Page 63
I/O Processor Command Quick Reference
SBA
SET BAUD AUX COMM 0 = 300 BAUD 1 = 600 BAUD 2 = 1200 BAUD 3 = 2400 BAUD 4 = 4800 BAUD 5 = 9600 BAUD* 6 = 19200 BAUD
SBE
SET BATTERY SENSE ENABLE 0 = DISABLE * 1 = ENABLE
SBH
SET BAUD HOST COMM 0 = 300 BAUD 1 = 600 BAUD 2 = 1200 BAUD 3 = 2400 BAUD 4 = 4800 BAUD 5 = 9600 BAUD* 6 = 19200 BAUD
SBL
SET BACKLIGHT MODE 0 = OFF 1 = ON 2 = AUTO*
SBP†
SET BEEPER 0 = HI 1 = HILO 2 = HIHI 3 = HILOHI 4 = HIHIHI 5 = TICK
B-9
Page 64
FMT1040 Installation Guide
SBS
SET ON BATTERY RESPONSE STRING DEFAULT = “[ON BATTERY]”, DEFINABLE UP TO 16 CHARACTERS
SCB
SET CODABAR MODE 0 = OFF 1 = ON*
SCD
SET KEYBOARD INTERCHARACTER DELAY XXX -> XXX * 10 MILLISECONDS (0 - 2.55 SECONDS)
SCM
RETURN CONCATENATE MODE
SCM
SET CONCATENATE MODE 0 = OFF* 1 = ON
SDA
SET DATA BITS/PARITY AUX COMM 0 = 7 BITS, EVEN PARITY 1 = 7 BITS, ODD PARITY 2 = 7 BITS, SPACE PARITY 3 = 7 BITS, MARK PARITY 4 = 8 BITS, EVEN PARITY 5 = 8 BITS, ODD PARITY 6 = 8 BITS, NO PARITY*
SDE
SET DIGITAL I/O ENABLE 0 = OFF 1 = ON*
B-10
Page 65
I/O Processor Command Quick Reference
SDH
SET DATA BITS/PARITY HOST COMM 0 = 7 BITS, EVEN PARITY 1 = 7 BITS, ODD PARITY 2 = 7 BITS, SPACE PARITY 3 = 7 BITS, MARK PARITY 4 = 8 BITS, EVEN PARITY 5 = 8 BITS, ODD PARITY 6 = 8 BITS, NO PARITY*
SDP
SET DIGITAL I/O PREFIX CHARACTERS
SDS
SET DIGITAL I/O SUFFIX CHARACTERS
SDT
SET DIGITAL I/O TAG STRING
SEA
SET AUTOENTER MODE AUX 0 = OFF* 1 = CR 2 = CR\LF 3 = TAB
SED
SET AUTOENTER MODE DIGITAL I/O 0 = OFF* 1 = CR 2 = CR\LF 3 = TAB
SEE†
WRITE SETUPS TO EEPROM (ONE BEEP GENERATED IF WRITE TO EEPROM IS SUCCESSFUL)
SEI
SET AUTOENTER MODE INTERNAL 0 = OFF* 1 = CR 2 = CR\LF 3 = TAB
B-11
Page 66
FMT1040 Installation Guide
SEP
SET AUTOENTER MODE PERIPHERAL 0 = OFF* 1 = CR 2 = CR\LF 3 = TAB
SFD†
SET TO FACTORY DEFAULTS (ONE BEEP GENERATED IF WRITE TO EEPROM IS SUCCESSFUL)
SHA
SET HANDSHAKE AUX COMM 0 = NONE 1 = XON/XOFF* 2 = RTS/CTS
SHH
SET HANDSHAKE HOST COMM 0 = NONE 1 = XON/XOFF*
SI1
SET INPUT 1 RESPONSE STRING
SI2
SET INPUT 2 RESPONSE STRING
SIB
SET AUX COMM INPUT BEEP ENABLE 0 = OFF 1 = ON*
SIC†
SET AUX COMM INPUT CANCEL
SII†
SET AUX COMM INPUT BUFFER INITIALIZE
SIM
SET AUX COMM INPUT STRING MAXLEN
B-12
Page 67
I/O Processor Command Quick Reference
SIO
SET AUX COMM INPUT TIMEOUT XXX -> XXX * 1 SECOND (0 - 255 SECONDS)
SIP
SET INTERNAL PREFIX CHARACTERS
