Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 25

LS 3070 Product Reference Guide: Chapter 5 Interface Guide, pages 48 to 55

Pages 48 to 55 of 214, from LS 3070 Product Reference Guide

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-3070

Page 48

LS 3070 Product Reference Guide: Interface Guide

Connector

Printer Ground Strap

Figure 5-7. Disconnecting Cable from Connector

Locking Tab

Figure 5-8. Sliding Printer Locking Tabs 5-9

Page 49

LS 3070 Product Reference Guide: Interface Guide

Figure 5-9. Cable

Figure 5-10. J16 Connector 5-10

Page 50

LS 3070 Product Reference Guide: Interface Guide

Figure 5-11. Connecting J2 to J16

Figure 5-12. Securing J1

5-11

Page 51

LS 3070 Product Reference Guide: Interface Guide

IBM 3653 Installation 1. Be sure the IBM 3653 terminal is powered-down. Open the door over the ribbon cartridge as shown in Figure 5-13. 2. Loosen the right side panel screw (see Figure 5-13). Grasp the right panel at top of the rear corner; pull out to the side and push back to remove the panel. 3. Loosen the two screws behind the top of the keyboard cover. Lift and remove the keyboard cover. See Figure 5-14. 4. From the bottom of the register, slide the cable retaining clips until the cables are free. From inside the register, pass the base station cable (single end) through the power cable hole. See Figure 5-15.

Caution Use extreme care to avoid damaging the connector pins. 5. Loosen the screw on the base of the cash register near the bottom left side of the card cage. Swing the card cage open by pulling on the left side. See Figure 5-16. 6. Locate the keyboard connector to check for 5 volts DC. Using a DVM, connect the GND (-) probe to the screw that holds the keyboard to the chassis, and connect the POS (+) probe to the 5-volt lead on the TOP ROW of the keyboard connector, second from right (see Figure 5-17). Turn on the cash register. If the voltage is less than 5 volts, locate the voltage adjustment hole on the power supply case behind the card cage (see Figure 5-18). Using a flexible screw driver, adjust the potentiometer until the voltage is 5.0 to 5.1 volts. Turn off the register and remove the DVM. 7. Route cable under card cage to the front of the register. 8. Locate the keyboard connector on the keyboard and observe its orientation while removing the connector. 9. Place shrink sleeve over the cable assembly (heat with blow dryer or heat gun to shrink the sleeving if possible). 10. Insert the polarizing key into the top right corner socket. The polarizing key is found in the bag containing the tie wrap. 5-12

Page 52

LS 3070 Product Reference Guide: Interface Guide

11. Remove the protective foam from the register end of the base station Ycable, and insert into the cable assembly. Place the assembly near the bottom of the register behind the keyboard. 12. Install the keyboard connector, as shown in Figure 5-19. Secure with the tie wrap that doesn't have a mounting hole. 13. Locate the brass plate behind the card cage and remove the front left screw. Install tie wrap between the screw and plate. Replace the screw and tighten. 14. Loop tie wrap around the cable. Insert in slot and pull tight. 15. Close the card cage and tighten the screws. 16. Replace the keyboard cover and side panel, then tighten the screws. You can now attach your scanner and peripheral devices.

Figure 5-13. Removing Panel

5-13

Page 53

LS 3070 Product Reference Guide: Interface Guide

Screws

Figure 5-14. Removing Keyboard Cover

Figure 5-15. Sliding Base Station Cable Through Hole

5-14

Page 54

LS 3070 Product Reference Guide: Interface Guide

Figure 5-16. Opening Card Cage

Figure 5-17. Connecting Probes 5-15

Page 55

LS 3070 Product Reference Guide: Interface Guide

Figure 5-18. Voltage Adjustment Hole

Figure 5-19. Installing Keyboard Connector

5-16