The text of a manual · part 11 of 14
LS 3064MX Product Reference Guide, pages 101 to 110
Pages 101 to 110 of 140
The original document is the PDF (318 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-3064
Page 101
LS 3064MX PROGRAMMERS GUIDE
Parameter Menus
Set Serial Number (Continued)
G N U H fe) V I P W J Q X K R Y L S Z M T
P70
Page 102
LS 3064MX PROGRAMMER’S GUIDE
Set Serial Number (Continued)
0
5
1
6
2
7
3
8
4
9
END SERIAL NUMBER
P71
Page 103
LS 3064MX PROGRAMMER’S GUIDE
Parameter Menus Abort Procedure To select an abort procedure on communications failure: 1. Scan the bar code representing the abort procedure required. 2. Scan ENABLE or DISABLE . 3. Scan ENTER .
ABORT PROCEDURE
P72
Page 104
LS 3064MX PROGRAMMER’S GUIDE
Abort Procedure
ENABLE (ABORT DOWNLOAD)
DISABLE (IGNORE COMMS ERROR; SKIP TO NEXT SYMBOL)
BACKSPACE - deletes the last bar code scanned. CANCEL - deletes entire change and returns you to the decode mode. ENTER - stores and enters the new change.
BACKSPACE
ENTER
CANCEL
P73
Page 105
LS 3064MX PROGRAMMER’S GUIDE
Parameter Menus Quantity Field When this parameter is enabled, use the bar codes on page OP6 to enter a quantity. To enable or disable this parameter: 1. Scan the QUANTITY FIELD bar code. 2. Scan ENABLE or DISABLE . 3. Scan ENTER . Note: This parameter can only be set when the buffer is empty.
QUANTITY FIELD
P74
Page 106
LS 3064MX PROGRAMMER’S GUIDE
Quantity Field
ENABLE
DISABLE
BACKSPACE - deletes the last bar code scanned. CANCEL - deletes entire change and returns you to the decode mode. ENTER - stores and enters the new change.
ENTER
BACKSPACE
CANCEL
P75
Page 107
LS 3064MX PROGRAMMER’S GUIDE
Parameter Menus Transmit Quantity To enable or disable this parameter: 1. Scan the TRANSMIT QUANTITY bar code. 2. Scan ENABLE or DISABLE . 3. Scan ENTER .
TRANSMIT QUANTITY
P76
Page 108
LS 3064MX PROGRAMMER’S GUIDE
Transmit Quantity
OPTION 2 (Transmit bar code data and a quantity, n)
OPTION 1 (Transmit bar code data n times)
BACKSPACE - deletes the last bar code scanned. CANCEL - deletes entire change and returns you to the decode mode. ENTER - stores and enters the new change.
BACKSPACE
ENTER
CANCEL
P77
Page 109
LS 3064MX PROGRAMMER’S GUIDE
Parameter Menus Terminating String To establish a terminating string, scan the symbol below and then scan the bar code to be used as the terminating string.
SELECT TERMINATING STRING
Note: The above parameter is valid only when downloading via scanner port.
P78
Page 110
LS 3064MX PROGRAMMER’S GUIDE
Interdecode/Terminating String Delay To set an Interdecode or Terminating String Delay: 1. Scan a Delay bar code. 2. Scan two bar codes from the following page in the range 00-99. 3. Scan ENTER . Note: The Delay parameters are valid only when downloading via scanner port.
INTERDECODE DELAY
TERMINATING STRING DELAY
P79