Page 203
Symbologies
Set Lengths for Discrete 2 of 5 (continued) Length Within Range - This option allows you to decode an D 2 of 5 symbol with a specific length range. The length range is selected from numeric bar codes beginning on page D-1 in Appendix D. For example, to decode D 2 of 5 symbols containing between 4 and 12 characters, first scan D 2 of 5 - Length Within Range. Then scan 0, 4, 1, and 2. If you make an error or wish to change your selection, scan Cancel on page D-5.
D 2 of 5 - Length Within Range
Any Length - Scanning this option allows you to decode D 2 of 5 symbols containing any number of characters within the scanner capability. Note: Due to the construction of the D 2 of 5 symbology, it is possible for a scan line covering only a portion of the code to be interpreted as a complete scan, yielding less data than is actually encoded in the bar code. To prevent this from happening, it is recommended that specific lengths (D 2 of 5 - One Discrete Length - Two Discrete Lengths) be selected for D 2 of 5 applications.
D 2 of 5 - Any Length
11-59
Page 204
LS1900T/LS1908X Product Reference Guide
Codabar (NW - 7) Enable/Disable Codabar To enable or disable Codabar, scan the appropriate bar code below.
Enable Codabar
*Disable Codabar
11-60
Page 205
Symbologies
Set Lengths for Codabar The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Lengths for Codabar may be set for any length, one or two discrete lengths, or lengths within a specific range. Note: When setting lengths for different bar code types by scanning single digit numbers, single digit numbers must always be preceded by a leading zero. One Discrete Length - This option allows you to decode only those Codabar symbols containing a selected length. Lengths are selected from the numeric bar codes beginning on page D-1 in Appendix D. For example, to decode only Codabar symbols with 14 characters, scan Codabar - One Discrete Length, then scan 1 followed by 4. If you make an error or wish to change your selection, scan Cancel on page D-5.
Codabar - One Discrete Length
Two Discrete Lengths - This option allows you to decode only those Codabar symbols containing either of two selected lengths. Lengths are selected from the numeric bar codes beginning on page D-1 in Appendix D. For example, to decode only those Codabar symbols containing either 2 or 14 characters, select Codabar - Two Discrete Lengths, then scan 0, 2, 1, and then 4. If you make an error or wish to change your selection, scan Cancel on page D-5.
Codabar - Two Discrete Lengths
11-61
Page 206
LS1900T/LS1908X Product Reference Guide
Set Lengths for Codabar (continued) Length Within Range - This option allows you to decode a Codabar symbol with a specific length range. The length range is selected from numeric bar codes beginning on page D-1 in Appendix D. For example, to decode Codabar symbols containing between 4 and 12 characters, first scan Codabar - Length Within Range. Then scan 0, 4, 1, and 2. If you make an error or wish to change your selection, scan Cancel on page D-5.
Codabar - Length Within Range
Any Length - Scanning this option allows you to decode Codabar symbols containing any number of characters within the scanner capability.
Codabar - Any Length
11-62
Page 207
Symbologies
CLSI Editing When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Enable this feature if your host system requires this data format. Note: Symbol length does not include start and stop characters.
Enable CLSI Editing
*Disable CLSI Editing
11-63
Page 208
LS1900T/LS1908X Product Reference Guide
NOTIS Editing When enabled, this parameter strips the start and stop characters from a decoded Codabar symbol. Enable this feature if your host system requires this data format.
Enable NOTIS Editing
*Disable NOTIS Editing
11-64
Page 209
Symbologies
MSI Enable/Disable MSI To enable or disable MSI, scan the appropriate bar code below.
Enable MSI
*Disable MSI
11-65
Page 210
LS1900T/LS1908X Product Reference Guide
Set Lengths for MSI The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Lengths for MSI may be set for any length, one or two discrete lengths, or lengths within a specific range. Note: When setting lengths for different bar code types by scanning single digit numbers, single digit numbers must always be preceded by a leading zero. One Discrete Length - This option allows you to decode only those MSI symbols containing a selected length. Lengths are selected from the numeric bar codes beginning on page D-1 in Appendix D. For example, to decode only MSI symbols with 14 characters, scan MSI - One Discrete Length, then scan 1 followed by 4. If you make an error or wish to change your selection, scan Cancel on page D-5.
MSI - One Discrete Length
Two Discrete Lengths - This option allows you to decode only those MSI symbols containing either of two selected lengths. Lengths are selected from the numeric bar codes beginning on page D-1 in Appendix D. For example, to decode only those MSI symbols containing either 2 or 14 characters, select MSI - Two Discrete Lengths, then scan 0, 2, 1, and then 4. If you make an error or wish to change your selection, scan Cancel on page D-5.
MSI - Two Discrete Lengths
11-66
Page 211
Symbologies
Set Lengths for MSI (continued) Length Within Range - This option allows you to decode an MSI symbol with a specific length range. The length range is selected from numeric bar codes beginning on page D-1 in Appendix D. For example, to decode MSI symbols containing between 4 and 12 characters, first scan MSI - Length Within Range. Then scan 0, 4, 1, and 2. If you make an error or wish to change your selection, scan Cancel on page D-5.
MSI - Length Within Range
Any Length - Scanning this option allows you to decode MSI symbols containing any number of characters within the scanner capability. Note: Due to the construction of the MSI symbology, it is possible for a scan line covering only a portion of the code to be interpreted as a complete scan, yielding less data than is actually encoded in the bar code. To prevent this from happening, it is recommended that specific lengths (MSI - One Discrete Length - Two Discrete Lengths) be selected for MSI applications.
MSI - Any Length
11-67
Page 212
LS1900T/LS1908X Product Reference Guide
MSI Check Digits With MSI symbols, one check digit is mandatory and always verified by the reader. The second check digit is optional. If your MSI codes include two check digits, enable the verification of the second check digit by scanning the barcode below. Refer to MSI Check Digit Algorithm on page 11-70 for the selection of second digit algorithms.
*One MSI Check Digit
Two MSI Check Digits
11-68