Page 1 read from a scan by OCR; it may hold reading errors

LS 4, 0 0 0

Page 2

L S

4 0 0 0

© 2001 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license exists only for equipment, circuits, and subsystems contained in Symbol products. Symbol and the Symbol logo are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No. 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025; 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,947; 6,036,098; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297; 6,068,190; 6,082,621; 6,084,528; 6,088,482; 6,092,725; 6,101,483; 6,102,293; 6,104,620; 6,114,712; 6,115,678; 6,119,944; 6,123,265; 6,131,814; 6,138,180; 6,142,379; 6,172,478; 6,176,428; 6,178,426; 6,186,400; 6,188,681; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581; D414,171; D414,172; D418,500; D419,548; D423,468; D424,035; D430,158; D430,159; D431,562; D436,104. Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan). European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713. rev. 04/01

Page 3

Q u i c k

R e f e r e n c e

Scanning Made Easy The scanner should have already been installed and programmed. If not, consult the Product Reference Guide. If you need assistance, contact your local supplier or Symbol Techologies.

Installing the Cable 1. Switch off all devices connected to the LS 400X cable. 2. Pull the boot up over the cable until just the connector is protruding.

3. Plug the modular connector on the cable into the receptacle in the bottom of the LS 400X handle. Listen for a click.

4. Gently tug the cable to ensure the connector is properly secured. 1

Page 4

L S

4 0 0 0

5. Slide the boot up while observing its orientation until it is securely in place.

6. Make certain the semi-circular key on the boot slides inside the handle assembly, and that the boot snaps into place. 7. Gently pull the boot to make certain it is properly seated.

Switching Cables Different cables are required for different hosts. To change the scanner cable: 1. Slide boot down over cable. 2. Unplug modular connector by depressing connector clip (through the access hole), and remove existing cable. 3. Follow steps for Installing the Cable, beginning on page 1.

2

Page 5

Q u i c k

R e f e r e n c e

Ready, Test, Scan Ready Before you use the scanner, make sure all cable connections are secure.

Test Aim the scanner away from you. Press the trigger; the scan beam lights and a yellow light illuminates at the rear of the scanner.

Scan Make sure the bar code is in the correct scanning range. Aim and press the trigger. The scanner has read the symbol when: • • •

You hear a beep. The yellow light turns green. The laser turns off.

3

Page 6

L S

4 0 0 0

Aiming Hold at an angle Do not hold the scanner directly over the bar code. Laser light reflecting directly back into the scanner from the bar code is known as specular reflection. This strong light can “blind” the scanner and make decoding difficult. The area where specular reflection occurs is known as a “dead zone”. You can tilt the scanner up to 65 ° forward or back and achieve a successful decode. Simple practice quickly shows what tolerances to work within.

Successful Scanning

Successful Scanning

Possible Specular Reflection

65

65

4

4

Page 7

Q u i c k

R e f e r e n c e

Aiming Scan the Entire Symbol • • •

The scan beam must cross every bar and space on the symbol (as in the left bar code below). The larger the symbol, the farther away you should hold the scanner. Hold the scanner closer for symbols with bars that are close together. Right Wrong

Note:

LS 4000 series scanners require no user maintenance.

What Does The Beep Mean? When you hear 1 beep (short high tone) it means data has been decoded successfully. If any other beeps are heard, contact the technical person in charge of scanning.

5

Page 8

L S

4 0 0 0

What If... nothing happens when you follow the operating instructions? • • • •

Check the system power. Check for loose cable connections. Be sure the scanning system is programmed to read the type of bar code you are trying to scan. Check to be sure the symbol is not defaced.

6

Page 9

G u i d e u t i l i s a t e u r

La lecture des codes à barres simplifieé Installez et programmez d’abord le lecteur. Si tel n’est pas le cas, reportez-vous au Guide de référence produit. En cas de problème, contactez votre revendeur local ou Symbol Technologies.

Installation du câble 1. Eteignez tous les appareils qui sont connectés au câble du LS 400X. 2. Faites glisser l’isolateur le long du câble jusqu’à ce que le connecteur soit le seul élément qui dépasse.

3. Branchez le connecteur modulaire du câble dans la prise située sur la partie inférieure de la poignée du LS 400X jusqu’à ce qu’il s’enclenche avec un déclic.

4. Tirez doucement sur le câble pour vous assurer que le connecteur est bien fixé. 7

Page 10

L S

4 0 0 0

5. Déplacez l’isolateur tout en observant sa direction, jusqu’à ce qu’il s’enclenche.

6. Veillez à ce que la clé semi-circulaire del’isolateur glisse à l‘interieur de la poignee et que l’isolateur s’enclenche. 7. Tirez doucement l’isolateur pour vérifier s’il est bien en place.

Changement de câbles Il faut un câble adapté à chaque système central. Pour changer le câble du lecteur : 1. Coulissez l’isolateur vers le bas le long du câble. 2. Débranchez le connecteur modulaire en appuyant sur l’attache connecteur (à travers le trou d’accès) et retirez le câble. 3. Suivez la procédure d’installation du câble, à partir de la page 7.