The text of a manual · part 5 of 25
LS 3070 Product Reference Guide: Chapter 4 Maintenance and Specifications
Pages 30 to 39 of 214, from LS 3070 Product Reference Guide
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-3070
Page 30
Chapter 4 Maintenance and Specifications Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. • Do not allow any abrasive material to touch the window. • Remove any dirt particles with a damp cloth. • Wipe the window using a tissue moistened with ammonia/water. • Do not spray water or other cleaning liquids directly into the window.
Recharging the Battery As a charging stand, the base/charger recharges batteries in the scanner when the scanner is in the cradle. The status of the scanner battery module determines the charge rate. If the battery module is at full charge, the base/ charger supplies a trickle charge. If the battery module is at less than full charge, there is a programmed charge. Note that the scanner can be removed from the base/charger at any time. When necessary, recharge the batteries. To do so: • Connect the power supply to the power input port on the front panel of the RL 470 base/charger, as illustrated below. • Connect the power supply to a receptacle supplying AC power of the proper voltage level. • Then place the scanner into the base/charger cradle, so that the nose of the scanner and tip of the handle fit snugly into the receptacles. Check the charge status indicator (blinking = fully charged) for full charge, which occurs within two hours. However, the scanner can be used on less than full charge.
4-1
Page 31
LS 3070 Product Reference Guide: Maintenance and Specifications
Power Supply Connection Port
Figure 4-1. Recharging the LS 3070
Changing Battery Packs You can charge battery packs on the Universal Four Slot Battery Charger so that a charged battery pack is available when needed. In this case, simply remove the depleted battery pack and replace it with a freshly charged one. User instructions are in the Universal Four-Slot Battery Charger Quick Reference Guide.
4-2
Page 32
LS 3070 Product Reference Guide: Maintenance and Specifications
1. Remove Lower Handle from Scanner. Using a probe, press in the release button on the handle, as indicated at the right. With button pressed in below the outer housing, slide the battery pack out from the handle. Release Button
Four Slot Charger with Charging Adapter
LS 3070 Battery Pack
Figure 4-2. Changing LS 3070 Battery Packs
2. Insert Charged Battery Pack in Handle. With release button down, slide charged battery pack up into handle until it locks into place and the release button pops up into place as well.
4-3
Page 33
LS 3070 Product Reference Guide: Maintenance and Specifications
Charge Status LED Indications On the base/charger, there is a red LED indicator which uses flashing patterns to indicate the current charger status. The red Charge Status LED indicates the following conditions: • RED LED OFF, The scanner is not properly inserted or the battery is not functioning properly. • RED LED blinking slowly (1/8 sec. ON, 3/8 sec. OFF), Battery charge is pending. This can occur if the batttery temperature is too high or low or if the battery is deeply discharged. After several minutes, normal charging should begin. • RED LED ON, The battery is actively charging. Charging will complete in less than 2 hours. • RED LED blinking rapidly (1/8 sec. ON, 1/8 sec. OFF), Battery charging is complete.
4-4
Page 34
LS 3070 Product Reference Guide: Maintenance and Specifications
Accessories Standard Accessories Part Number
Description
RL 470
Base/interface charger
Base/Charger Cable:
Cables are available for most applications. See the Electronic ProductOrdering Guide for more information.
70-10294-01
LS 3070 Product Reference Guide
70-10538-01
LS 3070 Advanced Programmer’s Guide
70-10294-01Q
LS 3070 Series Quick Reference Guide
50-04000-041
117 V Power Supply
50-04000-040
220 V Power Supply
50-04000-037
100 V Power Supply
Optional Accessories Optional accessories, listed in the Electronic Product Ordering Guide, include various rechargers, magstripe readers, stands, and holders, which are supplied at extra cost. Additional units of standard accessories listed above may also be purchased at extra cost.
