Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 25

LS 3070 Product Reference Guide: Chapter 2 Setup

Pages 13 to 19 of 214, from LS 3070 Product Reference Guide

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-3070

Page 13

Chapter 2 Setup Unpacking Remove the LS 3070, the RL 470 base/charger unit, and the host interface cable from its packing and inspect each for evidence of physical damage. If any equipment was damaged in transit, call the Symbol Support Center at the number in the front matter. KEEP THE PACKING. It is the approved shipping container and should be used if you ever need to return your equipment for servicing.

Connecting the Cable to the Base/Charger Unit The cable connects to the base/charger in the same way but to each host terminal differently. For complete details per terminal type, refer to the RL 470 Base Station Interface Guide.

Installation Tip, Optimizing RF Performance The LS 3070 scanning system is equipped with a low power 2.4 Ghz radio. Depending on environmental conditions, the LS 3070 can have an RF transmission range of 30 - 50 feet (9 - 15 meters). Where environmental objects affect RF range and performance, do the following when you install the LS 3070 scanning system. This will help assure peak performance.

2-1

Page 14

LS 3070 Product Reference Guide: Setup

The RL 470 base station is a charger, host interface, and, significantly, receiving station for RF transmission. Therefore, do not install the RL 470 inaccessibly under a table or buried in a desk drawer. At a minimum, mount the RL 470 on a table or desk top. For optimum RF performance, especially in difficult environments, mount the RL 470 on a wall as high as possible. But keep in mind the limits of interface cable length and charging accessibility. Proper base positioning gives you the best possible range and coverage performance from the LS 3070 cordless scanning system.

Inserting the Scanner Into and Removing Scanner from Base/Charger To insert the scanner into the base/charger: 1. First, place the nose to the scanner into the large rectangular receptacle of the base/charger. 2. Then place the scanner handle into the opening of the smaller, latched receptacle and press down firmly until the bottom of the handle seats snugly into the receptacle and engages the latch.

Caution Use of excessive force in placing the scanner into the base can damage the charging contacts on the shoe of the scanner or in the receptacle of the base. Such damage can interfere with or prevent charging of the scanner’s batteries by the base. 3. To remove the scanner from the base/charger, grasp the handle of the scanner and lift the bottom of the handle out of the latched receptacle, thereby freeing the scanner from the base.

Caution It is important to remove the scanner handle-first. Trying to remove the scanner nose-first can break latch in the base receptacle .

2-2

Page 15

LS 3070 Product Reference Guide: Setup

Charging the Battery Before its first use, the LS 3070 batteries must be charged. To do so: • Connect the power supply to the power input port on the front panel of the RL 470 base/charger, shown in Figure 1-3: RL 470 Base/Charger Unit on page 1-4. • Connect the power supply to a receptacle supplying AC power of the proper voltage level. • Then insert the scanner into the base/charger cradle, so that the nose of the scanner and tip of the handle fit snugly into the receptacles. Check the charge status indicator (blinking = fully charged) for full charge, which occurs within two hours. When fully charged, proceed with pairing.

Pairing the Scanner with the Base/Charger The wireless “connection” between the two is the low power radio transmission through RF transceivers in the both the scanner and base/ charger. The actual communication consists of bidirectional message packets. However, the scanner and base/charger must be paired for this communication to work between the two devices.

Assigning Address to Base/Charger First, the base/charger must be assigned an address, with a value between 01 and 7E. Each base station must have a unique address.

