What If... Nothing happens when you follow the operating instructions You Should • • • • • • • • •
Check that the correct power supply is attached to the base/ charger. Check for correct host interface cable or loose cable connections at the base/charger and host device. Make sure the device is programmed to read the type of bar code you want to scan. Check the scanner’s battery pack. Check the symbol to make sure it is not defaced. Try scanning similar symbols of the same code type. Check that the gas tank is not exhausted.* Make sure the scanner and base/charger have been successfully paired. Be sure you’re within the proper scanning and transmission range (30 to 50 ft., or 9 - 15 meters).
You get frequent communication errors (6 beeps after decode) • •
Check that you are within transmit range. Check that the scanner is successfully paired with the base/ charger.
35
Page 38
L S
3 0 7 0
S c a n n e r
You get frequent communication errors (6 beeps after decode): •
Check that the base/charger is powered up and that its cable connections are secure. Note: If after performing these checks the symbol still does not scan, contact your distributor or call the Symbol Support Center. * The gas tank limits the amount of time the laser remains on within a given period.
Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. • • • •
Do not allow any abrasive material to touch the window. Remove any dirt particles with a damp cloth. Wipe the window using a tissue moistened with ammonia/ water. Do not spray water or other cleaning liquids directly into the window.
36
Page 39
Q u i c k
R e f e r e n c e
Default Table Parameter
Default
Host Interface
See Set Host Type
Code Types
All
Code Lengths Code 39
1 to 55
Code 128
3 to 55
Codabar
2 to 55
I 2 of 5
14
D 2 of 5
14
MSI Plessey
1 to 55
Decode Options Transmit UPC-A Check Digit
Enabled
Transmit UPC-E Check Digit
Enabled
Convert UPC-E to UPC-A
Disabled
EAN Zero Extend
Disabled
Transmit No Decode Message
Disabled
Decode UPC/EAN Supplemental
Disabled
ITF-14/EAN-13 Conversion
Enabled
Transmit Code 39 Check Digit
Disabled
MSI Plessey Check Digit
One
Buffer Code 39
Disabled
Beeper Volume
High
Beep After Good Decode
Enabled
*Prefix/Suffix values only apply when the selected transmission format utilizes them. For example, if you select the default setting for Scan Data Transmission Format (Data As Is), any prefix or suffix selected will not be recognized, since the format requires neither.
37
Page 40
L S
3 0 7 0
S c a n n e r
Parameter
Default
UPC/EAN Security Level
0
Decode Redundancy
0
UPC-A Preamble
System Character
UPC-E Preamble
System Character
Pause Duration
0
Prefix/Suffix Values*
7013 (<Enter> for wedges, <CR/LF> for serial devices)
Magstripe Data Transmission Format
Data as is
Scan Data Transmission Format
Data as is
Laser Control Laser On Time-out
3 Sec
RS-232C Options Baud Rate
9600
Parity
Odd
Check Parity
Enabled
Hardware Handshaking
None
Software Handshaking
None
Serial Response Time-out
2.0 Sec
Stop Bit Select
Two
ASCII Data Format
7 Bit
RTS Line State
Low
Intercharacter Delay
0
Transmit Code ID Character
Disabled
*Prefix/Suffix values only apply when the selected transmission format utilizes them. For example, if you select the default setting for Scan Data Transmission Format (Data As Is), any prefix or suffix selected will not be recognized, since the format requires neither.
38
Page 41
Q u i c k
R e f e r e n c e
Parameter
Default
Transmit AIM Code ID
Disabled
Ignore Unknown Characters
Enabled
OCIA Transmit Time-out
3 Sec
OCIA Clock Polarity
Falling
NCR 2152 Fast Transmit
Disabled
IBM 4683/4 Magstripe Communications
Enabled
International Keypad Emulation
Disabled
International Keypad Emulation Fast Xmit
Disabled
National Keyboard Type
U.S. English
Set Transmission Frequency (Channel)
50
Wait for Host Interface Response Time
00
*Prefix/Suffix values only apply when the selected transmission format utilizes them. For example, if you select the default setting for Scan Data Transmission Format (Data As Is), any prefix or suffix selected will not be recognized, since the format requires neither.
