Page 41

Chapter 3 LAN Manager 2.1 Setup Before starting the setup for the FMT1000 Series, beginning on page 3-3, the remote boot service should be installed on the server. We recommend that you read the procedures on activation of the LAN Manager server that are documented in the LAN Manager Administrator's Guide, chapter 13. Unlike with NetWare or LANtastic, no boot image disk is generated for the LAN Manager installation. Instead, LAN Manager constructs an emulated disk on-the-fly using information about the particular workstation found in setup files on the server. Consequently, after the server setup is complete, some setup files require modification. To modify the files follow these steps: 1. Copy the NDIS driver (LP_NDIS.EXE) from the network driver disk to C:\LANMAN\RPL\BBLOCK\NDIS on the server. Create the directory: C:\LANMAN\RPL\BBLOCK\NETBEUI\FMT1000

Under this directory, copy DOSBB.CNF and PROTOCOL.INI for the FMT1000 network driver disk. 2. Some versions of NETBEUI.EXE attempt to execute 80286 instructions, causing the computer to crash. Avoid this by using version 2.1 of NETBEUI.EXE. Contact LAN Manager for information regarding how to download NB_21.EXE from the Microsoft Developer's BBS. 3. In the directory C:\LANMAN\RPL\, make backup copies of the files RPL.MAP and RPLMGR.INI.

3-1

Page 42

FMT 1000 Series Remote Boot Setup

4. Edit C:\LANMAN\RPL\RPL.MAP by including a boot record: yyyyyyyyyyyy BBLOCK\NETBEUI\FMT1000\DOSBB.CNF 2 6 A~ DOS~FMT1000~LPC3xxx 00c052 ~ ,,, ~ RDOS ~ ~ ~ ~ ~ ~ and add a new default DOS workstation record: 00c052?????? ???????? D FITS\DEFAULT (RPL_SERVER_NAME) S ~ ~ ~ ,,, ~ RDOS ~ DEFAULT *~NEW~DOS~FMT1000~*

The file RPL.LP on the network driver disk contains these records. Note: The two lines above adding a new default workstation should be entered as one line without entering a hard return. The single line will begin with “00c052” and end with “~ RDOS ~”. 5. Edit C:\LANMAN\RPL\RPLMGR.INI so that RPLMGR can recognize the adapter. The header comments at the beginning of this file document the meaning and usage of different entries in the configuration block. Under the four configuration sections identified as: name=default name=DOS330 name=DOS401 name=DOS500 add the string: |00c052??????

to the adapter= entry. Optionally, you may create new configuration sections for specific versions of DOS and allow for FMT1000 specific profiles in the event other types of diskless workstations will be supported. See the LAN Manager Administrator's Guide for more details.

3-2

Page 43

LAN Manager 2.1® Setup

6. At the OS/2 command line type RPLINST. This will activate the changes made to RPL.MAP and RPLMGR.INI. 7. At the OS/2 command line type NET START RPL. This will start RPL on the server with the new setup information. 8. Create a profile. 9. Attach a station to a profile. Note: See Chapter 13, LAN Manager Administrator’s Guide for more details on setting up this resource. Now that the server setup is complete, power up the unit, enter setup, and select RIPL as the boot type. Upon exiting setup the unit should boot from the server. We recommend having a CGA CRT connected the first time booting is attempted. The CGA CRT will display status messages. The FMT1000 Series 2x40 LCD will not. Assuming a CRT is connected to the FMT1000 Series computer, status lines appear on the CRT similar to: Searching for DLC RPL Server, retries = 000001

Sending file requests to DLC RPL Server, retries = 000001 Waiting for data frame with sequence number: 000044 Elapsed time: 00:00:02

Within a few seconds, this screen clears and informational messages appear concerning files that are being loaded from the server. Once the unit has been successfully booted, you may wish to customize the settings in CONFIG.SYS and AUTOEXEC.BAT files to include loading of HIDOS.SYS (FMT1000 HMA driver). More information on these files is found in the FMT1000 Series Programmer's Manual.

