The text of a manual · part 49 of 55
Symbol DS6708 Digital Scanner Product Reference Guide: Standard Default Parameters
Pages 403 to 412 of 458, from Symbol DS6708 Digital Scanner Product Reference Guide
The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol DS-6708
Page 403
Appendix A Standard Default Parameters
Table A-1
Standard Default Parameters Table Parameter
Parameter Number
Default
Page Number
User Preferences Set Default Parameter
Restore Defaults
4-4
Parameter Scanning
ECh
Enable
4-5
Beeper Tone
91h
Medium
4-6
Beeper Volume
8Ch
High
4-6
Power Mode
80h
Continuous On
4-7
Time Delay to Low Power Mode
92h
1 Minute
4-8
Trigger Mode
8Ah
Auto Aim
4-9
Picklist Mode
F0h 92h
Disabled Always
4-10
Presentation Mode
F1h, 74h
3 Sec
4-11
Decode Session Timeout
88h
9.9 Sec
4-13
Timeout Between Decodes, Same Symbol
89h
0.6 Sec
4-13
Beep After Good Decode
38h
Enable
4-14
Fuzzy 1D Processing
F1h, 02h
Enable
4-14
Decode Mirror Images
F1h, 19h
Never
4-15
1
User selection is required to configure this interface and this is the most common selection.
Page 404
A-2
Symbol DS6708 Digital Scanner Product Reference Guide
Table A-1
Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
Miscellaneous Scanner Options Transmit Code ID Character
2Dh
None
4-16
Prefix Value
63h, 69h
7013 <CR><LF>
4-17
Suffix 1 Value Suffix 2 Value
62h, 68h 64h, 6Ah
7013 <CR><LF>
4-17
Scan Data Transmission Format
EBh
Data as is
4-18
FN1 Substitution Values
67h, 6Dh
Set
4-19
Transmit “No Read” Message
5Eh
Disable
4-20
Synapse Interface
F0h, ACh
Standard Synapse Connection
4-21
Decoding Illumination
F0h 2Ah
Enable
5-3
Illumination Bank Control
F1h 3Bh
Full Illumination
5-4
Decode Aiming Pattern
F0h 32h
Enable
5-5
Low Light Enhancement
F1h 64h
Disable
5-5
Presentation Mode Field of View
F1h 61h
Default (Reduced)
5-6
USB Device Type
HID Keyboard Emulation
6-5
USB Country Keyboard Types (Country Codes)
North American
6-6
USB Keystroke Delay
No Delay
6-8
USB CAPS Lock Override
Disable
6-8
USB Ignore Unknown Characters
Enable
6-9
Emulate Keypad
Disable
6-9
Emulate Keypad with Leading Zero
Disable
6-10
USB Keyboard FN1 Substitution
Disable
6-10
Function Key Mapping
Disable
6-11
Simulated Caps Lock
Disable
6-11
Convert Case
No Case Conversion
6-12
Decoding Preferences
USB Host Parameters
1
User selection is required to configure this interface and this is the most common selection.
Page 405
Standard Default Parameters
Table A-1
Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
RS-232 Host Parameters RS-232 Host Types
Standard1
7-7
Baud Rate
9600
7-8
Parity Type
None
7-10
Stop Bit Select
1 Stop Bit
7-11
Data Bits
8-Bit
7-11
Check Receive Errors
Enable
7-12
Hardware Handshaking
None
7-12
Software Handshaking
None
7-14
Host Serial Response Time-out
2 Sec
7-16
RTS Line State
Low RTS
7-17
Beep on <BEL>
Disable
7-17
Intercharacter Delay
0 msec
7-18
Nixdorf Beep/LED Options
Normal Operation
7-19
Ignore Unknown Characters
Send Bar Code
7-19
Port Address
None Selected
8-4
Convert Unknown to Code 39
Disable
8-5
Wand Emulation Host Types
Symbol OmniLink Interface Controller1
9-5
Leading Margin
80 msec
9-6
Polarity
Bar High/Margin Low
9-7
Ignore Unknown Characters
Ignore
9-7
Convert All Bar Codes to Code 39
Disable
9-8
Convert Code 39 to Full ASCII
Disable
9-9
IBM 468X/469X Host Parameters
Wand Emulation Host Parameters
1
User selection is required to configure this interface and this is the most common selection.