SIR
SET AUX COMM INPUT READ MODE 0 = ONE READ 1 = CONTINUOUS READS
SIS
SET INTERNAL SUFFIX CHARACTERS
SIT
SET INTERNAL TAG STRING
SKC
SET KEYBOARD CLICK 0 = OFF 1 = ON*
SKE
SET KEYBOARD ENABLE 0 = OFF 1 = ON*
SKH
SET KEYBOARD HARDWARE RESET ENABLE 0 = OFF 1 = ON*
SKR
SET KEYBOARD REPEAT 0 = OFF 1 = ON*
SKT
SET KEYBOARD TYPE
B-13
Page 68
FMT1040 Installation Guide
0 = FMT1020 QWERTY* 1 = FMT1020 ALPHANUMERIC ABC 2 = FMT1020 NUMERIC 3 = FMT1060 4 = FMT1040 SM1
SET MATCH VALUE FOR COUNTER #1 RANGE FROM 1 TO 1000000
SM2
SET MATCH VALUE FOR COUNTER #2 RANGE FROM 1 TO 1000000
SOC†
SET AUX COMM OUTPUT WRITE CANCEL
SOO
SET AUX COMM OUTPUT WRITE TIMEOUT XXX -> XXX * 1 SECOND (0 - 255 SECONDS)
SOW†
SET AUX COMM OUTPUT WRITE STRING (NO FACTORY DEFAULT)
SP5
SET PERIPHERAL TAG FOR 5-PIN CONNECTOR ANY SINGLE CHARACTER, NO DEFAULT
SP9
SET PERIPHERAL TAG FOR 9-PIN CONNECTOR ANY SINGLE CHARACTER, NO DEFAULT
SPA
SET HOST/AUX COMM PASSTHRU MODE 0 = OFF 1 = ON
SPE
SET PERIPHERAL PORT ENABLE 0 = OFF 1 = ON*
SPI
B-14
SET PREFIX INPUT AUX COMM
Page 69
I/O Processor Command Quick Reference
SPO
SET PREFIX OUTPUT AUX COMM
SPP
SET PERIPHERAL PREFIX CHARACTERS
SPS
SET PERIPHERAL SUFFIX CHARACTERS
SPT
SET PERIPHERAL TAB STRING
SR1
RESET COUNTER 1
SR2
RESET COUNTER 2
SRA
SET RESPONSE PATH FOR AUX COMM PORT 0 = KEYBOARD* 1 = HOST COMM
SRD
SET RESPONSE PATH FOR DIGITAL I/O 0 = KEYBOARD* 1 = HOST COMM
SRI
SET RESPONSE PATH FOR INTERNAL CMMDS 0 = KEYBOARD* 1 = HOST COMM
SRP
SET RESPONSE PATH FOR PERIPHERAL PORT 0 = KEYBOARD* 1 = HOST
SSA
SET STOP BITS AUX COMM 0 = 1 STOP BIT* 1 = 2 STOP BITS
SSB
SET SYMBOLOGY READ BEEP ENABLE 0 = OFF 1 = ON*
B-15
Page 70
FMT1040 Installation Guide
SSH
SET STOP BITS HOST COMM 0 = 1 STOP BIT* 1 = 2 STOP BITS
SSI
SET SUFFIX INPUT AUX COMM
SSM
SET SYMBOLOGY READ STRING MATCH LENGTH
SSO
SET SUFFIX OUTPUT AUX COMM
SSS
SET STARTUP STRING
ST1
SET MOMENTARY TIMEOUT FOR OUTPUT 1 000 = OFF 999 = ON XXX -> XXX * 0.1 SECONDS (0.1 - 99.8 SECONDS)
ST2
SET MOMENTARY TIMEOUT FOR OUTPUT 2 000 = OFF 999 = ON XXX -> XXX * 0.1 SECONDS (0.1 - 99.8 SECONDS)
STC
SET PASSTHRU TERMINATION CHARACTERS
SUP
SET UPC MODE 0 = OFF 1 = ON*
SVA
SET VIEWING ANGLE
† These commands have no corresponding “SET” or “RETURN” command. All other commands have corresponding “SET” or “RETURN” commands. *
B-16
FACTORY DEFAULT