Symbol DS6708 Digital Scanner Product Reference Guide: Standard Default Parameters

Pages 403 to 412 of 458, from Symbol DS6708 Digital Scanner Product Reference Guide

The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol DS-6708

Page 403

Appendix A Standard Default Parameters

Table A-1

Standard Default Parameters Table Parameter

Parameter Number

Default

Page Number

User Preferences Set Default Parameter

Restore Defaults

4-4

Parameter Scanning

ECh

Enable

4-5

Beeper Tone

91h

Medium

4-6

Beeper Volume

8Ch

High

4-6

Power Mode

80h

Continuous On

4-7

Time Delay to Low Power Mode

92h

1 Minute

4-8

Trigger Mode

8Ah

Auto Aim

4-9

Picklist Mode

F0h 92h

Disabled Always

4-10

Presentation Mode

F1h, 74h

3 Sec

4-11

Decode Session Timeout

88h

9.9 Sec

4-13

Timeout Between Decodes, Same Symbol

89h

0.6 Sec

4-13

Beep After Good Decode

38h

Enable

4-14

Fuzzy 1D Processing

F1h, 02h

Enable

4-14

Decode Mirror Images

F1h, 19h

Never

4-15

1

User selection is required to configure this interface and this is the most common selection.

Page 404

A-2

Symbol DS6708 Digital Scanner Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Miscellaneous Scanner Options Transmit Code ID Character

2Dh

None

4-16

Prefix Value

63h, 69h

7013 <CR><LF>

4-17

Suffix 1 Value Suffix 2 Value

62h, 68h 64h, 6Ah

7013 <CR><LF>

4-17

Scan Data Transmission Format

EBh

Data as is

4-18

FN1 Substitution Values

67h, 6Dh

Set

4-19

Transmit “No Read” Message

5Eh

Disable

4-20

Synapse Interface

F0h, ACh

Standard Synapse Connection

4-21

Decoding Illumination

F0h 2Ah

Enable

5-3

Illumination Bank Control

F1h 3Bh

Full Illumination

5-4

Decode Aiming Pattern

F0h 32h

Enable

5-5

Low Light Enhancement

F1h 64h

Disable

5-5

Presentation Mode Field of View

F1h 61h

Default (Reduced)

5-6

USB Device Type

HID Keyboard Emulation

6-5

USB Country Keyboard Types (Country Codes)

North American

6-6

USB Keystroke Delay

No Delay

6-8

USB CAPS Lock Override

Disable

6-8

USB Ignore Unknown Characters

Enable

6-9

Emulate Keypad

Disable

6-9

Emulate Keypad with Leading Zero

Disable

6-10

USB Keyboard FN1 Substitution

Disable

6-10

Function Key Mapping

Disable

6-11

Simulated Caps Lock

Disable

6-11

Convert Case

No Case Conversion

6-12

Decoding Preferences

USB Host Parameters

1

User selection is required to configure this interface and this is the most common selection.

Page 405

Standard Default Parameters

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

RS-232 Host Parameters RS-232 Host Types

Standard1

7-7

Baud Rate

9600

7-8

Parity Type

None

7-10

Stop Bit Select

1 Stop Bit

7-11

Data Bits

8-Bit

7-11

Check Receive Errors

Enable

7-12

Hardware Handshaking

None

7-12

Software Handshaking

None

7-14

Host Serial Response Time-out

2 Sec

7-16

RTS Line State

Low RTS

7-17

Beep on <BEL>

Disable

7-17

Intercharacter Delay

0 msec

7-18

Nixdorf Beep/LED Options

Normal Operation

7-19

Ignore Unknown Characters

Send Bar Code

7-19

Port Address

None Selected

8-4

Convert Unknown to Code 39

Disable

8-5

Wand Emulation Host Types

Symbol OmniLink Interface Controller1

9-5

Leading Margin

80 msec

9-6

Polarity

Bar High/Margin Low

9-7

Ignore Unknown Characters

Ignore

9-7

Convert All Bar Codes to Code 39

Disable

9-8

Convert Code 39 to Full ASCII

Disable

9-9

IBM 468X/469X Host Parameters

Wand Emulation Host Parameters

1

User selection is required to configure this interface and this is the most common selection.

