Page 11

NetWare Remote Reset

THREE-STAGE AUTOEXEC.BAT COMMAND PROCESSING SEQUENCE (FFRPL) (1)–––––––––––––––––––––>

(2)–––––––––––––––––––––>

(3)–––––––––––––––––––––>

AUTOEXEC.BAT in Boot Image File

AUTOEXEC.BAT in SYS.LOGIN

AUTOEXEC.BAT in FMT1000 HOME directory

LSL

LSL

LSL

LPNICE

LPNICE

LPNICE

IPXODI

IPXODI

IPXODI

NETX

NETX

NETX

LOGIN FMT1000

LOGIN FMT1000 PROMPT $p$g . . .

THREE-STAGE AUTOEXEC.BAT COMMAND PROCESSING SEQUENCE (IPX) (1)–––––––––––––––––––––>

(2)–––––––––––––––––––––>

(3)–––––––––––––––––––––>

AUTOEXEC.BAT in the Boot Image File

AUTOEXEC.BAT in SYS.LOGIN

AUTOEXEC.BAT in FMT1000 HOME directory

LSL

LSL

LSL

RPLODI

RPLODI

RPLODI

LPNICE

LPNICE

LPNICE

IPXODI

IPXODI

IPXODI

NETX

NETX

NETX

LOGIN FMT1000

LOGIN FMT1000 PROMPT $p$g . . .

1-3

Page 12

FMT 1000 Series Remote Boot Setup Guide

REMOTE RESET BOOT PROCESS The FMT1000 Series Computer

The Server

(1) Power Up FMT1000 Series Computer 00-C0-52-xx-xx-xx [ENTER]=setup

BIOS Revision xx.xx

(2) Protocol specific boot request is broadcast by FMT1000 Series Computer

(3) Server downloads boot image file, NET$DOS.SYS, created by DOSGEN, and executes AUTOEXEC.BAT file located in NET$DOS.SYS...

(5) LOGIN FMT1000

(7) F:\FMT1000

(4) Execution is shifted to the AUTOEXEC.BAT in SYS:LOGIN after executing NETX (6) Execution passes to the AUTOEXEC.BAT file in the user’s HOME directory after user logs onto the network.

Multiple computers may use the same boot image file. If you want your computers to use different image files, or you have other diskless nodes on your network, you need to refer to your Novell documentation regarding DOSGEN before you continue.

1-4

Page 13

NetWare Remote Reset

NetWare 3.11 Server Setup 1. Follow this step only for FFRPL boot type. From a workstation, log onto the system as Supervisor: C:\LOGIN SUPERVISOR

Map drives to the system and login directories: E:\>MAP F:=SYS:SYSTEM E:\>MAP G:=SYS:LOGIN

Place the driver disk in drive A and copy the files: E:\>COPY A:\NOVSUP\RPL.NLM F: E:\>COPY A:\NOVSUP\RBOOT.RPL G:

2. Check/modify the server setup. At the server, run the editor to examine the system startup batch file: :LOAD EDIT SYS:SYSTEM\AUTOEXEC.NCF

For IPX boot type, you need lines similar to: LOAD NE2000 port=320 int=5 frame=ETHERNET_802.3 BIND IPX TO NE2000 net=FBFB1

For FFRPL boot type, you need to see lines similar to: LOAD NE2000 port=320 int=5 frame=ETHERNET_802.2 BIND IPX TO NE2000 net=FBFB2 LOAD RPL BIND RPL TO NE2000

If you have the correct information, exit edit by pressing the <ESC> key. Proceed to Step 3. If you need to modify the file, add the appropriate lines to the bottom of the file using the following format.

1-5

Page 14

FMT 1000 Series Remote Boot Setup Guide

To add an IPX PROTOCOL, add these two lines to the AUTOEXEC.NCF file: LOAD <netdriver> <parameters> frame=<protocol-type> BIND IPX TO <netdriver> [<parameters>] net=<netnumber>

To add an RPL PROTOCOL to an ETHERNET_802.2 frame type, add these two lines to the AUTOEXEC.NCF file: LOAD RPL BIND RPL TO <netdriver> <parameters>

Where: <netdriver> is the Network Board Driver Name, e.g. NE2000; <parameters> are board specific parameters, check your board documentation to see what is required. For example, [port=320 int=5 frame=ETHERNET_802.2]; <protocol_type> must be ETHERNET_802.2 for FFRPL and ETHERNET_802.3 for IPX; <netnumber> must be a unique sub-network number assigned to this protocol. Choose any number not used elsewhere on the Novell network. When you have completed your changes, press <ESC> to exit the editor and press <YES> to save the changes. To invoke your changes, you need to down the server and bring it back up.

1-6

Page 15

NetWare Remote Reset

3. Use the monitor utility to confirm that the LAN information is correct for the selected frame type. :LOAD MONITOR

Netware v3.11 (5 user) - 8/9/91

Netware 386 Loadable Module

Information For Server SERVER1 File Server Up Time:

0 Days

Utilization 3 Original Cache Buffers: 1,666 Total Cache Buffers: 1,309 Dirty Cache Buffers: 0 Current Disk Requests 0

23 Hours 54 Minutes

0 Seconds

Packet Receive Buffers Directory Cache Buffers Service Processes Connections In Use: Open Files

10 38 2 4 0

Available Options

Connection Information Disk Information LAN Information System Module Information Lock File Server Console File Open / Lock Activity Resource Utilization Exit

First Screen in Response To The Load Monitor Command

Highlight LAN Information from the Available Options menu and press <ENTER>.

