The text of a manual · part 1 of 6
LS1900 Series Quick Reference, pages 1 to 10
Pages 1 to 10 of 56
The original document is the PDF (1.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-1900, Symbol LS-1902 and Symbol LS-1908
Page 1
L S S e
1 r
9 i
0 e
0 s
Page 2
L S 1 9 0 0 S e r i e s
© 2002 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products. Symbol and the Symbol logo are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No. 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,760,248; 4,806,742; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,848,064; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025; 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,947; 6,029,894: 6,031,830; 6,036,098; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297; 6,082,621; 6,084,528; 6,088,482; 6,092,725; 6,101,483; 6,102,293; 6,104,620; 6,114,712; 6,115,678; 6,119,944; 6,123,265; 6,131,814; 6,138,180; 6,142,379; 6,172,478; 6,176,428; 6,178,426; 6,186,400; 6,188,681; 6,209,788; 6,209,789; 6,216,951; 6,220,514; 6,243,447; 6,244,513; 6,247,647; 6,308,061 6,250,551; 6,295,031; 6,308,061; 6,308,892; 6,321,990; 6,328,213; 6,330,244; 6,336,587; 6,340,114; 6,340,115; 6,340,119; 6,348,773; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581; D414,171; D414,172; D418,500; D419,548; D423,468; D424,035; D430,158; D430,159; D431,562; D436,104. Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan); European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713 rev. 03/02
Page 3
Q u i c k R e f e r e n c e
Introduction The LS1900 Series scanner combines excellent scanning performance and advanced ergonomics to provide the best value in a lightweight laser scanner. Whether used as a hand-held scanner or in hands-free mode in a stand, the LS1900 Series ensures comfort and ease of use for extended periods of time. Note: Unless otherwise noted, the term LS190xx refers to all versions of the scanner.
Parts of the LS1900 Series Scanner LED Beeper
Exit Window
Trigger (Model LS190xT only)
Installing the Interface Cable 1.
Plug the interface cable modular connector into the cable interface port on the bottom of the LS1900 Series handle.
Cable interface port Interface cable modular connector
2. 3.
Connect the other end of the interface cable to the host. Connect the power supply to the cable (if necessary).
1
Page 4
L S 1 9 0 0 S e r i e s
4.
Scan the appropriate bar code(s) beginning on page 42 to communicate with the host.
Removing the Interface Cable Unplug the installed cable’s modular connector by depressing the connector clip with the tip of a screwdriver.
Aiming Note:
The scanner performs best when it is not exactly perpendicular to the bar code.
6
6
4
Scanning In Hand-Held Mode 1. 2.
3.
4.
Ensure all connections are secure. Aim the scanner at the bar code. (If your scanner has a trigger, aim the scanner and press the trigger.) Ensure the scan line crosses every bar and space of the symbol. RIGHT
WRONG
012345
012345
Upon successful decode, the scanner beeps and the LED turns green.
Scanning in Hands-Free Mode (LS1902x and LS1908x only) In the stand, the scanner is in constant-on mode. When you remove the scanner from the stand it operates in its normal hand-held mode (e.g., constant-on mode or trigger mode, depending on the model).
2
Page 5
Q u i c k R e f e r e n c e
1. 2.
3.
Insert scanner in stand. Present bar code and ensure the scan line crosses every bar and space of the symbol. Upon successful decode, the scanner beeps and the LED turns green.
Troubleshooting Problem
Possible Cause
Possible Solutions
Nothing happens when you follow the operating instructions.
No power to the scanner.
Check the system power. Ensure the power supply is connected if your configuration requires a power supply.
Interface/ power cables are loose.
Check for loose cable connections.
Scanner is not programmed for the correct bar code type.
Be sure the scanner is programmed to read the type of bar code you are scanning.
Bar code symbol is unreadable.
Check the symbol to make sure it is not defaced. Try scanning test symbols of the same bar code type.
Laser comes on, but symbol does not decode.
3
Page 6
L S 1 9 0 0 S e r i e s
Problem
Possible Cause
Possible Solutions
(Cont’d)
Distance between scanner and bar code is incorrect.
Move the scanner closer to or further from the bar code.
Symbol is decoded, but not transmitted to the host.
Scanner is not programmed for the correct host type.
Scan the appropriate host type bar code.
Scanned data is incorrectly displayed on the host.
Scanner is not programmed to work with the host. Check LS1900 Series host type parameters or editing options.