4-5
Page 35
LS 3070 Product Reference Guide: Maintenance and Specifications
LS 3070 Standard Technical Specifications ITEM Power Requirements: Scanner Base/Charger
DESCRIPTION 4.75 to 14 VDC; 210 mA @ 5 VDC Typical. 5 VDC ± 10% @ 190 mA Typical. 12 VDC ± 10% @ 400 mA Typical.
Scan Repetition Rate
Approximately 36 (± 3) scans/sec (bidirectional)
Start-up Time
<50 msec. from scan enable
Data Acquisition Time
<110 msec. from scan enable
Skew Tolerance
± 65° from normal
Pitch Angle
± 55° from normal
Decode Depth of Field
See LS 3070 Standard Range on page 3-6
Minimum Element Width
0.005 in.
.127 mm
Maximum Element Width
0.2 in.
5.08 mm
Print Contrast Minimum
20% absolute dark/light reflectance differential, measured at 675 nm.
Ambient Light Immunity Artificial Lighting Sunlight
450 ft. candles 8000 ft. candles
Durability
6-ft. drop to concrete
Operating Temperature
0° to 40°C
32° to 104°F
Storage Temperature
-40° to 60°C
-40° to 140°F
Humidity
5% to 95% (non-condensing)
Height
6.3 in.
16 cm
Length
5 in.
12.7 cm
Width
2.8 in.
7.1 cm
CDRH Class
I, II
4-6
4844 lux 86112 lux (@8 in. on low density bar codes)
Page 36
LS 3070 Product Reference Guide: Maintenance and Specifications
LS 3070LR Technical Specifications ITEM Power Requirements: Scanner Base/Charger
DESCRIPTION
Scan Repetition Rate Start-up Time
Approximately 36 (± 3) scans/sec (bidirectional) <50 msec. from scan enable
Data Acquisition Time
<110 msec. from scan enable
Skew Tolerance
± 60° from normal
Pitch Angle
± 45° from normal
Decode Depth of Field
See LS 3070LR Long Range on page 3-7
Minimum Element Width
0.007 in.
.178 mm
Maximum Element Width
0.2 in.
5.08 mm
Print Contrast Minimum
50% absolute dark/light reflectance differential, measured at 675 nm.
4.75 to 14 VDC; 210 mA @ 5 VDC Typical. 5 VDC ± 10% @ 190 mA Typical. 12 VDC ± 10% @ 400 mA Typical.
Ambient Light Immunity Incandescent Fluorescent Sodium Vapor Mercury Vapor Sunlight Durability
450 ft. candles 4844 lux 450 ft. candles 4844 lux 450 ft. candles 4844 lux 450 ft. candles 4844 lux 8000 ft. candles 86112 lux 6-ft. drop to concrete
Operating Temperature
0° to 40°C
32° to 104°F
Storage Temperature
-40° to 60°C
-40° to 140°F
Humidity
5% to 95% (non-condensing)
Height
6.3 in.
16 cm
Length
5 in.
12.7 cm
Width
2.8 in.
7.1 cm
CDRH Class
II 4-7
Page 37
LS 3070 Product Reference Guide: Maintenance and Specifications
LS 3070ALR Technical Specifications ITEM Power Requirements: Scanner Base/Charger
DESCRIPTION
Scan Repetition Rate Start-up Time
Approximately 36 (± 3) scans/sec (bidirectional) <50 msec. from scan enable
Data Acquisition Time
<110 msec. from scan enable
Skew Tolerance
± 60° from normal
Pitch Angle
± 45° from normal
Decode Depth of Field
See LS 3070ALR Advanced Long Range on page 3-8
Minimum Element Width
0.015 in.
.380 mm
Maximum Element Width
0.1 in.
2.54 mm
Print Contrast Minimum
50% absolute dark/light reflectance differential, measured at 675 nm.
4.75 to 14 VDC; 210 mA @ 5 VDC Typical. 5 VDC ± 10% @ 190 mA Typical. 12 VDC ± 10% @ 400 mA Typical.
