For the Symbol iPOS TC

Page 17

Chapter 2 Setting Up the iPOS TC System Introduction This chapter provides information on installing the iPOS TC, including: • connecting to a POS host device

• installing peripherals

• installing and replacing the screen guard

• mounting the terminal on a counter or tabletop.

2-1

Page 18

iPOS TC Product Reference Guide

Installing the iPOS TC System The following items are required to install the iPOS TC system, and are provided with the terminal: Table 2-1. Connection Items Connection

Cables/Parts Required

LAN On-board Ethernet

Ethernet cable

PCMCIA

PCMCIA card Ethernet cable HDB15/power jack cable (if single channel connection or USB dual channel) AC power adapter

Host

2-2

Host via RS-232

HDB15/DB9 serial cable AC power adapter

Host via RS-485

HDB15/SDL serial cable

Host via USB

USB/USB cable HDB15/power jack cable AC power adapter

Page 19

Setting Up the iPOS TC System

RS-232 Installation To install the iPOS TC in an RS-232 configuration: 1. Shut off power on the POS host device. 2. Plug the serial cable’s 15-pin connector (HDB15) into the serial port on the back of the iPOS TC. 3. Plug the serial cable’s 9-pin connector (DB9) into a serial port (typically COM1) on the POS host device. 4. Insert the male connector on the AC power adapter cable into the port on the back of the serial cable’s 9-pin connector (DB9). 5. Connect the end of the AC adapter to a standard 120V, 60 Hz AC power outlet. 6. Power on the POS host device. The iPOS TC autoconfigures to RS-232. iPOS TC

POS Host Device HDB15 Connector DB9 Connector

AC Power Adapter Male Connector

Figure 2-1. RS-232 Configuration

2-3

Page 20

iPOS TC Product Reference Guide

RS-485 Installation To install the iPOS TC in an RS-485 configuration: 1. Shut off power on the POS host device. 2. Plug the serial cable’s 15-pin connector (HDB15) into the serial port on the back of the iPOS TC. 3. Plug the SDL connector into one of the following ports on the POS host device: 4B, 9A, 9B, or 9E. 4. Turn on the POS host device. The iPOS TC autoconfigures to RS-485. iPOS TC

HDB15 Connector POS Host Device

SDL Connector

Figure 2-2. RS-485 Configuration

2-4

Page 21

Setting Up the iPOS TC System

USB Installation The iPOS TC connects to a USB-enabled PC or POS host device, and behaves as a USB peripheral device. To install the iPOS TC in a USB configuration: 1. Shut off power on the POS host device. 2. Insert one end of the USB cable into the USB port on the back of the iPOS TC. 3. Insert the other end of the USB cable into the USB port on the POS host device. 4. Plug the power jack cable’s 15-pin connector (HDB15) into the serial port on the back of the iPOS TC. 5. Connect the other end of the power jack cable to the male connector on the AC power adapter. 6. Connect the end of the AC adapter to a standard 120V, 60 Hz AC power outlet. 7. Turn on the POS host device.

Power Jack Cable

Figure 2-3. USB Configuration

2-5

Page 22

iPOS TC Product Reference Guide

Connecting Peripherals To connect a peripheral device to the iPOS TC, use an RS-232 or RS-485 auxiliary Y-cable that splits at the HDB15 connector: 1. Plug the cable’s 15-pin connector (HDB15) into the serial port on the back of the iPOS TC. 2. Plug one end of the Y-cable into a serial port (typically COM1) on the POS host device. 3. Connect the other end of the Y-cable to the peripheral device. The peripheral requires its own power supply.

HDB-15

Figure 2-4. Auxiliary Cable Peripheral Connection

2-6

Page 23

Setting Up the iPOS TC System

Installing the Screen Guard The screen guard protects the iPOS TC's screen from typical wear such as scratches and spills. Replace the screen guard when excessive scratches are visible or if a liquid is spilled on the screen. This maintenance extends the operation of the iPOS TC. To install the screen guard onto the iPOS TC: 1. Disconnect power from the iPOS TC. 2. Clean the surface of the terminal and touchscreen using a cloth dampened with non-abrasive glass cleaner. Do not spray liquid directly onto the terminal. Wait until the terminal and glass are completely dry. 3. On the back of the screen guard, remove the paper adhesive guard.

Figure 2-5. Removing Adhesive Guard

2-7

Page 24

iPOS TC Product Reference Guide

4. Place the adhesive side down onto the graphical screen overlay, carefully aligning the edges. Apply gentle pressure to the screen guard to ensure proper adhesion. The screen guard can be removed and repositioned in case of misalignment.

Figure 2-6. Placing Screen Guard on Terminal

Replacing the Screen Guard To replace the screen guard, carefully remove the worn guard from the terminal by peeling from the upper-left corner of the guard. Do not remove the graphical screen overlay underneath the guard.

Figure 2-7. Removing Screen Guard 2-8

Page 25

Setting Up the iPOS TC System

Follow the procedure in Installing the Screen Guard to install the new screen guard.

Mounting the iPOS TC The iPOS TC can be mounted on a counter or tabletop using the following items: • mounting plate

•

3 bolts or posts

•

3 nuts

•

3 washers.

To secure the iPOS TC to a tabletop: 1. Attach the mounting plate to the table surface using the 3 bolts, nuts, and washers. Leave approximately ¼ to ½ inch between the washer and the bolt head. 2. Position the holes on the bottom of the iPOS TC over the bolt heads and slide to secure.

Figure 2-8. Mounting the iPOS TC 2-9

Page 26

iPOS TC Product Reference Guide

2-10