Be sure proper host is selected. For RS-232, ensure the scanner’s communication parameters match the host’s settings. For a keyboard wedge configuration, ensure the system is programmed for the correct keyboard type, and the CAPS LOCK key is off. Be sure editing options (e.g., UPC-E to UPC-A Conversion) are properly programmed.
4
Page 7
G u i d e u t i l i s a t e u r
Présentation Le lecteur de la série LS1900 allie des performances de lecture excellentes à une ergonomie sophistiquée, ce qui fait de lui le meilleur lecteur laser léger de sa catégorie. Qu’il soit utilisé comme lecteur portable ou, en mode mains-libres, inséré dans un support, le LS1900 est synonyme de confort et de simplicité d’emploi pendant de longues heures d’utilisation. Remarque : Sauf mention particulière, le terme LS190xx désigne toutes les versions du lecteur.
Composants du lecteur de la série LS1900 DEL Beeper
Fenêtre de sortie
Gâchette (modèle LS190xT uniquement)
Installation du câble d’interface 1.
Branchez le connecteur modulaire du câble d’interface au port correspondant sur la partie inférieure de la poignée du lecteur de la série LS1900.
Port du câble d’interface
2. 3.
Connecteur modulaire du câble
Connectez l’autre extrémité du câble à l’ordinateur central. Branchez l’alimentation au câble (si nécessaire).
5
Page 8
S é r i e L S 1 9 0 0
4.
Lisez les codes à barres correspondants à la page 42 pour communiquer avec l’ordinateur central.
Dépose du câble d’interface Débranchez le connecteur modulaire du câble d’interface installé en appuyant sur le clip du connecteur avec l’extrémité d’un tournevis.
Visée Remarque : On obtient les meilleures performances de décodage lorsque le lecteur n’est pas totalement perpendiculaire au code à barres. 2. Risque de réflection spéculaire
1. Lecture réussie
3. Lecture réussie
65° 6
65° 6
La zone grisée représente un 4 (± 4º) angle mort
Faisceau de lecture
Faisceau de lecture
Code à barres Code à barres
Code à barres
Lecture en mode portable 1. 2.
3.
4.
Vérifiez tous les branchements. Pointez le lecteur sur le code à barres. (Si votre lecteur est muni d’une gâchette, visez, puis appuyez sur la gâchette). Assurez-vous que le faisceau de lecture recouvre toutes les lignes et tous les espaces qui composent le code. CORRECT
INCORRECT
012345
012345
Lorsque le décodage est réalisé, le lecteur émet un bip sonore et le témoin vire au vert.
6
Page 9
G u i d e u t i l i s a t e u r
Lecture en mode mains-libres (LS1902x et LS1908x uniquement) Lorsqu’il est inséré dans son support, le lecteur est activé en permanence. Lorsque vous l’extrayez de son support, il se replace en mode portable normal (c’est-à-dire activé en permanence ou au moyen de la gâchette, selon le modèle). 1.
2.
3.
Insérez le lecteur dans son support. Présentez le code et assurez-vous que le faisceau de lecture recouvre toutes les lignes et tous les espaces qui le composent. Lorsque le décodage est réalisé, le lecteur émet un bip sonore et le témoin vire au vert.
Dépannage Problème
Cause probable
Solutions possibles
Vous avez suivi les instructions d’utilisation, mais rien ne se produit.
Le lecteur n’est pas alimenté.
Vérifiez l'alimentation du système. Assurez-vous que l’alimentation est raccordée si votre configuration l’utilise.
Les câbles d’interface/ d’alimentation sont mal branchés.
Vérifiez que les câbles sont correctement branchés.
7
Page 10
S é r i e L S 1 9 0 0
Problème
Cause probable
Solutions possibles
Le faisceau est activé mais le code n’est pas déchiffré.
Le lecteur n’est pas programmé pour le bon type de code à barres.
Assurez-vous que le lecteur est programmé pour accepter le type de code à barres que vous tentez de lire.
Le code à barres est illisible.
Vérifiez que le code à barres est en bon état. Essayez de lire des codes du même type.
(Suite)
Distance incorrecte entre le lecteur et le code à barres.
Rapprochez ou éloignez le lecteur du code à barres.
Le code est lu mais il n’est pas transmis à l’ordinateur central.
Le lecteur n’est pas programmé pour le type d’ordinateur qui convient.
Lisez le code à barres correspondant à l’ordinateur en question.
8