2-3

Page 16

LS 3070 Product Reference Guide: Setup

Note: When setting the address of the base, you automatically set the initial frequency on which the base and the scanner communicate. In order to minimize possible interference between systems, bases which are close to each other should be assigned sequential addresses. Set the address through setting two rotary dials, located by opening a panel on the base/charger’s underside. Turn the base/charger upside down, open the panel, and notice two rotary dials. Insert Screwdriver in Slot Switch Panel

Base/Charger Underside

0

0

High Order 10 Position

Low Order 16 Position

Rotary Switches

The first is a 10-position (0 to 9, high order address digit) and the second a 16position (0 to F, low order address digit). Digits are printed sequentially around each circle. Do not use positions 8 and 9. Setting the 10-position switch to 8 or 9 will result in an error beep (5 long low tones) during pairing. Set the desired address with a small screwdriver; possible addresses are listed on the next page. Note that too large a screwdriver can damage the dials. When the address is set, close the panel, turn the base/charger rightside up again.

2-4

Page 17

LS 3070 Product Reference Guide: Setup

Possible Base/Charger Addresses 01

02 03

04

05

06

07

08

09

0A 0B 0C 0D 0E 0F

10

11

12 13

14

15

16

17

18

19

1A 1B 1C 1D 1E 1F

20

21

22 23

24

25

26

27

28

29

2A 2B 2C 2D 2E 2F

30

31

32 33

34

35

36

37

38

39

3A 3B 3C 3D 3E 3F

40

41

42 43

44

45

46

47

48

49

4A 4B 4C 4D 4E 4F

50

51

52 53

54

55

56

57

58

59

5A 5B 5C 5D 5E 5F

60

61

62 63

64

65

66

67

68

69

6A 6B 6C 6D 6E 6F

70

71

72 73

74

75

76

77

78

79

7A 7B 7C 7D 7E

Note: Each base station must have a unique address.

Pairing Scanner with Base/Charger To pair the scanner with the base/charger: • Scan the PAIRING bar code below or the bar code on the RL 470 base.

PAIRING • Then insert the scanner into the base/charger’s cradle. You have 15 seconds to do this, or there will be error beeps (4 beeps = unsuccessful pairing or base not powered). Note that you cannot scan data until this pairing is complete.

2-5

Page 18

LS 3070 Product Reference Guide: Setup

• At that time, through the scanner’s contact shoe, there is an exchange of information (addressing, RF channels, etc.) between the scanner and the base/charger’s cradle. This occurs in less than a second. • After that exchange, the scanner and base/charger are paired. Successful pairing is indicated by a warble beep; failure, or unsuccessful link, is indicated by a Lo Lo Lo Lo beep.

Setting Transmission Frequency Each scanner/base pair communicates on one of a number of channel frequencies, which varies by country. In most countries, there are 80 available channels (numbered 2 through 81); in France, there are only 9 channeles (numbered 46 through 54). The initial transmission frequency is determined by the base’s unique address, so neighboring LS 3070 systems operate on different channels. This allows them to transmit simultaneously without interfering with each other. Channel separation is optimal between sequential base addresses, so base units closest to each other should be assigned sequential base addresses if possible. (Note that data is transmitted between a scanner and base so quickly that a number of different LS 3070 systems can normally operate on the same channel without noticeable interference.)

2-6

Page 19

LS 3070 Product Reference Guide: Setup

Occasionally, there can be excessive interference on a channel from some other source of radio transmissions. In this case, the default channel of a system can be changed using the parameter codes for Set Transmission Frequency. If you find a particular scanner/base pair has trouble communicating over a normal operating distance, try setting different transmission frequencies to see if performance improves. (The LS 3070 system changes channels automatically if it encounters interference as much as 80% of the time over a continuous 5minute period.) Note: To set trasmission frequency correctly, be sure to use the correct Select Channel Number bar code for your country, and to set a channel within the allowable range.

Installing a Magstripe Reader If desired, install a magstripe reader. This may be done before or after pairing. 1. Remove the blank plug in the magstripe connection port on the base/ charger, and then plug the magstripe reader’s cable into this port, as illustrated below. 2. The purpose of the blank plug is to protect the base/charger from accidental damage that can be caused by static electrical discharge into the magstripe connection port. Keep this plug in the port whenever the magstripe reader is not connected.

Magstripe Reader Connection Port

2-7