Page 1
LS 1220 Quick Reference • Guide utilisateur • Kurzübersicht • Guida rapida • Guía rapida • Quick Reference • Guide utilisateur • Kurzübersicht • Guida rapida • Guía rapida • Quick Reference • Guide utilisateur • Kurzüber sicht • Guida rapida • Guía rapida • Quick Reference • Guide utilisateur • Kurzübersicht • Guida rapida • Guía rapida • Quick Reference • Guide utili sateur • Kurzübersicht • Guida rapi da • Guía rapida • Quick Reference • Guide utilisateur • Kurzübersicht • Guida rapida • Guía rapida • Quick Reference • Guide utilisateur • Kur zübersicht • Guida rapida • Guía rap ida • Quick Reference • Guide utilisa teur • Kurzübersicht • Guida rapida • Guía rapida • Quick Reference • Guide utilisateur • Kurzübersicht • Guida rapida • Guía rapida • Quick Refer ence • Guide utilisateur • Kurzüber sicht • Guida rapida • Guía rapida • Quick Reference • Guide utilisateur • Kurzübersicht • Guida rapida • Guía rapida • Quick Reference •
Quick Reference
Page 2
© 2001 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license exists only for equipment, circuits, and subsystems contained in Symbol products. Symbol and the Symbol logo are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No. 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,947; 6,036,098; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297; 6,068,190; 6,082,621; 6,084,528; 6,088,482; 6,092,725; 6,101,483; 6,102,; 6,104,620; 6,114,712; 6,115,678; 6,119,944; 6,123,265; 6,131,814; 6,138,180; 6,142,379; 6,172,478; 6,176,428; 6,178,426; 6,186,400; 6,188,681; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581; D414,171; D414,172; D418,500; D419,548; D423,468; D424,035; D430,158; D430,159; D431,562; D436,104. Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan). European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713. rev. 04/01
Quick Reference
Page 3
1
Set Up The LS 1220 can be triggered either by a software trigger command, or by an external switch. Available from Symbol is a photo detector (p/n 50-13700-025), a push button switch (p/n 25-04950-01) and a foot switch (p/n 25-04951-02). If your LS 1220 came without a host cable, or if you are constructing you own external triggering switch, consult the LS 1220 Product Reference Guide. To connect your LS 1220: • Plug the 25-pin D-connector into the appropriate RS-232C port on your host terminal. • Plug the 9-pin D-connector into the LS 1220. • If using an external switch, plug it into the female stereo connector on the flying lead of the 9-pin D-connector. • Plug the output cable from the power supply into the receptacle on the side of the 25-pin Dconnector.
Page 4
2
Set Up • Plug the power supply into an appropriate AC receptacle. • If host powered, a separate power supply is not required. • Check all connections to be sure they are secure. • Program your LS 1220. Triggering option bar codes begin on page 6. Refer to the LS 1220 Programmer’s Guide for more information on selecting specific parameters.
Quick Reference
Page 5
3
Scanning Made Easy Ready Before you use the scanner, make sure all cable connections are secure.
Test When you trigger the unit, the scan beam is energized for approximately 1 second. A two button switch is required to activate the aiming beam in long range models.
Scan Make sure the bar code is within the scanning range. Align the bar code and trigger the unit. The scanner has read the symbol when the green DECODE LED lights.
Page 6
4
Aiming Tips Scan the Entire Symbol • The scan beam must cross every bar and space on the symbol. • The larger the symbol, the farther away you should hold it from the scanner. • When the bars on the symbol are close together, hold the symbol closer to the scanner. RIGHT
012345
WRONG
012345
Quick Reference
Page 7
5
Aiming Tips Position at an Angle Do not position the scanner exactly perpendicular to the bar code being scanned. In this position, light can bounce back into the scanner’s exit window, and possibly prevent a successful decode.
Long Range Long Range models have an aiming mode to facilitate accuracy over a longer distance. Consult the LS 1220 Product Reference Guide for more information.
Page 8
6
Triggering Options The LS 1220 can be energized in any of seven ways. To select a specific option, scan the associated bar code beginning on page 40.
Level A trigger pull or external switch closure activates the laser and decode processing. The laser remains on, and decode processing continues until a trigger release, a valid decode, or the Laser On Time-out is reached.
Host The host sends a Laser On command. The laser remains on and decode processing occurs until a good decode, the Laser On Time-out is reached, or the host sends a Laser Off command.
Pulse A trigger pull activates the laser and decoding processing. The laser remains on and decode processing continues until a valid decode or the Laser On Time-out is reached.
Next New Code The LS 1220 decodes and transmits information, then waits until a new code is detected before transmitting again.
Quick Reference
Page 9
7
Triggering Options Continuous Level The laser is always on. Decode processing begins with an activation and continues until a good decode, the activation ceases, or the Laser On Time-out is reached.
Constant Scan & Report Laser is always on and decoding. This option is not recommended when programming the scanner with bar code menus.
Continuous Pulse The laser is always on. Decode processing begins with an activation and continues until a good decode, or the Laser On Time-out is reached.