Page 81

Chapter 6 RS-232 Interface

Introduction This chapter covers RS-232 host information for setting up your scanner. The RS-232 interface is used to attach the scanner to point-of-sale devices, host computers, or other devices with an available RS-232 port (e.g., com port). If your particular host is not listed in Table 6-2, you need to set the communication parameters to match your host device. To set communication parameters for hosts not listed, refer to the documentation for the host device. Throughout the programming bar code menus, default values are indicated with asterisks (*).

* Indicates Default

*Baud Rate 9600

Feature/Option

6-1

Page 82

LS1900T/LS1908X Product Reference Guide

Connecting an RS-232 Interface This connection is made directly from the scanner to the host computer. Serial Port Connector to Host Power supply cable Interface cable

Interface cable

Power supply

Figure 6-1. RS-232 Direct Connection 1. Connect the RS-232 interface cable to the bottom of the scanner, as described in Installing the Interface Cable on page 1-3. 2. Connect the other end of the interface cable to the serial port on the host. 3. Connect the power supply. 4. Scan appropriate bar codes in this chapter to match your host settings.

RS-232 Default Parameters Table 6-1 lists the defaults for RS-232 host parameters. If you wish to change any option, scan the appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 6-4.

6-2

Page 83

RS-232 Interface

Note: See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters. Table 6-1. RS-232 Host Default Table Parameter

Default

Page Number

RS-232 Host Parameters RS-232 Host Type

Standard RS-2321

6-6

Baud Rate

9600

6-9

Parity

None

6-11

Check Receive Errors

Enable

6-12

Hardware Handshaking

None

6-14

Software Handshaking

None

6-15

Host Serial Response Time-out

2 Sec

6-17

RTS Line State

Low RTS

6-18

Stop Bit Select

1 Stop Bit

6-19

ASCII Format

8-Bit

6-19

Beep on <BEL>

Disable

6-20

Intercharacter Delay

0 msec

6-21

1User selection is required to configure this interface and this is the most common selection.

6-3

Page 84

LS1900T/LS1908X Product Reference Guide

RS-232 Host Parameters Various RS-232 hosts are set up with their own parameter default settings (Table 6-2). Selecting the ICL, Fujitsu, Wincor-Nixdorf Mode A, or Wincor-Nixdorf Mode B/OPOS terminal sets the defaults listed below. These defaults take precedence over standard defaults and remain selected if the Set Defaults bar code is scanned. Table 6-2. Terminal Specific RS-232

Parameter

Standard (Default)

ICL

WincorNixdorf Mode A

Fujitsu

WincorNixdorf Mode B/ OPOS

Transmit Code ID

No

Yes

Yes

Yes

Yes

Data Transmission Format

Data as is

Data/Suffix

Data/Suffix

Data/Suffix

Data/Suffix

Suffix

CR/LF (7013) CR (1013)

CR (1013)

CR (1013)

CR (1013)

Baud Rate

9600

9600

9600

9600

9600

Parity

None

Even

None

Odd

Odd

Hardware Handshaking

None

RTS/CTS Option 3

None

RTS/CTS Option 3

RTS/CTS Option 3

Software Handshaking

None

None

None

None

None

Serial Response Timeout

2 Sec.

9.9 Sec.

2 Sec.

9.9 Sec.

9.9 Sec.

Stop Bit Select

One

One

One

One

One

ASCII Format

8-Bit

8-Bit

8-Bit

8-Bit

8-Bit

Beep On <BEL>

Disable

Disable

Disable

Disable

Disable

RTS Line State

Low

High

Low

Low

Low = No data to send

6-4

Page 85

RS-232 Interface

RS-232 Host Parameters (continued) Selecting the ICL, Fujitsu, Wincor-Nixdorf Mode A, or Wincor-Nixdorf Mode B/OPOS terminal enables the transmission of code ID characters listed in Table 6-3 below. These code ID characters are not programmable and are separate from the Transmit Code ID feature. The Transmit Code ID feature should not be enabled for these terminals.

Table 6-3. Terminal Specific Code ID Characters ICL

Wincor-Nixdorf Mode A

Fujitsu

Wincor-Nixdorf Mode B/OPOS

UPC-A

A

A

A0

A0

UPC-E

E

E

C0

C0

EAN-8

FF

FF

B

B

EAN-13

F

F

A

A

Code 39

C <len>

None

M

M

Codabar

N <len>

None

N

N

Code 128

L <len>

None

K

K

I 2 of 5

I <len>

None

I

I

Code 93

None

None

L

L

D 2 of 5

H <len>

None

H

H

UCC/EAN 128

L <len>

None

P

P

MSI

None

None

O

O

Bookland EAN

F

F

A

A

Trioptic

None

None

None

None

Code 11

None

None

None

None

RSS 14

None

None

None

E

RSS Limited

None

None

None

E

RSS Expanded

None

None

None

E

6-5

Page 86

LS1900T/LS1908X Product Reference Guide

RS-232 Host Types Select an RS-232 host by scanning one of the bar codes below.

Standard RS-2321

ICL RS-232

Wincor-Nixdorf RS-232 Mode A

Wincor-Nixdorf RS-232 Mode B

Note: 1User selection is required to configure this interface and this is the most common selection.

6-6

Page 87

RS-232 Interface

RS-232 Host Types (continued)

OPOS

Fujitsu RS-232

6-7

Page 88

LS1900T/LS1908X Product Reference Guide

Baud Rate Baud rate is the number of bits of data transmitted per second. The scanner’s baud rate setting should match the baud rate setting of the host device. If not, data may not reach the host device or may reach it in distorted form.

Baud Rate 600

Baud Rate 1200

Baud Rate 2400

Baud Rate 4800

6-8

Page 89

RS-232 Interface

Baud Rate (continued)

*Baud Rate 9600

Baud Rate 19,200

Baud Rate 38,400

6-9

Page 90

LS1900T/LS1908X Product Reference Guide

Parity A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.

Odd

Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.

Even

Select Mark parity and the parity bit is always 1.

Mark

6-10