3-3

Page 44

FMT 1000 Series Remote Boot Setup

3-4

Page 45

Chapter 4 Demonstration Program When the FMT1000 Series computer is ready for boot, apply power to the unit. After a self-test period, the computer emits three rapid beeps and attempts to boot from the network server or the floppy. Once the system is booted, a DOS prompt appears. At this prompt, run the BASIC interpreter by typing its filename. Load the demo application and run it. This program is shipped on diskette with FMT1000 Series computers. The program listed below is written in MS-DOS QBasic. The program will work with the DOS 5.0 BASIC interpreter. REM ***** Program: FMT1000 QUICK DEMO ***** REM (C) 1995 1995 Symbol Technologies Inc. All Rights Reserved REM Modification of this program encouraged. REM **************************************** CLS PRINT “Congratulations!” PRINT “Your FMT1000 is now set up!” PLAY “T180L802CEG03C02P8G03L2C” SLEEP 5 CLS PRINT “Enter your name below:” LINE INPUT name$ CLS PRINT “You entered:” PRINT name$; SLEEP 2 CLS OPEN “COM2:9600,N,8,1,LF” FOR RANDOM AS #1 PRINT #1, “RVR” PRINT “Press enter to continue:” LINE INPUT ver$ CLS PRINT “Scan barcode #1 and then press enter.”

4-1

Page 46

FMT 1000 Series Remote Boot Setup Guide

LINE INPUT bar$ CLS IF bar$ = “3852” THEN PRINT “Barcode scanned OK: “ ELSE PRINT “Barcode scan error.” ENDIF PRINT bar$; SLEEP 2 CLS PRINT “Scan barcode #2 and then press enter.” LINE INPUT bar$ CLS IF bar$ = “SYMBOL” THEN PRINT “Barcode scanned OK: “ ELSE PRINT “Barcode scan error.” ENDIF PRINT bar$; SLEEP 2 PRINT “Your FMT1000 works!” PLAY “T1808C16C8D8D7D7A” SLEEP 2 CLOSE #1 END

4-2

Page 47

Demonstration Program

The bar codes used in the demonstration program are found below. The first is a Two of Five Interleaved Code that shows the numbers “3852”. The second is a Code 39 that shows “Symbol.”

2 QUIET ZONE

8

5

STOP

START

QUIET ZONE

3

Interleaved Two of Five Bar Code”3852”

Barcode #2, Code 39"Symbol”

The simple example above is meant as a starting point for further exploration of the FMT1000 Series environment. Try modifying the program above to include I/O commands or disk access. For additional programming examples and information, consult the FMT1000 Series Computer Programmer's Guide.

4-3

Page 48

FMT 1000 Series Remote Boot Setup Guide

4-4

Page 49

Appendix A BIOS Setup Once the FMT1000 Series computer is booted, the Ethernet address and BIOS revision level appear on the first line of the 2-line by 40-character display. The second line displays “[ENTER]=setup” even if setup has been disabled. Figure A-1 shows a sample after-boot display. Unique Network Address

00-C0-52-xx-xx-xx [ENTER]=setup

BIOS Revision xx.xx

Specific Address & BIOS Version Numbers

Figure A-1. First Screen Display after Bootup

A delay of a few seconds occurs before the system finishes the boot process. To enter into the setup process, the <ENTER> key must be pressed while the address and revision are displayed.

A-1

Page 50

FMT 1000 Series Remote Boot Setup Guide

Figure A-2 shows a sample setup screen. Line 1 of the display indicates which setup screen and option are currently selected. Line 2 shows the currently saved options. The <ENTER> key accepts a setting and advances to the next setup screen. Option

Memory Option: A (640K Conv, 256K Ext) [ENTER]ACCEPTS [F8]Toggles [A ]

Saved Option

Figure A-2. Memory Options Screen Using <F8> Key To Toggle Between Options

Pressing the following keys moves you through the setup screens and their option lists:

A-2

<F5>

Moves you backward through setup screens without change.

<F6>

Moves you forward through setup screens without change.

<F7>

Moves you backward through option list.

<F8>

Moves you forward through option list.

<ENTER>

Accepts option setting and advances you to next setup screen.