A-3
Page 406
A-4
Symbol DS6708 Digital Scanner Product Reference Guide
Table A-1
Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
Keyboard Wedge Host Parameters Keyboard Wedge Host Type
IBM PC/AT& IBM PC Compatibles1
10-5
Country Types (Country Codes)
North American
10-6
Ignore Unknown Characters
Transmit
10-8
Keystroke Delay
No Delay
10-8
Intra-Keystroke Delay
Disable
10-9
Alternate Numeric Keypad Emulation
Disable
10-9
Caps Lock On
Disable
10-10
Caps Lock Override
Disable
10-10
Convert Wedge Data
No Convert
10-11
Function Key Mapping
Disable
10-11
FN1 Substitution
Disable
10-12
Send and Make Break
Send
10-12
Beep Style
Beep on Successful Transmit
11-5
Parameter Pass-Through
Parameter Process and Pass Through
11-6
Convert Newer Code Types
Convert Newer Code Types
11-7
Module Width
20 µs
11-7
Convert All Bar Codes to Code 39
Do Not Convert to Code 39
11-8
Code 39 Full ASCII Conversion
Disable
11-8
Transmission Timeout
3 seconds
11-9
Ignore Unknown Characters
Ignore Unknown Characters
11-10
Leading Margin
2 ms
11-10
Check for Decode LED
Check for Decode LED
11-11
None1
12-1
Undecoded Scanner Emulation
123Scan Configuration Tool 123Scan Configuration 1
User selection is required to configure this interface and this is the most common selection.
Page 407
Standard Default Parameters
Table A-1
Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
UPC/EAN UPC-A
01h
Enable
13-7
UPC-E
02h
Enable
13-7
UPC-E1
0Ch
Disable
13-8
EAN-8/JAN 8
04h
Enable
13-8
EAN-13/JAN 13
03h
Enable
13-9
Bookland EAN
53h
Disable
13-9
Decode UPC/EAN/JAN Supplementals (2 and 5 digits)
10h
Ignore
13-10
User-Programmable Supplementals Supplemental 1: Supplemental 2:
F1h 43h F1h 44h
13-13
UPC/EAN/JAN Supplemental Redundancy
50h
10
13-13
Transmit UPC-A Check Digit
28h
Enable
13-14
Transmit UPC-E Check Digit
29h
Enable
13-14
Transmit UPC-E1 Check Digit
2Ah
Enable
13-15
UPC-A Preamble
22h
System Character
13-16
UPC-E Preamble
23h
System Character
13-17
UPC-E1 Preamble
24h
System Character
13-18
Convert UPC-E to A
25h
Disable
13-19
Convert UPC-E1 to A
26h
Disable
13-19
EAN-8/JAN-8 Extend
27h
Disable
13-20
Bookland ISBN Format
F1h 40h
ISBN-10
13-21
UCC Coupon Extended Code
55h
Disable
13-22
ISSN EAN
F1h 69h
Disable
13-22
Code 128
08h
Enable
13-23
Set Length(s) for Code 128
D1h D2h
Any Length
13-23
GS1-128 (formerly UCC/EAN-128)
0Eh
Enable
13-25
Code 128
1
User selection is required to configure this interface and this is the most common selection.
A-5
Page 408
A-6
Symbol DS6708 Digital Scanner Product Reference Guide
Table A-1
Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
ISBT 128
54h
Enable
13-25
ISBT Concatenation
F1h 41h
Disable
13-26
Check ISBT Table
F1h 42h
Enable
13-27
ISBT Concatenation Redundancy
DFh
10
13-27
Code 39
00h
Enable
13-28
Trioptic Code 39
0Dh
Disable
13-28
Convert Code 39 to Code 32 (Italian Pharmacy Code)
56h
Disable
13-29
Code 32 Prefix
E7h
Disable
13-29
Set Length(s) for Code 39
12h 13h
2 to 55
13-30
Code 39 Check Digit Verification
30h
Disable
13-32
Transmit Code 39 Check Digit
2Bh
Disable
13-32
Code 39 Full ASCII Conversion
11h
Disable
13-33
Buffer Code 39
71h
Disable
13-33
Code 93
09h
Disable
13-36
Set Length(s) for Code 93
1Ah 1Bh
4 to 55
13-36
Code 11
0Ah
Disable
13-38
Set Lengths for Code 11
1Ch 1Dh
4 to 55
13-38
Code 11 Check Digit Verification
34h
Disable
13-40
Transmit Code 11 Check Digit(s)
2Fh
Disable
13-41
Interleaved 2 of 5 (ITF)
06h
Enable
13-41
Set Lengths for I 2 of 5
16h 17h
14
13-42
I 2 of 5 Check Digit Verification
31h
Disable
13-44
Transmit I 2 of 5 Check Digit
2Ch
Disable
13-44
Convert I 2 of 5 to EAN 13
52h
Disable
13-45
Code 39
Code 93
Code 11
Interleaved 2 of 5 (ITF)
1
User selection is required to configure this interface and this is the most common selection.
