The text of a manual · part 1 of 6
LS 3070 Scanner Quick Reference, pages 1 to 9
Pages 1 to 9 of 52
The original document is the PDF (385 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-3070
Page 1
OD Dll
Page 2
L S
3 0 7 0
S c a n n e r
1997-1999 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products. Symbol is a registered trademark of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No.4,360,798; 4,369,361; 4,387,297; 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025;D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581. Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan). European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/ 03938; Italy 1,138,713. rev. 7/99
Page 3
Q u i c k
R e f e r e n c e
Scanner Varieties The LS 3070 scanners include a wide variety of scanning types, optimized for particular applications. The varieties are the following: •
•
•
•
•
Standard - for most Class II scanning applications, in which symbol density (5 to 55 mil) and range (0 - 35 in.) fall within relatively normal ranges. Long Range (LR) - for Class II applications with short range reading on medium density symbols and long range reading on low density symbols. Advanced Long Range (ALR) - for long range reading on medium and low-density symbols, optimized by the increased power of the Class IIIA laser. Extra Long Range (XLR) - for scanning ranges of up to 180 inches (457 cm) on 55 mil symbols, also using a Class IIIA laser. High Visibility (HV) - for scanning ranges up to 33 inches (86 cm) on 55 mil symbols, and ambient sunlight up to 10,000 ft. candles, using a Class IIIA laser.
1
Page 4
L S
3 0 7 0
S c a n n e r
Setup 1. Identify System Components
Power Supply
LS 3070 Scanner RL 470 Base/Interface/ Charger Unit
2. Connect Cable to the Base/Charger Unit This procedure depends on which host terminal is used. For complete details per terminal type, refer to the RL 470 Base Station Interface portion of the LS 3070 Product Reference Guide.
3. Attach Power Supply Connect the power supply to the power input port on the rear panel of the LS 3070 base/interface/charger. Power Supply Connection Port Host
Connect the power supply to a receptacle supplying AC power of the proper voltage level.
2
Page 5
Q u i c k
R e f e r e n c e
4. Insert Scanner Into Base/Charger and Charge the Battery Before its first use, the LS 3070 battery must be charged. After the power supply has been connected, insert the scanner into the base/charger cradle as follows. a. Place the nose of the scanner into the large rectangular receptacle of the base/charger. b. Then place the handle of the scanner into the opening of the smaller latched receptacle. c. Press down firmly until the bottom of the handle seats snugly into the receptacle and engages the latch. Caution:
Use of excessive force in placing the scanner into the base can damage the charging contacts on the scanner or base. Such damage can interfere with or prevent charging of the scanner’s batteries by the base.
Check the charge-status indicator LED; it stays steadily on while the battery is charging and blinks rapidly when the battery is fully charged. Full charge takes less than two hours. To remove the scanner from the base/charger, grasp the handle of the scanner and lift the bottom of the handle out of the latched receptacle, thereby freeing the scanner from the base. Caution:
Trying to remove the scanner nose first, instead of handle first, can break the latch in the base receptacle.
3
Page 6
L S
3 0 7 0
S c a n n e r
5. Set Address of the Base/Charger The base/charger must be assigned an address, with a value between 01 and 7E. Caution:
Each base station must have a unique address.
The unique address of the base determines the initial frequency on which the base and the scanner communicate. To minimize possible interference between systems, bases which are close to each other should be assigned sequential addresses. Set the address through setting the two rotary dials, located by opening a panel on the base/charger’s underside. Turn the base/ charger upside down, open the panel, and notice two rotary dials.
4
Page 7
Q u i c k
R e f e r e n c e
Insert Screwdriver in Slot 0
0
High Order 10 Position
Low Order 16 Position
Rotary Switches
The first is a 10-position (0 to 9, high order address digit) and the second a 16-position (0 to F, low order address digit). Digits are printed sequentially around each circle. Note that positions 8 and 9 are illegal on the 10-position switch. Set the desired address with a small screwdriver; possible addresses are listed on the next page. Note that too large a screwdriver can damage the switches. When the address is set, close the panel, turn the base/charger rightside up again. Possible Base/Charger Addresses 01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
5
Page 8
L S
3 0 7 0
S c a n n e r
6. Pair Scanner with Base/Charger The wireless “connection” between the scanner and base/charger is the low power radio transmission through RF transceivers in the both the scanner and base/charger. The actual communication consists of bidirectional message packets. However, the scanner and base/charger must be paired for this communication to work between the two devices. To pair the scanner with the base/charger: •
Scan the PAIRING bar code on the next page or on the RL 470 base.
PAIRING
Then insert the scanner into the base/charger’s cradle. You have 15 seconds to do this, or there will be error beeps (4 beeps = unsuccessful pairing or base not powered). Note that you cannot scan data until this linking is complete.
•
At that time, through the scanner’s contact shoe, there is an exchange of information (addressing, RF channels, etc.) between the scanner and the base/charger’s cradle. This occurs in less than a second.
•
6
Page 9
Q u i c k
•
R e f e r e n c e
After that exchange, the scanner and base/charger are paired. Successful pairing is indicated by as warble beep; failure, or unsuccessful link, is indicated by a Lo Lo Lo Lo beep.
7. Set Host Type Each Interface Cable Assembly defaults to a given host. Below is a list of the assemblies and their corresponding default hosts. If you wish to change the type of host, find and scan the proper bar code on the following pages. Cable Assy.
Default
IK-0100, -0101 IK-1005, -1006 IK-0200 IK-0300 IK-0400 IK-0401 IK-0402, -0403 IK-0406, -0409 IK-0413 IK-0500 IK-0600 IK-0700 IK-0800, 0803 IK-0900 IK-0901 IK-0902 IK-1001, -1002 IK-1003, -1004 IK-1100 IK-1200, -1201 IK-1300 IK-1301 IK-1400 IK-1500, -1501
IBM 4683/93 Port 5B; 4683/84 Port 17 ICL 9505, 9507, 9518; 9520 OCIA IBM 3683, 3684 Keybd Wedge IBM 3653 Kybd Wedge IBM PC/AT, Telex Memorex Kybd Wedges IBM PS/2 - 30, 50, 55SX, 60, 70, 80 NCR 7052 Wedge; Fujitsu 9000 Wedge IBM 3161/319X; IBM 3151, 347X Wedges Wyse 50 Wedge NCR 2152 Tel Kybd Wedge NCR 2151 Tel Kybd Wedge NCR 280 Kybd Wedge Standard RS-232C Fujitsu 9000 OCR Fujitsu 7770, 7880, 7990, 8770 OCR IBM 3653, 3683/3684 OCR NCR 2152, 2257, 2950; 215X, 7050 OCIA Nixdorf 8812 OCIA; NCR 2126-1120 OCIA IBM 4683/93 Port 9B IBM 3178; IBM 3278 Wedges Wyse 60, 85, 150, 160, 185 Wedges HP 7000/XX, 239X Wedges DEC VT 2XX/3XX/4XX Wedges Dual RS-232C
7