The text of a manual · part 37 of 42
LS1900T/LS1908X Product Reference Guide: Appendix B Programming Reference
Pages 327 to 330 of 356, from LS1900T/LS1908X Product Reference Guide
The original document is the PDF (3.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-1900 and Symbol LS-1908
Page 327
Appendix B Programming Reference Symbol Code Identifiers Table B-1. Code Characters Code Character
Code Type
A
UPC-A, UPC-E, UPC-E1, EAN-8, EAN-13
B
Code 39
C
Codabar
D
Code 128
E
Code 93
F
Interleaved 2 of 5
G
Discrete 2 of 5, or Discrete 2 of 5 IATA
J
MSI
K
UCC/EAN-128
L
Bookland EAN
M
Trioptic Code 39
N
Coupon Code
B-1
Page 328
LS1900T/LS1908X Product Reference Guide
AIM Code Identifiers Each AIM Code Identifier contains the three-character string ]cm where: ] = c = m =
Flag Character (ASCII 93) Code Character (see Table B-2) Modifier Character (see Table B-3)
Table B-2. Code Characters
B-2
Code Character
Code Type
A
Code 39
C
Code 128
E
UPC/EAN
F
Codabar
G
Code 93
H
Code 11
I
Interleaved 2 of 5
M
MSI
S
D2 of 5, IATA 2 of 5
X
Code 39 Trioptic
X
Bookland EAN
X
Coupon Code
Page 329
Programming Reference
The modifier character is the sum of the applicable option values based on Table B-3. Table B-3. Modifier Characters Code Type Code 39
Option Value
Option
0
No check character or Full ASCII processing.
1
Reader has checked one check character.
3
Reader has checked and stripped check character.
4
Reader has performed Full ASCII character conversion.
5
Reader has performed Full ASCII character conversion and checked one check character.
7
Reader has performed Full ASCII character conversion and checked and stripped check character.
Example:A Full ASCII bar code with check character W, A+I+MI+DW, is transmitted as ]A7AIMID where 7 = (3+4). Trioptic Code 39
0
No option specified at this time. Always transmit 0.
Example:A Trioptic bar code 412356 is transmitted as ]X0412356 Code 128
0
Standard data packet, no Function code 1 in first symbol position.
1
Function code 1 in first symbol character position.
2
Function code 1 in second symbol character position.
Example:A Code (EAN) 128 bar code with Function 1 character in the first position, )1& AIMID is transmitted as @C1AIMID I 2 of 5
0
No check digit processing.
1
Reader has validated check digit.
3
Reader has validated and stripped check digit.
Example:An I 2 of 5 bar code without check digit, 4123, is transmitted as ]I04123 Codabar
0
No check digit processing.
1
Reader has checked check digit.
3
Reader has stripped check digit before transmission.
Example:A Codabar bar code without check digit, 4123, is transmitted as ]F04123
B-3
Page 330
LS1900T/LS1908X Product Reference Guide
Table B-3. Modifier Characters (Continued) Code Type
Option Value
Option
Code 93 0
No options specified at this time. Always transmit 0.
Example:A Code 93 bar code 012345678905 is transmitted as ]G0012345678905 MSI
0
Check digits are sent.
1
No check digit is sent.
Example:An MSI bar code 4123, with a single check digit checked, is transmitted as ]M14123 D 2 of 5
0
No options specified at this time. Always transmit 0.
Example:A D 2 of 5 bar code 4123, is transmitted as ]S04123 UPC/EAN
0
Standard packet in full EAN country code format, which is 13 digits for UPC-A and UPC-E (not including supplemental data).
1
Two-digit supplement data only.
2
Five-digit supplement data only.
4
EAN-8 data packet.
Example:A UPC-A bar code 012345678905 is transmitted as ]E00012345678905 Bookland EAN
0
No options specified at this time. Always transmit 0.
Example:A Bookland EAN bar code 123456789X is transmitted as ]X0123456789X
B-4