A-3

Page 406

A-4

Symbol DS6708 Digital Scanner Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Keyboard Wedge Host Parameters Keyboard Wedge Host Type

IBM PC/AT& IBM PC Compatibles1

10-5

Country Types (Country Codes)

North American

10-6

Ignore Unknown Characters

Transmit

10-8

Keystroke Delay

No Delay

10-8

Intra-Keystroke Delay

Disable

10-9

Alternate Numeric Keypad Emulation

Disable

10-9

Caps Lock On

Disable

10-10

Caps Lock Override

Disable

10-10

Convert Wedge Data

No Convert

10-11

Function Key Mapping

Disable

10-11

FN1 Substitution

Disable

10-12

Send and Make Break

Send

10-12

Beep Style

Beep on Successful Transmit

11-5

Parameter Pass-Through

Parameter Process and Pass Through

11-6

Convert Newer Code Types

Convert Newer Code Types

11-7

Module Width

20 µs

11-7

Convert All Bar Codes to Code 39

Do Not Convert to Code 39

11-8

Code 39 Full ASCII Conversion

Disable

11-8

Transmission Timeout

3 seconds

11-9

Ignore Unknown Characters

Ignore Unknown Characters

11-10

Leading Margin

2 ms

11-10

Check for Decode LED

Check for Decode LED

11-11

None1

12-1

Undecoded Scanner Emulation

123Scan Configuration Tool 123Scan Configuration 1

User selection is required to configure this interface and this is the most common selection.

Page 407

Standard Default Parameters

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

UPC/EAN UPC-A

01h

Enable

13-7

UPC-E

02h

Enable

13-7

UPC-E1

0Ch

Disable

13-8

EAN-8/JAN 8

04h

Enable

13-8

EAN-13/JAN 13

03h

Enable

13-9

Bookland EAN

53h

Disable

13-9

Decode UPC/EAN/JAN Supplementals (2 and 5 digits)

10h

Ignore

13-10

User-Programmable Supplementals Supplemental 1: Supplemental 2:

F1h 43h F1h 44h

13-13

UPC/EAN/JAN Supplemental Redundancy

50h

10

13-13

Transmit UPC-A Check Digit

28h

Enable

13-14

Transmit UPC-E Check Digit

29h

Enable

13-14

Transmit UPC-E1 Check Digit

2Ah

Enable

13-15

UPC-A Preamble

22h

System Character

13-16

UPC-E Preamble

23h

System Character

13-17

UPC-E1 Preamble

24h

System Character

13-18

Convert UPC-E to A

25h

Disable

13-19

Convert UPC-E1 to A

26h

Disable

13-19

EAN-8/JAN-8 Extend

27h

Disable

13-20

Bookland ISBN Format

F1h 40h

ISBN-10

13-21

UCC Coupon Extended Code

55h

Disable

13-22

ISSN EAN

F1h 69h

Disable

13-22

Code 128

08h

Enable

13-23

Set Length(s) for Code 128

D1h D2h

Any Length

13-23

GS1-128 (formerly UCC/EAN-128)

0Eh

Enable

13-25

Code 128

1

User selection is required to configure this interface and this is the most common selection.

A-5

Page 408

A-6

Symbol DS6708 Digital Scanner Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

ISBT 128

54h

Enable

13-25

ISBT Concatenation

F1h 41h

Disable

13-26

Check ISBT Table

F1h 42h

Enable

13-27

ISBT Concatenation Redundancy

DFh

10

13-27

Code 39

00h

Enable

13-28

Trioptic Code 39

0Dh

Disable

13-28

Convert Code 39 to Code 32 (Italian Pharmacy Code)

56h

Disable

13-29

Code 32 Prefix

E7h

Disable

13-29

Set Length(s) for Code 39

12h 13h

2 to 55

13-30

Code 39 Check Digit Verification

30h

Disable

13-32

Transmit Code 39 Check Digit

2Bh

Disable

13-32

Code 39 Full ASCII Conversion

11h

Disable

13-33

Buffer Code 39

71h

Disable

13-33

Code 93

09h

Disable

13-36

Set Length(s) for Code 93

1Ah 1Bh

4 to 55

13-36

Code 11

0Ah

Disable

13-38

Set Lengths for Code 11

1Ch 1Dh

4 to 55

13-38

Code 11 Check Digit Verification

34h

Disable

13-40

Transmit Code 11 Check Digit(s)

2Fh

Disable

13-41

Interleaved 2 of 5 (ITF)

06h

Enable

13-41

Set Lengths for I 2 of 5

16h 17h

14

13-42

I 2 of 5 Check Digit Verification

31h

Disable

13-44

Transmit I 2 of 5 Check Digit

2Ch

Disable

13-44

Convert I 2 of 5 to EAN 13

52h

Disable

13-45

Code 39

Code 93

Code 11

Interleaved 2 of 5 (ITF)

1

User selection is required to configure this interface and this is the most common selection.

