Page 55

Appendix B I/O Processor Command Quick Reference Listed below are the commands that configure the I/O processor board functions, including the beeper, the bar code port, the RS-232 serial smart port, and the digital I/O ports. These commands are sent to the I/O processor board using COM2; thus, any command that writes to a PC COM2 will send data to the FMT1040's I/O processor board. The returns are sent by default to the keyboard buffer. An asterisk (*) marks the FACTORY DEFAULT. Except as marked (†), all commands have corresponding “SET” or “RETURN” commands. For detailed information about these commands, please refer to the FMT1000 Series Programmer's Guide. COMMAND

DESCRIPTION

R1D

RETURN USER KEY 1 DOWN (FACTORY DEFAULT = UDK1 DOWN SCANCODES)

R1M

RETURN RESPONSE STRING FOR COUNTER #1 MATCH

R1U

RETURN USER KEY 1 UP (FACTORY DEFAULT = UDK1 UP SCANCODES)

R25

RETURN INTERLEAVE 2 OF 5 MODE

R28

RETURN 128 MODE

R2D

RETURN USER KEY 2 DOWN (FACTORY DEFAULT = UDK2 DOWN SCANCODES)

R2M

RETURN RESPONSE STRING FOR COUNTER #1 MATCH

B-1

Page 56

FMT1040 Installation Guide

R2U

RETURN USER KEY 2 UP (FACTORY DEFAULT = UDK2 UP SCANCODES)

R39

RETURN CODE 3 OF 9 MODE

R3D

RETURN USER KEY 3 DOWN (FACTORY DEFAULT = UDK3 DOWN SCANCODES)

R3U

RETURN USER KEY 3 UP (FACTORY DEFAULT = UDK3 UP SCANCODES)

R4D

RETURN USER KEY 4 DOWN (FACTORY DEFAULT = UDK4 DOWN SCANCODES)

R4U

RETURN USER KEY 4 UP (FACTORY DEFAULT = UDK4 UP SCANCODES)

RAD

RETURN KEYBOARD AUTO DETECT FEATURE

RAE

RETURN AUX COMM PORT ENABLE

RAP

RETURN AUX RESPONSE PREFIX CHARACTERS (NO FACTORY DEFAULT)

RAS

RETURN AUX RESPONSE SUFFIX CHARACTERS (NO FACTORY DEFAULT)

RAT

RETURN AUX COMM TAG STRING (NO FACTORY DEFAULT)

RBA

RETURN BAUD AUX COMM

RBE

RETURN BATTERY SENSE ENABLE

RBH

RETURN BAUD HOST COMM

RBL

RETURN BACKLIGHT MODE

RBS

RETURN ON BATTERY RESPONSE STRING

RCB

RETURN CODABAR MODE

B-2

Page 57

I/O Processor Command Quick Reference

RCD

RETURN KEYBOARD INTERCHARACTER DELAY (FACTORY DEFAULT = 2 -> 20 MILLISECONDS)

RDA

RETURN DATA BITS/PARITY AUX COMM

RDE

RETURN DIGITAL I/O ENABLE

RDH

RETURN DATA BITS/PARITY HOST COMM

RDP

RETURN DIGITAL I/O PREFIX CHARACTERS (NO FACTORY DEFAULT)

RDS

RETURN DIGITAL I/O SUFFIX CHARACTERS (NO FACTORY DEFAULT)

RDT

RETURN DIGITAL I/O TAG STRING (NO FACTORY DEFAULT)

RE1

READ COUNTER 1

RE2

READ COUNTER 2

REA

RETURN AUTOENTER MODE AUX

RED

RETURN AUTOENTER MODE DIGITAL I/O

REI

RETURN AUTOENTER MODE INTERNAL

REP

RETURN AUTOCENTER MODE PERIPHERAL

RER†

RETURN ERROR CODE 0 = NO_ERROR 1 = COMMAND_ERROR 2 = PARAMETER_ERROR 3 = TIMEOUT_ERROR 4 = STOP_REQUEST_ERROR 5 = BUSY_ERROR

RES†

ECHO STRING INTERNAL PATH SETTING B-3

Page 58

FMT1040 Installation Guide

RHA

RETURN HANDSHAKE AUX COMM

RHH

RETURN HANDSHAKE HOST COMM

RI1

RETURN INPUT 1 RESPONSE STRING (NO FACTORY DEFAULT)

RI2

RETURN INPUT 2 RESPONSE STRING (NO FACTORY DEFAULT)

RIB

RETURN AUX COMM INPUT BEEP ENABLE

RIM

RETURN AUX COMM INPUT STRING MAXLEN (NO FACTORY DEFAULT)

RIN†

RETURN AUX COMM INPUT STATUS 0 = NO_ERROR 1 = COMMAND_ERROR 2 = PARAMETER_ERROR 3 = TIMEOUT_ERROR 4 = STOP_REQUEST_ERROR 5 = BUSY_ERROR

RIO

RETURN AUX COMM INPUT TIMEOUT (FACTORY DEFAULT = 0)

RIP

RETURN INTERNAL PREFIX CHARACTERS (NO FACTORY DEFAULT)

RIR

RETURN AUX COMM INPUT READ MODE (NO FACTORY DEFAULT)

RIS

RETURN INTERNAL SUFFIX CHARACTERS (NO FACTORY DEFAULT)

RIT

RETURN INTERNAL TAG STRING (NO FACTORY DEFAULT)

