Page 63

I/O Processor Command Quick Reference

SBA

SET BAUD AUX COMM 0 = 300 BAUD 1 = 600 BAUD 2 = 1200 BAUD 3 = 2400 BAUD 4 = 4800 BAUD 5 = 9600 BAUD* 6 = 19200 BAUD

SBE

SET BATTERY SENSE ENABLE 0 = DISABLE * 1 = ENABLE

SBH

SET BAUD HOST COMM 0 = 300 BAUD 1 = 600 BAUD 2 = 1200 BAUD 3 = 2400 BAUD 4 = 4800 BAUD 5 = 9600 BAUD* 6 = 19200 BAUD

SBL

SET BACKLIGHT MODE 0 = OFF 1 = ON 2 = AUTO*

SBP†

SET BEEPER 0 = HI 1 = HILO 2 = HIHI 3 = HILOHI 4 = HIHIHI 5 = TICK

B-9

Page 64

FMT1040 Installation Guide

SBS

SET ON BATTERY RESPONSE STRING DEFAULT = “[ON BATTERY]”, DEFINABLE UP TO 16 CHARACTERS

SCB

SET CODABAR MODE 0 = OFF 1 = ON*

SCD

SET KEYBOARD INTERCHARACTER DELAY XXX -> XXX * 10 MILLISECONDS (0 - 2.55 SECONDS)

SCM

RETURN CONCATENATE MODE

SCM

SET CONCATENATE MODE 0 = OFF* 1 = ON

SDA

SET DATA BITS/PARITY AUX COMM 0 = 7 BITS, EVEN PARITY 1 = 7 BITS, ODD PARITY 2 = 7 BITS, SPACE PARITY 3 = 7 BITS, MARK PARITY 4 = 8 BITS, EVEN PARITY 5 = 8 BITS, ODD PARITY 6 = 8 BITS, NO PARITY*

SDE

SET DIGITAL I/O ENABLE 0 = OFF 1 = ON*

B-10

Page 65

I/O Processor Command Quick Reference

SDH

SET DATA BITS/PARITY HOST COMM 0 = 7 BITS, EVEN PARITY 1 = 7 BITS, ODD PARITY 2 = 7 BITS, SPACE PARITY 3 = 7 BITS, MARK PARITY 4 = 8 BITS, EVEN PARITY 5 = 8 BITS, ODD PARITY 6 = 8 BITS, NO PARITY*

SDP

SET DIGITAL I/O PREFIX CHARACTERS

SDS

SET DIGITAL I/O SUFFIX CHARACTERS

SDT

SET DIGITAL I/O TAG STRING

SEA

SET AUTOENTER MODE AUX 0 = OFF* 1 = CR 2 = CR\LF 3 = TAB

SED

SET AUTOENTER MODE DIGITAL I/O 0 = OFF* 1 = CR 2 = CR\LF 3 = TAB

SEE†

WRITE SETUPS TO EEPROM (ONE BEEP GENERATED IF WRITE TO EEPROM IS SUCCESSFUL)

SEI

SET AUTOENTER MODE INTERNAL 0 = OFF* 1 = CR 2 = CR\LF 3 = TAB

B-11

Page 66

FMT1040 Installation Guide

SEP

SET AUTOENTER MODE PERIPHERAL 0 = OFF* 1 = CR 2 = CR\LF 3 = TAB

SFD†

SET TO FACTORY DEFAULTS (ONE BEEP GENERATED IF WRITE TO EEPROM IS SUCCESSFUL)

SHA

SET HANDSHAKE AUX COMM 0 = NONE 1 = XON/XOFF* 2 = RTS/CTS

SHH

SET HANDSHAKE HOST COMM 0 = NONE 1 = XON/XOFF*

SI1

SET INPUT 1 RESPONSE STRING

SI2

SET INPUT 2 RESPONSE STRING

SIB

SET AUX COMM INPUT BEEP ENABLE 0 = OFF 1 = ON*

SIC†

SET AUX COMM INPUT CANCEL

SII†

SET AUX COMM INPUT BUFFER INITIALIZE

SIM

SET AUX COMM INPUT STRING MAXLEN

B-12

Page 67

I/O Processor Command Quick Reference

SIO

SET AUX COMM INPUT TIMEOUT XXX -> XXX * 1 SECOND (0 - 255 SECONDS)