Ambient Light Immunity Incandescent Fluorescent Sodium Vapor Mercury Vapor Sunlight
450 ft. candles 450 ft. candles 450 ft. candles 450 ft. candles 8000 ft. candles
Durability
6-ft. drop to concrete
Operating Temperature
0° to 40°C
32° to 104°F
Storage Temperature
-40° to 60°C
-40° to 140°F
Humidity
5% to 95% (non-condensing)
Height
6.3 in.
16 cm
Length
5 in.
12.7 cm
Width
2.8 in.
7.1 cm
CDRH Class
IIIA
4-8
4844 lux 4844 lux 4844 lux 4844 lux 86112 lux
Page 38
LS 3070 Product Reference Guide: Maintenance and Specifications
LS 3070XLR Technical Specifications ITEM Power Requirements: Scanner Base/Charger
DESCRIPTION 4.75 to 14 VDC; 210 mA @ 5 VDC Typical. 5 VDC ± 10% @ 190 mA Typical. 12 VDC ± 10% @ 400 mA Typical.
Scan Repetition Rate
Approximately 36 (± 3) scans/sec (bidirectional)
Start-up Time
<50 msec. from scan enable
Data Acquisition Time
<110 msec. from scan enable
Skew Tolerance
± 60° from normal
Pitch Angle
± 45° from normal
Decode Depth of Field
See LS 3070XLR Extra Long Range on page 3-9
Minimum Element Width
0.030 in.
.762 mm
Maximum Element Width
0.1 in.
2.54 mm
Print Contrast Minimum
50% absolute dark/light reflectance differential, measured at 675 nm.
Ambient Light Immunity Incandescent Fluorescent Sodium Vapor Mercury Vapor
100 ft. candles 450 ft. candles 450 ft. candles 450 ft. candles
Durability
6-ft. drop to concrete
Operating Temperature
0° to 40°C
32° to 104°F
Storage Temperature
-40° to 60°C
-40° to 140°F
Humidity
5% to 95% (non-condensing)
Height
6.3 in.
16 cm
Length
5 in.
12.7 cm
Width
2.8 in.
7.1 cm
CDRH Class
IIIA 4-9
1076.4 lux 4844 lux 4844 lux 4844 lux
Page 39
LS 3070 Product Reference Guide: Maintenance and Specifications
LS 3070HV Technical Specifications ITEM Power Requirements: Scanner Base/Charger
DESCRIPTION
Scan Repetition Rate
Approximately 36 (± 3) scans/sec (bidirectional)
Start-up Time
<50 msec. from scan enable
Data Acquisition Time
<110 msec. from scan enable
Skew Tolerance
± 60° from normal
Pitch Angle
± 45° from normal
Decode Depth of Field
See LS 3070HV High Visibility on page 3-10
Minimum Element Width
0.0075 in.
.190 mm
Maximum Element Width
0.1 in.
2.54 mm
Print Contrast Minimum
25% absolute dark/light reflectance differential, measured at 675 nm.
4.75 to 14 VDC; 210 mA @ 5 VDC Typical. 5 VDC ± 10% @ 190 mA Typical. 12 VDC ± 10% @ 400 mA Typical.
Ambient Light Immunity Incandescent Fluorescent Sodium Vapor Mercury Vapor Sunlight
400 ft. candles 4305 lux 450 ft. candles 4844 lux 450 ft. candles 4844 lux 450 ft. candles 4844 lux 10,000 ft. candles 107640 lux
Durability
6-ft. drop to concrete
Operating Temperature
0° to 40°C
32° to 104°F
Storage Temperature
-40° to 60°C
-40° to 140°F
Humidity
5% to 95% (non-condensing)
Height
6.3 in.
16 cm
Length
5 in.
12.7 cm
Width
2.8 in.
7.1 cm
CDRH Class
IIIA 4-10