Terminal Specific RS-232C Defaults Two RS-232C hosts are set up with their own parameter default settings. Selecting the ICL or Nixdorf RS-232C terminal will set the defaults listed below. These defaults take precedence over standard defaults. So, if you’ve selected Nixdorf RS-232C, then select the standard defaults, the Nixdorf defaults will still take precedence. Parameter Fixed Host Select
Standard No Host
ICL
Nixdorf
RS-232C
RS-232C
Transmit Code ID
No
Yes
Yes
Data Transmission Format
Data as is
Data/Suffix
Data/Suffix
39
Page 42
L S
3 0 7 0
Parameter Suffix
S c a n n e r
Standard CR/LF (7013)
ICL
Nixdorf
CR (1013)
CR (1013)
Baud Rate
9600
9600
9600
Parity
Even
Even
Odd
Check Parity
Enabled
Enabled
Enabled
Hardware Handshaking
None
None
None
Software Handshaking
None
None
None
Serial Response Time-out
2 Sec.
2 Sec.
2 Sec.
Stop Bit Select
Two
One
One
ASCII Format
7-Bit
8-Bit
8-Bit
Beep On <BEL>
Disabled
Disabled
Disabled
RTS Line State
Low
High
Low
RS-232C UPC-A Code ID
“A”
“A”
“A”
RS-232C UPC-E Code ID
“A”
“E0”
“C0”
RS-232C EAN-8 Code ID
“A”
“FF”
“B”
RS-232C EAN-13 Code ID
“A”
“F”
“A”
RS-232C Code 39 Code ID
“B”
“C”
“M”
RS-232C Codabar Code ID
“C”
“N”
“N”
RS-232C Code 128 Code ID
“D”
None
“K”
RS-232C I 2 of 5 Code ID
“F”
“I”
“I”
RS-232C MSI/Plessey Code ID
“J”
None
“O”
40
Page 43
Q u i c k
R e f e r e n c e
Test Symbols
Code 128
EAN-8
13 Mil UPC
Code 39
41
Page 44
L S
3 0 7 0
S c a n n e r
Test Symbols: Long Range Scanners
5012345248 Code 128
001234 Interleaved 2 Of 5
01234 Code 39
42
Page 45
Q u i c k
R e f e r e n c e
Service Information Before you use the unit, it must be configured to operate in your facility’s network and run your applications. If you have a problem running your unit or using your equipment, contact your facility’s Technical or Systems Support. If there is a problem with the equipment, they will contact the Symbol Support Center: United States
1-800-653-5350
Canada
905-629-7226
United Kingdom
0800 328 2424
Asia/Pacific
337-6588
Australia
1-800-672-906
Austria
1-505-5794
Denmark
7020-1718
Finland
9 5407 580
France
01-40-96-52-21
Germany
6074-49020
Italy
2-484441
Mexico
5-520-1835
Netherlands
315-271700
Norway
66810600
South Africa
11-4405668
Spain
9-1-320-39-09
Sweden
84452900
Latin America Sales Support
1-800-347-0178 Inside US +1-561-483-1275 Outside US
Europe/Mid-East Distributor Operations Contact local distributor or call +44 118 945 7360
Warranty Symbol Technologies, Inc. (“Symbol”) manufactures its hardware products in accordance with industry-standard practices. Symbol warrants that for a period of twelve (12) months from date of shipment, products will be free from defects in materials and workmanship. This warranty is provided to the original owner only and is not transferable to any third party. It shall not apply to any product (i) which has been repaired or altered unless done or approved by Symbol, (ii) which has not been maintained in accordance with any operating or handling instructions supplied by Symbol, (iii) which has been subjected to unusual physical or electrical stress, misuse, abuse, power shortage, negligence or accident or (iv) which has been used other than in accordance with the product operating and handling instructions. Preventive maintenance is the responsibility of customer and is not covered under this warranty. Wear items and accessories having a Symbol serial number, will carry a 90-day limited warranty. Non-serialized items will carry a 30-day limited warranty.