SIP

SET INTERNAL PREFIX CHARACTERS

SIR

SET AUX COMM INPUT READ MODE 0 = ONE READ 1 = CONTINUOUS READS

SIS

SET INTERNAL SUFFIX CHARACTERS

SIT

SET INTERNAL TAG STRING

SKC

SET KEYBOARD CLICK 0 = OFF 1 = ON*

SKE

SET KEYBOARD ENABLE 0 = OFF 1 = ON*

SKH

SET KEYBOARD HARDWARE RESET ENABLE 0 = OFF 1 = ON*

SKR

SET KEYBOARD REPEAT 0 = OFF 1 = ON*

SKT

SET KEYBOARD TYPE

B-13

Page 68

FMT1040 Installation Guide

0 = FMT1020 QWERTY* 1 = FMT1020 ALPHANUMERIC ABC 2 = FMT1020 NUMERIC 3 = FMT1060 4 = FMT1040 SM1

SET MATCH VALUE FOR COUNTER #1 RANGE FROM 1 TO 1000000

SM2

SET MATCH VALUE FOR COUNTER #2 RANGE FROM 1 TO 1000000

SOC†

SET AUX COMM OUTPUT WRITE CANCEL

SOO

SET AUX COMM OUTPUT WRITE TIMEOUT XXX -> XXX * 1 SECOND (0 - 255 SECONDS)

SOW†

SET AUX COMM OUTPUT WRITE STRING (NO FACTORY DEFAULT)

SP5

SET PERIPHERAL TAG FOR 5-PIN CONNECTOR ANY SINGLE CHARACTER, NO DEFAULT

SP9

SET PERIPHERAL TAG FOR 9-PIN CONNECTOR ANY SINGLE CHARACTER, NO DEFAULT

SPA

SET HOST/AUX COMM PASSTHRU MODE 0 = OFF 1 = ON

SPE

SET PERIPHERAL PORT ENABLE 0 = OFF 1 = ON*

SPI

B-14

SET PREFIX INPUT AUX COMM

Page 69

I/O Processor Command Quick Reference

SPO

SET PREFIX OUTPUT AUX COMM

SPP

SET PERIPHERAL PREFIX CHARACTERS

SPS

SET PERIPHERAL SUFFIX CHARACTERS

SPT

SET PERIPHERAL TAB STRING

SR1

RESET COUNTER 1

SR2

RESET COUNTER 2

SRA

SET RESPONSE PATH FOR AUX COMM PORT 0 = KEYBOARD* 1 = HOST COMM

SRD

SET RESPONSE PATH FOR DIGITAL I/O 0 = KEYBOARD* 1 = HOST COMM

SRI

SET RESPONSE PATH FOR INTERNAL CMMDS 0 = KEYBOARD* 1 = HOST COMM

SRP

SET RESPONSE PATH FOR PERIPHERAL PORT 0 = KEYBOARD* 1 = HOST

SSA

SET STOP BITS AUX COMM 0 = 1 STOP BIT* 1 = 2 STOP BITS

SSB

SET SYMBOLOGY READ BEEP ENABLE 0 = OFF 1 = ON*

B-15

Page 70

FMT1040 Installation Guide

SSH

SET STOP BITS HOST COMM 0 = 1 STOP BIT* 1 = 2 STOP BITS

SSI

SET SUFFIX INPUT AUX COMM

SSM

SET SYMBOLOGY READ STRING MATCH LENGTH

SSO

SET SUFFIX OUTPUT AUX COMM

SSS

SET STARTUP STRING

ST1

SET MOMENTARY TIMEOUT FOR OUTPUT 1 000 = OFF 999 = ON XXX -> XXX * 0.1 SECONDS (0.1 - 99.8 SECONDS)

ST2

SET MOMENTARY TIMEOUT FOR OUTPUT 2 000 = OFF 999 = ON XXX -> XXX * 0.1 SECONDS (0.1 - 99.8 SECONDS)

STC

SET PASSTHRU TERMINATION CHARACTERS

SUP

SET UPC MODE 0 = OFF 1 = ON*

SVA

SET VIEWING ANGLE

† These commands have no corresponding “SET” or “RETURN” command. All other commands have corresponding “SET” or “RETURN” commands. *

B-16

FACTORY DEFAULT