1-7

Page 16

FMT 1000 Series Remote Boot Setup Guide

Netware v3.11 (5 user) - 8/9/91

Netware 386 Loadable Module

Information For Server SERVER1 File Server Up Time:

0 Days

23 Hours

Utilization 3 Original Cache Buffers: 1,666 Total Cache Buffers: 1,309 Dirty Cache Buffers: 0 Current Disk Requests 0

54 Minutes

0 Seconds

Packet Receive Buffers Directory Cache Buffers Service Processes Connections In Use: Open Files

Available Options LAN Driver Information Connection Information NE2000[port=300 int=5 frame=ETHERNET_802.2 Disk Information NE2000[port=300 int=5 frame=ETHERNET_802.3 LAN Information System Module Information Lock File Server Console File Open / Lock Activity Resource Utilization Exit

Second Screen in Response To Selection of LAN Information

Highlight the frame type 802.2 or 802.3. • If you choose 802.3 for IPX boot type, see page 9. • If you choose 802.2 for FFRPL boot type, see page 10.

1-8

10 38 2 4 0

Page 17

NetWare Remote Reset

Netware v3.11 (5 user) - 8/9/91 Information For Server SERVER1 File Server Up Time:

0 Days

Utilization 3 Original Cache Buffers: 1,666 Total Cache Buffers: 1,309 Dirty Cache Buffers: 0 Current Disk Requests 0

23 Hours

54 Minutes

0 Seconds

Packet Receive Buffers Directory Cache Buffers Service Processes Connections In Use: Open Files

10 38 2 4 0

Netware 386 Loadable ModNE2000 [PORT=500] INT=5 FRAME=ETHERNET_802.3 LAN Driver Information Version 3.1 NE2000[port=300 int=5 frame=ETHERNET_802.2 Node Address: 0000CO56185C NE2000[port=300 int=5 frame=ETHERNET_802.3 Protocols IPX Network Address: 00BBB8023 tGeneric Statistics

Third Screen in Response to Selection of ETHERNET_802.3

IPX Boot Type As a minimum, the IPX protocol must be bound to the 802.3 frame type.

1-9

Page 18

FMT 1000 Series Remote Boot Setup Guide

Netware v3.11 (5 user) - 8/9/91

Information For Server SERVER1 File Server Up Time:

0 Days

23 Hours

Utilization 3 Original Cache Buffers: 1,666 Total Cache Buffers: 1,309 Dirty Cache Buffers: 0 Current Disk Requests 0

54 Minutes

0 Seconds

Packet Receive Buffers Directory Cache Buffers Service Processes Connections In Use: Open Files

10 38 2 4 0

Netware 386 Loadable ModNE2000 [PORT=500] INT=5 FRAME=ETHERNET_802.2 LAN Driver Information Version NE2000[port=300 int=5 3.1 frame=ETHERNET_802.2 Node Address: 0000COE71E5C NE2000[port=300 int=5 frame=ETHERNET_802.3 Protocols RPL IPX Network Address: 000000B tGeneric Statistics

Third Screen in Response to Selection of ETHERNET_802.2 for FFRPL Boot Type

FFRPL Boot Type As a minimum, the IPX and RPL protocols must be bound to the 802.2 frame type. Exit the utility by pressing <ESC> three times or until Exit Monitor appears in the window. Select Yes and press <ENTER>.

1-10

Page 19

NetWare Remote Reset

Create a Boot Image File: NET$DOS.SYS 1. Create the boot disk. From a workstation on the network, insert an unformatted disk in drive A. (Your drive letter may be different.) From a workstation, log onto the system as Supervisor: Format the disk as a system disk: C:\>FORMAT A: /S

2. Create batch and system files on the boot disk. Using a text editor, create CONFIG.SYS, NET.CFG, and AUTOEXEC.BAT files on the boot disk. The contents for the CONFIG.SYS file should be: FILES = 20 BUFFERS = 25 LASTDRIVE = E

The contents for the NET.CFG file should be: LINK DRIVER LPNICE <TAB>FRAME <protocol_type>

Where <protocol_type> is replaced with either "ETHERNET_802.2" for FFRPL or "ETHERNET_802.3" for IPX. For the FFRPL boot type, the contents of the AUTOEXEC.BAT file should be: LSL LPNICE IPXODI NETX

For the IPX boot type, the contents of the AUTOEXEC.BAT file should be: LSL RPLODI LPNICE IPXODI NETX 1-11

Page 20

FMT 1000 Series Remote Boot Setup Guide

Note: The difference between the FFRPL and IPX AUTOEXEC.BAT file contents is the addition of the RPLODI as the second line for the IPX boot type in the AUTOEXEC.BAT file. 3. Copy the drivers from the network driver disk to the boot disk. Place the boot disk in drive A and the network driver disk in Drive B. (Your drive letters may be different.) C:\>COPY B:\NOVSUP\IPXODI.COM A: C:\>COPY B:\NOVSUP\LSL.COM A: C:\>COPY B:\NOVSUP\NETX.EXE A: C:\>COPY B:\ODI\LPNICE.COM A:

For the IPX boot type, you will need to copy one more file. C:\>COPY B:\RPLKTI\RPLODI.COM A:

4. Create a user account named, e.g., "FMT1000" and map directories as needed. (Choose a name appropriate to the specific FMT1000 product you are using.) Run the Novell SYSCON utility and create a user account “FMT1000”. Note: User FMT1000 should be set up as any other user on the network. It should have an assigned home directory with rights to that directory. A login script should be created with appropriate directory mappings and an appropriate COMPSPEC setting. When automatically running applications, passwords should not be assigned. See NetWare v3.11 Installation Manual Network Setup and Appendix A: Login Script Commands, for additional information. 5. Map drive letters for use during the DOSGEN process. Check which drive letters are available for mapping on the workstation. The drive letters to be mapped should not be in use. This example uses F: as the first unused drive letter. Depending on how your system is set up, your drive letters may be different.

1-12