Page 19
Chapter 2 Set Up Unpacking Remove the scanner from its packing and inspect it for damage. If the scanner was damaged in transit, call the Symbol Support Center at one of the telephone numbers listed on page viii. KEEP THE PACKING. It is the approved shipping container and should be used if you ever need to return your equipment for servicing.
Setting Up the Base Station 1. Place the base station on a horizontal surface. Remember the scanner’s operating range is approximately 10 feet (3 meters). It is preferable to have the scanner and base station in line of sight. Placing the base station near any large metal mass (e.g., a filing cabinet) may interfere with scanner/base station communications. The base station may be placed on a shelf below a counter. This placement, however, may also result in less than optimum scanner/base station communications. 2. Connect an interface or adapter cable (for Synapse cables) to the base station. 3. If using a direct connect interface cable, it should be connected to the appropriate connector on the host. See Connecting to a Host on page 2-5.
Interface or Adapter Cable
Power Cable
Figure 2-1. Host and Power Cables
2-1
Page 20
LS 4071 Product Reference Guide
4. The Synapse adapter cables have a flying power lead. Connect this lead to the receptacle in the Synapse cable, as shown below. See the Synapse guide for details.
Synapse
Adapter Cable
Flying Power Lead
Figure 2-2. Synapse and Adapter Cable
5. Connect an appropriate power supply to the power receptacle on the base station. You will hear three beeps and the indicator light on the base station will blink, signifying successful power-up.
2-2
Page 21
Set Up
Charging the Battery Before its first use, the LS 4071 batteries must be charged. To do so: 1. Connect the power supply to the power input jack on the RL 47X base station. 2. Connect the power supply to a receptacle supplying AC power of the proper voltage level. 3. Insert the scanner into the base station, so that the nose of the scanner and tip of the handle seat into the receptacles.
Figure 2-3. Placing the Scanner into the Base Station
4. Check the charge status indicator light. See table on page 4-6. 5. The battery pack will fully charge within 2 hours. When fully charged, proceed with pairing, as described on page 2-4. As a charging stand, the base station recharges batteries in the scanner when the scanner is in the cradle. The status of the scanner battery module determines the charge rate. If the battery module is at or near full charge, the base station supplies a trickle charge. If the battery module is at less than full charge, there is a programmed charge. Note that the scanner can be removed from the base station at any time.
2-3
Page 22
LS 4071 Product Reference Guide
Battery Life When batteries begin to run down, the scanner emits 4 high tone beeps. You then have about 10 scans remaining. Although NiCad batteries are rechargeable, they do have a limited life. In typical applications, the batteries should last about two years. As they begin to age, batteries do not hold a charge as long as when they were fresh; you have to charge them more often. New battery packs can be obtained from Symbol Technologies. See your Symbol representative for more information.
Pairing the Scanner with the Base Station The wireless “connection” between the scanner and base is the low power radio transmission through an RF transmitter in the scanner, and an RF receiver in the base station. The actual communication consists of unidirectional message packets from the scanner to the base. However, the scanner and base station must be paired for this communication to work between the two devices. Each base station is assigned a unique address in the factory. To pair the scanner with the base station: • Scan the PAIRING bar code on the RL 47X base. The bar code is located in the well in which the scanner head rests. An additional pairing bar code can be found on the bottom of the base. • Successful pairing is indicated by a warble beep from the scanner, then the base. If either beep is not heard, the pairing was unsuccessful. The scanner and base should be configured with the same set of parameters. Scanning the bar code below ensures that the scanner’s parameters are sent to the base.
2-4
Page 23
Set Up
Connecting to a Host With some terminal types, the LS 4071 is unable to answer host terminal polls until the appropriate host type is selected. This may result in an error message generated by the host. To correct this situation, select the proper parameter set and initialize the host terminal. See Chapter 2 for more information.
RS-232C Plug the cable from the RL 474 base station into the appropriate port on the host device.
IBM 468X/9X Plug the SDL modular connector at the end of the selected cable from the RL 475 base station into the appropriate port (5B, 9B, 9C, 9E, or 17). Check that the connection is secure. Note that the unit may be connected to one hardware port, and configured for a different software port via the bar code menus on page 5-8. The hardware ports determine how the unit is connected to the host, while the software port configuration determines how it communicates. LS 4071
IBM 4683/84/93/94 Cash Register
Base
Figure 2-4. Typical System Configuration
2-5
Page 24
LS 4071 Product Reference Guide
IBM 468X/9X (Contd)
PORT 5B
PORT 9B
PORT 17
Figure 2-5. IBM 4683 Rear Panel With Cover Removed
9B
5B 17
Figure 2-6. IBM 4684 Rear Panel With Cover Removed
2-6
Page 25
Set Up
IBM 468X/9X (Contd)
5B
9C 9B
Figure 2-7. IBM 4693 Rear Panel With Cover Removed
PORT 9E
Figure 2-8. IBM 4694 Rear Panel With Cover Removed
Wand Emulation, OCIA, OCR, Keyboard Wedges See the instructions packed with the appropriate Synapse cable. Adapter cable required. See Figure 2-2.
2-7
Page 26
LS 4071 Product Reference Guide
2-8