Page 409

Standard Default Parameters

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Discrete 2 of 5 (DTF) Discrete 2 of 5

05h

Disable

13-45

Set Length(s) for D 2 of 5

14h 15h

12

13-46

Codabar

07h

Disable

13-48

Set Lengths for Codabar

18h 19h

5 to 55

13-48

CLSI Editing

36h

Disable

13-50

NOTIS Editing

37h

Disable

13-50

MSI

0Bh

Disable

13-51

Set Length(s) for MSI

1Eh 1Fh

4 to 55

13-51

MSI Check Digits

32h

One

13-53

Transmit MSI Check Digit

2Eh

Disable

13-53

MSI Check Digit Algorithm

33h

Mod 10/Mod 10

13-54

F0h 98h

Disable

13-54

Matrix 2 of 5

F1h 6Ah

Disable

13-55

Matrix 2 of 5 Lengths

F1h 6Bh F1h 6Ch

1 Length - 14

13-56

Matrix 2 of 5 Redundancy

F1h 6Dh

Disable

13-57

Matrix 2 of 5 Check Digit

F1h 6Eh

Disable

13-57

Transmit Matrix 2 of 5 Check Digit

F1h 6Fh

Disable

13-58

Inverse 1D

F1h 4Ah

Regular

13-59

US Postnet

59h

Enable

13-60

US Planet

5Ah

Enable

13-60

Transmit US Postal Check Digit

5Fh

Enable

13-61

Codabar (NW - 7)

MSI

Chinese 2 of 5 Chinese 2 of 5 Matrix 2 of 5

Postal Codes

1User selection is required to configure this interface and this is the most common selection.

A-7

Page 410

A-8

Symbol DS6708 Digital Scanner Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

UK Postal

5Bh

Enable

13-61

Transmit UK Postal Check Digit

60h

Enable

13-62

Japan Postal

F0h 22h

Enable

13-62

Australian Postal

F0h 23h

Enable

13-63

Netherlands KIX Code

F0h 46h

Enable

13-63

USPS 4CB/One Code/Intelligent Mail

F1h 50h

Disable

13-64

UPU FICS Postal

F1h 63h

Disable

13-64

GS1 DataBar-14

F0h 52h

Enable

13-65

GS1 DataBar Limited

F0h 53h

Enable

13-65

GS1 DataBar Expanded

F0h 54h

Enable

13-66

Convert GS1 DataBar to UPC/EAN

F0h 8Dh

Disable

13-66

Composite CC-C

F0h 55h

Disable

13-67

Composite CC-A/B

F0h 56h

Disable

13-67

Composite TLC-39

F0h 73h

Disable

13-68

UPC Composite Mode

F0h 58h

Always Linked

13-68

Composite Beep Mode

F0h 8Eh

Beep As Each Code Type is Decoded

13-69

GS1-128 Emulation Mode for GS1 Composite Codes (formerly UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes)

F0h ABh

Disable

13-69

PDF417

0Fh

Enable

13-70

MicroPDF417

E3h

Disable

13-70

Code 128 Emulation

7Bh

Disable

13-71

Data Matrix

F0h 24h

Enable

13-72

Data Matrix Inverse

F1h 4Ch

Regular

13-72

Maxicode

F0h 26h

Enable

13-73

GS1 DataBar

Composite

2D Symbologies

1User selection is required to configure this interface and this is the most common selection.

Page 411

Standard Default Parameters

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

QR Code

F0h 25h

Enable

13-74

QR Inverse

F1h 4Bh

Regular

13-74

MicroQR

F1h 3Dh

Enable

13-75

Aztec

F1h 3Eh

Enable

13-75

Aztec Inverse

F1h 4Dh

Regular

13-76

Redundancy Level

4Eh

1

13-77

Security Level

4Dh

1

13-79

Intercharacter Gap Size

F0h 7Dh

Normal

13-80

Symbology-Specific Security Levels

Report Version

13-80

Macro PDF Flush Macro PDF Buffer

13-81

Abort Macro PDF Entry

13-81

Drivers License Parsing (DS6708-DL only) Driver’s License Parsing

No Driver’s License Parsing

14-2

1User selection is required to configure this interface and this is the most common selection.

A-9

Page 412

A - 10 Symbol DS6708 Digital Scanner Product Reference Guide