Page 409
Standard Default Parameters
Table A-1
Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
Discrete 2 of 5 (DTF) Discrete 2 of 5
05h
Disable
13-45
Set Length(s) for D 2 of 5
14h 15h
12
13-46
Codabar
07h
Disable
13-48
Set Lengths for Codabar
18h 19h
5 to 55
13-48
CLSI Editing
36h
Disable
13-50
NOTIS Editing
37h
Disable
13-50
MSI
0Bh
Disable
13-51
Set Length(s) for MSI
1Eh 1Fh
4 to 55
13-51
MSI Check Digits
32h
One
13-53
Transmit MSI Check Digit
2Eh
Disable
13-53
MSI Check Digit Algorithm
33h
Mod 10/Mod 10
13-54
F0h 98h
Disable
13-54
Matrix 2 of 5
F1h 6Ah
Disable
13-55
Matrix 2 of 5 Lengths
F1h 6Bh F1h 6Ch
1 Length - 14
13-56
Matrix 2 of 5 Redundancy
F1h 6Dh
Disable
13-57
Matrix 2 of 5 Check Digit
F1h 6Eh
Disable
13-57
Transmit Matrix 2 of 5 Check Digit
F1h 6Fh
Disable
13-58
Inverse 1D
F1h 4Ah
Regular
13-59
US Postnet
59h
Enable
13-60
US Planet
5Ah
Enable
13-60
Transmit US Postal Check Digit
5Fh
Enable
13-61
Codabar (NW - 7)
MSI
Chinese 2 of 5 Chinese 2 of 5 Matrix 2 of 5
Postal Codes
1User selection is required to configure this interface and this is the most common selection.
A-7
Page 410
A-8
Symbol DS6708 Digital Scanner Product Reference Guide
Table A-1
Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
UK Postal
5Bh
Enable
13-61
Transmit UK Postal Check Digit
60h
Enable
13-62
Japan Postal
F0h 22h
Enable
13-62
Australian Postal
F0h 23h
Enable
13-63
Netherlands KIX Code
F0h 46h
Enable
13-63
USPS 4CB/One Code/Intelligent Mail
F1h 50h
Disable
13-64
UPU FICS Postal
F1h 63h
Disable
13-64
GS1 DataBar-14
F0h 52h
Enable
13-65
GS1 DataBar Limited
F0h 53h
Enable
13-65
GS1 DataBar Expanded
F0h 54h
Enable
13-66
Convert GS1 DataBar to UPC/EAN
F0h 8Dh
Disable
13-66
Composite CC-C
F0h 55h
Disable
13-67
Composite CC-A/B
F0h 56h
Disable
13-67
Composite TLC-39
F0h 73h
Disable
13-68
UPC Composite Mode
F0h 58h
Always Linked
13-68
Composite Beep Mode
F0h 8Eh
Beep As Each Code Type is Decoded
13-69
GS1-128 Emulation Mode for GS1 Composite Codes (formerly UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes)
F0h ABh
Disable
13-69
PDF417
0Fh
Enable
13-70
MicroPDF417
E3h
Disable
13-70
Code 128 Emulation
7Bh
Disable
13-71
Data Matrix
F0h 24h
Enable
13-72
Data Matrix Inverse
F1h 4Ch
Regular
13-72
Maxicode
F0h 26h
Enable
13-73
GS1 DataBar
Composite
2D Symbologies
1User selection is required to configure this interface and this is the most common selection.
Page 411
Standard Default Parameters
Table A-1
Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
QR Code
F0h 25h
Enable
13-74
QR Inverse
F1h 4Bh
Regular
13-74
MicroQR
F1h 3Dh
Enable
13-75
Aztec
F1h 3Eh
Enable
13-75
Aztec Inverse
F1h 4Dh
Regular
13-76
Redundancy Level
4Eh
1
13-77
Security Level
4Dh
1
13-79
Intercharacter Gap Size
F0h 7Dh
Normal
13-80
Symbology-Specific Security Levels
Report Version
13-80
Macro PDF Flush Macro PDF Buffer
13-81
Abort Macro PDF Entry
13-81
Drivers License Parsing (DS6708-DL only) Driver’s License Parsing
No Driver’s License Parsing
14-2
1User selection is required to configure this interface and this is the most common selection.
A-9
Page 412
A - 10 Symbol DS6708 Digital Scanner Product Reference Guide