RKC

RETURN KEYBOARD CLICK

B-4

Page 59

I/O Processor Command Quick Reference

RKE

RETURN KEYBOARD ENABLE

RKH

RETURN KEYBOARD HARDWARE RESET ENABLE

RKR

RETURN KEYBOARD REPEAT

RKT

RETURN KEYBOARD TYPE

RM1

RETURN MATCH VALUE FOR COUNTER #1

RM2

RETURN MATCH VALUE FOR COUNTER #2

ROB†

RETURN ON-BATTERY STATE 0=NOT ON BATTERY 1=ON BATTERY

ROO

RETURN AUX COMM OUTPUT WRITE TIMEOUT (FACTORY DEFAULT = 0)

ROU†

RETURN AUX COMM OUTPUT WRITE STATUS 0 = NO_ERROR 1 = COMMAND_ERROR 2 = PARAMETER_ERROR 3 = TIMEOUT_ERROR 4 = STOP_REQUEST_ERROR 5 = BUSY_ERROR

RP5

RETURN PERIPHERAL TAG FOR 5-PIN CONNECTOR

RP9

RETURN PERIPHERAL TAG FOR 9-PIN CONNECTOR

RPA

RETURN HOST/AUX COMM PASSTHRU MODE (NO FACTORY DEFAULT)

RPE

RETURN PERIPHERAL PORT ENABLE

RPI

RETURN PREFIX INPUT AUX COMM (NO FACTORY DEFAULT) B-5

Page 60

FMT1040 Installation Guide

RPO

RETURN PREFIX OUTPUT AUX COMM (NO FACTORY DEFAULT)

RPP

RETURN PERIPHERAL PREFIX CHARACTERS (NO FACTORY DEFAULT)

RPS

RETURN PERIPHERAL SUFFIX CHARACTERS (NO FACTORY DEFAULT)

RPT

RETURN PERIPHERAL TAG STRING (NO FACTORY DEFAULT)

RR1

READ AND RESET COUNTER 1

RR2

READ AND RESET COUNTER 2

RRA

RETURN RESPONSE PATH FOR AUX COMM PORT

RRD

RETURN RESPONSE PATH FOR DIGITAL I/O

RRI

RETURN RESPONSE PATH FOR INTERNAL CMMDS

RRP

RETURN RESPONSE PATH FOR PERIPHERAL PORT

RS1

RETURN STATE INPUT 1 (0,1)

RS2

RETURN STATE INPUT 2 (0,1)

RSA

RETURN STOP BITS AUX COMM

RSB

RETURN SYMBOLOGY READ BEEP ENABLE

RSH

RETURN STOP BITS HOST COMM

RSI

RETURN SUFFIX INPUT AUX COMM (NO FACTORY DEFAULT)

RSM

RETURN SYMBOLOGY READ STRING MATCH LENGTH (FACTORY DEFAULT = 0 -> NO LENGTH IS PERFORMED)

RSO

RETURN SUFFIX OUTPUT AUX COMM

B-6

Page 61

I/O Processor Command Quick Reference

RSS

RETURN STARTUP STRING (FACTORY DEFAULT IS NULL)

RT1

RETURN MOMENTARY TIMEOUT FOR OUTPUT 1

RT2

RETURN MOMENTARY TIMEOUT FOR OUTPUT 2

RTC

RETURN PASSTHRU TERMINATION CHARACTERS (FACTORY DEFAULT = '+++')

RUP

RETURN UPC MODE

RVA

RETURN VIEWING ANGLE (FACTORY DEFAULT ARE AS FOLLOWS: FMT1020 QWERTY = 30 FMT1020 ALPHANUMERIC ABC = 30 FMT1020 NUMERIC = 30 FMT1060 = 30 FMT1040 = 50 THESE VALUES ARE SET AS A RESULT OF ISSUING A SKT COMMAND)

RVR†

RETURN FIRMWARE VERSION

S1D

SET USER KEY 1 DOWN

S1M

SET RESPONSE STRING FOR COUNTER #1 MATCH NO DEFAULT, DEFINABLE UP TO 80 CHARACTERS

S1U

SET USER KEY 1 UP

S25

SET INTERLEAVE 2 OF 5 MODE 0 = OFF 1 = ON*

S28

SET CODE 128 MODE

B-7

Page 62

FMT1040 Installation Guide

0 = OFF 1 = ON* S2D

SET USER KEY 2 DOWN

S2M

SET RESPONSE STRING FOR COUNTER #2 MATCH NO DEFAULT, DEFINABLE UP TO 80 CHARACTERS

S2U

SET USER KEY 2 UP

S39

SET CODE 3 OF 9 MODE 0 = OFF 1 = CODE 3 OF 9* 2 = CODE 2 OF 9 MOD 43 3 = FULL ASCII CODE 3 OF 9

S3D

SET USER KEY 3 DOWN

S3U

SET USER KEY 3 UP

S4D

SET USER KEY 4 DOWN

S4U

SET USER KEY 4 UP

SAD

SET KEYBOARD AUTO DETECT FEATURE 0=DISABLED 1=ENABLED *

SAE

SET AUX COMM PORT ENABLE 0 = OFF 1 = ON*

SAP

SET AUX RESPONSE PREFIX CHARACTERS

SAS

SET AUX RESPONSE SUFFIX CHARACTERS

SAT

SET AUX COMM TAG STRING

B-8