values by scanning the appropriate bar codes included in this manual. These new values replace the standard default values in memory. The default parameter values can be recalled by scanning the SET ALL DEFAULTS bar code on page 5-7. Even if the default parameters suit your needs, you still must select a terminal type. The base automatically identifies the host type on power-up. It makes this determination provided the host is powered-up before the base is attached to it. You must then select the appropriate terminal type for that host. For example, if the base is connected to an IBM 4683, after you hear the power-up beeps, you must then select the proper port. The same applies to all other host types.
5-1
Page 46
LS 4071 Product Reference Guide
The following table lists the defaults for all parameters. If you wish to change any option, scan the appropriate bar code(s). Table 5-1. Default Table Parameter
Default
Page Number
Set Default Parameter
All Defaults
5-7
Host Type
See page 5-1
5-8
Beeper Tone
High Frequency
5-12
Beeper Volume
High
5-13
Laser On Time
3.0 seconds
5-14
Base Beep After Good Decode
Enable
5-15
Scanner Beep After Good Decode
Disable
5-16
Base Beep Type
Beep 1
5-17
Transmit “No Read” Message
Disable
5-18
1
5-19
Disable
5-22
UPC-A
Enable
5-23
UPC-E
Enable
5-23
EAN-8
Enable
5-24
EAN-13
Enable
5-24
Bookland EAN
Disable
5-25
Decode UPC/EAN Supplementals
Ignore
5-26
7
5-27
Linear Code Type Security Levels Bi-directional Redundancy UPC/EAN
Decode UPC/EAN Supplemental Redundancy
5-2
Page 47
Parameter Menus
Table 5-1. Default Table Parameter
Default
Page Number
Transmit UPC-A Check Digit
Enable
5-28
Transmit UPC-E Check Digit
Enable
5-28
UPC-A Preamble
System Character
5-29
UPC-E Preamble
System Character
5-30
Convert UPC-E to A
Disable
5-31
EAN-8 Zero Extend
Disable
5-32
Type is EAN-13
5-33
UPC/EAN Security Levels
0
5-34
UPC/EAN Coupon Code
Disable
5-36
Code 128
Enable
5-37
UCC/EAN-128
Disable
5-38
Code 39
Enable
5-40
Trioptic Code 39
Disable
5-41
Set Length(s) for Code 39
2 to 55
5-43
Code 39 Check Digit Verification
Disable
5-44
Transmit Code 39 Check Digit
Disable
5-45
Code 39 Full ASCII Conversion
Disable
5-46
Buffer Code 39
Disable
5-47
Convert Code 39 to Code 32
Disable
5-50
Convert EAN-8 to EAN-13 Type
Code 128
Code 39
5-3
Page 48
LS 4071 Product Reference Guide
Table 5-1. Default Table Parameter
Default
Page Number
Disable
5-51
4-55
5-52
Enable
5-54
14
5-55
I 2 of 5 Check Digit Verification
Disable
5-57
Transmit I 2 of 5 Check Digit
Disable
5-58
Convert I 2 of 5 to EAN 13
Disable
5-59
Disable
5-60
12
5-61
Disable
5-63
5-55
5-65
CLSI Editing
Disable
5-66
NOTIS Editing
Disable
5-67
Code 93 Code 93 Set Length(s) for Code 93 Interleaved 2 of 5 Interleaved 2 of 5 Set Length(s) for I 2 of 5
Discrete 2 of 5 Discrete 2 of 5 Set Length(s) for D 2 of 5 Codabar Codabar Set Lengths for Codabar
5-4
Page 49
Parameter Menus
Table 5-1. Default Table Parameter
Default
Page Number
Disable
5-68
Any Length
5-70
One
5-71
Transmit MSI Plessey Check Digit
Disable
5-72
MSI Plessey Check Digit Algorithm
Mod 10/Mod 10
5-73
None
5-75
0
5-76
7013 (<CR/LF> for serial)
