LS1900T/LS1908X Product Reference Guide: Chapter 3 Maintenance and Technical Specifications

Pages 39 to 46 of 356, from LS1900T/LS1908X Product Reference Guide

The original document is the PDF (3.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-1900 and Symbol LS-1908

Page 39

Chapter 3 Maintenance and Technical Specifications Introduction This chapter covers suggested scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts).

Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. •

Do not allow any abrasive material to touch the window

•

Remove any dirt particles with a damp cloth

•

Wipe the window using a tissue moistened with ammonia/water

•

Do not spray water or other cleaning liquids directly into the window

•

Do not remove the rubber nose of the scanner.

3-1

Page 40

LS1900T/LS1908X Product Reference Guide

Troubleshooting Table 3-1. Troubleshooting Problem

Possible Causes

Nothing happens when No power to the scanner. you follow the operating instructions, or the scanner displays erratic behavior (laser does not come on, scanner emits frequent beeps). Interface/power cables are loose. Laser comes on, but Scanner is not programmed symbol does not decode. for the correct bar code type.

Symbol is decoded, but not transmitted to the host.

3-2

Possible Solutions Check the system power. Ensure the power supply is connected if your configuration requires a power supply.

Check for loose cable connections. Be sure the scanner is programmed to read the type of bar code you are scanning.

Bar code symbol is unreadable.

Check the symbol to make sure it is not defaced. Try scanning test symbols of the same bar code type.

Distance between scanner and bar code is incorrect.

Move the scanner closer to or further from the bar code.

Scanner is not programmed for the correct host type.

Scan the appropriate host type bar code.

Page 41

Maintenance and Technical Specifications

Table 3-1. Troubleshooting (Continued) Problem Scanned data is incorrectly displayed on the host.

Possible Causes

Possible Solutions

Scanner is not programmed to Be sure proper host is selected. (See the work with the host. Check host chapter for your scanner.) scanner host type parameters or editing options. For RS-232, ensure the scanner’s communication parameters match the host’s settings. For a USB HID keyboard or a keyboard wedge configuration, ensure the system is programmed for the correct keyboard type and language, and the CAPS LOCK key is in the correct state. Be sure editing options (e.g., ADF, UPCE to UPC-A Conversion) are properly programmed.

Note: If after performing these checks the symbol still does not scan, contact your distributor or call the local Symbol Support Center. See page xiv for the telephone numbers.

3-3

Page 42

LS1900T/LS1908X Product Reference Guide

Technical Specifications Table 3-2. Technical Specifications Item

Description

Power Requirements

LS 1900T: 4.5 – 5.5 VDC @ 100 mA nominal LS 1908C/T: 4.5 – 5.5 VDC @ 145 mA nominal

Stand-By Current

1 mA (max)

Power Source

Decoded: Depending on host: • Host powered • External power supply • Battery box: Converts 9 Volt battery to 5 Volt battery yielding over 10,000 scans Undecoded: Power supplied by interface controller

Decode Capability

Decoded: UPC/EAN, UPC/EAN with supplementals, UCC/EAN 128, Code 39, Code 39 Full ASCII, Code 39 Trioptic, Codabar (NW7), Interleaved 2 of 5, Discrete 2 of 5, Code 128, Code 93, MSI, Code 11, UCC/EAN RSS, Code 32, Coupon Code, and Bookland EAN Undecoded: Determined by interface controller

3-4

Beeper Operation

User-selectable: Enable, Disable

Beeper Volume

User-selectable: three levels

Beeper Tone

User-selectable: three tones

Decode Depth of Field

Refer to LS190XC Decode Zone on page 2-7and LS190XT Decode Zone on page 2-8.

Scan Repetition Rate

Approximately 44 scans/sec. (bidirectional)

Skew Tolerance

± 60° min. (from normal)

Pitch Tolerance

± 65° (from normal)

Page 43

Maintenance and Technical Specifications

Table 3-2. Technical Specifications (Continued) Item

Description

Roll Tolerance

± 10° (from normal) dependent on bar code height

Print Contrast Minimum

25% minimum reflectance differential, measured at 650 nm.

Ambient Light Immunity Indoor: Outdoor:

450 Ft Candles (4,842 Lux) 8,000 Ft Candles (86,112 Lux)

Durability

5 ft (1.5 m) drops to concrete

Operating Temperature

32° to 104° F (0° to 40° C)

Storage Temperature

-40° to 140° F (-40° to 60° C)

Humidity

5% to 95% (non-condensing)

Weight (without cable)

LS190XC/T: 4.2 oz. (120 g)

Dimensions: Height Width Depth

5.3 in. (13.5 cm) 2.5 in. (6.4 cm) 2.2 in. (5.6 cm)

Laser

650nm laser diode

Laser Classifications

CDRH Class 2 (triggered models) IEC 825-1 Class 1 (triggerless models)

ESD

15 kV air discharge 8 kV contact discharge

Minimum Element Width

5 mil (0.127 mm)

Interfaces Supported

Decoded: RS-232, Keyboard Wedge, Wand Emulation, IBM 468X/469X, USB, Synapse Undecoded: Undecoded (Decoding is based on interface controller)

3-5

Page 44

LS1900T/LS1908X Product Reference Guide

Scanner Signal Descriptions

Bottom of scanner

Cable interface port

PIN 10

PIN 1

Interface cable modular connector

Figure 3-1. Scanner Cable Pinouts

3-6

Page 45

Maintenance and Technical Specifications

The signal descriptions in Table 3-3 apply to the connector on the scanner and are for reference only.

Table 3-3. Scanner Signal Pin-outs LS1900T Pin

LS1908X IBM

Synapse

RS-232

Keyboard Wedge

Wand

USB

1

Reserved Reserved

SynClock

Reserved

Reserved

Reserved Jump to Pin 6

2

Power

Power

Power

Power

Power

Power

Power

3

Ground

Ground

Ground

Ground

Ground

Ground

Ground

4

Enable

IBM_A(+)

Reserved

TxD

KeyClock

DBP

Reserved

5

SOS

Reserved

Reserved

RxD

TermData

CTS

D+

6

Trigger*

IBM_B(-)

SynData

RTS

KeyData

RTS

Jump to Pin 1

7

Decode

Reserved

Reserved

CTS

TermClock

Reserved D -

8

DBP

Reserved

Reserved

Reserved

Reserved

Reserved Reserved

9

Reserved Reserved

Reserved

Reserved

Reserved

Reserved Reserved

10

Reserved Reserved

Reserved

Reserved

Reserved

Reserved Reserved

3-7

Page 46 read from a scan by OCR; it may hold reading errors

NO yA |_! LS1900T/LS1908X Product Reference Guide

3-8