5-77
Scan Data Transmission Format
Data as is
5-78
Transmit ASCII/Intermediate Data
ASCII Data
5-80
MSI Plessey MSI Plessey Set Length(s) for MSI Plessey MSI Plessey Check Digits
Data Options Transmit Code ID Character Pause Duration Prefix/Suffix Values
5-5
Page 50
LS 4071 Product Reference Guide
Table 5-1. Default Table Parameter
Default
Page Number
Standard
5-11
Baud Rate
9600
5-82
Parity
None
5-83
Check Receive Errors
Disable
5-85
Hardware Handshaking
None
5-87
Software Handshaking
None
5-89
Host Serial Response Time-out
2 Sec.
5-92
RTS Line State
Low
5-93
Stop Bit Select
1
5-94
ASCII Format
8-Bit
5-95
Beep on <BEL>
Disable
5-96
0
5-97
RS-232C RS-232 Host Type
Intercharacter Delay
5-6
Page 51
Parameter Menus
Set Default Parameter Scanning this bar code returns all parameters to the values listed in the default table beginning on page 5-2.
SET ALL DEFAULTS
5-7
Page 52
LS 4071 Product Reference Guide
Host Type IBM 46XX Host Types To select one of the following as a POS Interface, scan the appropriate bar code below. Note: To properly communicate with 468X/9X terminals, the driver corresponding to the port being used must be loaded and enabled when you are configuring your terminal system. See your terminal’s operating manual for details.
Port 5B
Port 9B
Port 17
5-8
Page 53
Parameter Menus
Host Type RS-232C Host Types Three RS-232C hosts are set up with their own parameter default settings. Selecting the ICL, Fujitsu or Nixdorf RS-232C terminal sets the defaults listed below. These defaults take precedence over Standard RS-232 defaults. So, if you’ve selected Fujitsu RS-232C, then select the Standard RS-232 defaults, the Fujitsu defaults still take precedence. To return to the factory set defaults, scan the SET ALL DEFAULTS bar code on page 5-7.
Table 5-2. Terminal Specific RS-232C Parameter
Standard
ICL
FUJITSU
NIXDORF Mode A/ Mode B
Transmit Code ID
No
Yes
Yes
Yes
Data Transmission Format
Data as is
Data/Suffix
Data/Suffix
Data/Suffix
Suffix
CR/LF
CR
CR
CR
Baud Rate
9600
9600
9600
9600
Parity
None
Even
None
Odd
Hardware Handshaking
None
RTS/CTS Option 3
None
RTS/CTS Option 3
Software Handshaking
None
None
None
None
Serial Response Time-out
2 Sec.
9.9 Sec.
2 Sec.
9.9 Sec.
Stop Bit Select
One
One
One
One
ASCII Format
8-Bit
8-Bit
8-Bit
8-Bit
Beep On <BEL>
Disabled
Disabled
Disabled
Disabled
RTS Line State
Low
High
Low
*Low = No data to send
*In the Nixdorf Mode B, if CTS is Low, transmission of scan data is disabled. When CTS is High, bar code data is transmitted to the host.
5-9
Page 54
LS 4071 Product Reference Guide
Host Type RS-232C Host Types Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal enables the transmission of Code ID Characters as listed below. These Code ID Characters are not programmable and are separate from the Transmit Code ID feature. The Transmit Code ID feature should not be enabled for these terminals.
Table 5-3. Terminal Specific Code ID Characters ICL
5-10
FUJITSU
NIXDORF
UPC-A
“A”
“A”
“A”
UPC-E
“E”
“E”
“C0”
EAN-8
“FF”
“FF”
“B”
EAN-13
“F”
“F”
“A”
Code 39
“C” <len>
None
“M”
Codabar
“N” <len>
None
“N”
Code 128
“L” <len>
None
“K”
I 2 of 5
“I” <len>
None
“I”
Code 93
None
None
“L”
D 2 of 5
“H” <len>
None
“H”
UCC/EAN 128
“L” <len>
None
“P”
MSI/Plessey
None
None
“O”
Bookland EAN
“F”
“F”
“A”
Trioptic
None
None
None