Page 245

Symbologies 13 - 69

Composite Beep Mode Parameter # F0h, 8Eh To select the number of decode beeps when a composite bar code is decoded, scan the appropriate bar code.

Single Beep after both are decoded (00h)

*Beep as each code type is decoded (01h)

Double Beep after both are decoded (02h)

GS1-128 Emulation Mode for GS1 Composite Codes (formerly UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes) Parameter # F0h, ABh Select whether to enable or disable this mode.

Enable GS1-128 Emulation Mode for GS1 Composite Codes (01h)

*Disable GS1-128 Emulation Mode for GS1 Composite Codes (00h)

Page 246

13 - 70 Symbol DS6708 Digital Scanner Product Reference Guide

2D Symbologies Enable/Disable PDF417 Parameter # 0Fh To enable or disable PDF417, scan the appropriate bar code below.

*Enable PDF417 (01h)

Disable PDF417 (00h)

Enable/Disable MicroPDF417 Parameter # E3h To enable or disable MicroPDF417, scan the appropriate bar code below.

Enable MicroPDF417 (01h)

*Disable MicroPDF417 (00h)

Page 247

Symbologies 13 - 71

Code 128 Emulation Parameter # 7Bh Enable this parameter to transmit data from certain MicroPDF417 symbols as Code 128. AIM Code ID Character (01h) on page 4-16 must be enabled for this parameter to work. Enable Code 128 Emulation to transmit these MicroPDF417 symbols with one of the following prefixes: ]C1 if the first codeword is 903-905

]C2 if the first codeword is 908 or 909

]C0 if the first codeword is 910 or 911

Disable Code 128 Emulation to transmit these MicroPDF417 symbols with one of the following prefixes: ]L3 if the first codeword is 903-905

]L4 if the first codeword is 908 or 909

]L5 if the first codeword is 910 or 911

Scan a bar code below to enable or disable Code 128 Emulation. NOTE

Linked MicroPDF codewords 906, 907, 912, 914, and 915 are not supported. Use GS1 Composites instead.

Enable Code 128 Emulation (01h)

*Disable Code 128 Emulation (00h)

Page 248

13 - 72 Symbol DS6708 Digital Scanner Product Reference Guide

Data Matrix Parameter # F0h, 24h To enable or disable Data Matrix, scan the appropriate bar code below.

*Enable Data Matrix (01h)

Disable Data Matrix (00h)

Data Matrix Inverse Parameter # F1h 4Ch This parameter sets the Data Matrix inverse decoder setting. Options are:

• Regular Only - the scanner decodes regular Data Matrix bar codes only. • Inverse Only - the scanner decodes inverse Data Matrix bar codes only. • Inverse Autodetect - the scanner decodes both regular and inverse Data Matrix bar codes.

*Regular (00h)

Inverse Only (01h)

Inverse Autodetect (02h)

Page 249

Symbologies 13 - 73

Maxicode Parameter # F0h, 26h To enable or disable Maxicode, scan the appropriate bar code below.

*Enable Maxicode (01h)

Disable Maxicode (00h)

Page 250

13 - 74 Symbol DS6708 Digital Scanner Product Reference Guide

QR Code Parameter # F0h,25h To enable or disable QR Code, scan the appropriate bar code below.

*Enable QR Code (01h)

Disable QR Code (00h)

QR Inverse Parameter # F1h 4Bh This parameter sets the QR inverse decoder setting. Options are:

• Regular Only - the scanner decodes regular QR bar codes only. • Inverse Only - the scanner decodes inverse QR bar codes only. • Inverse Autodetect - the scanner decodes both regular and inverse QR bar codes.

*Regular (00h)

Inverse Only (01h)

Inverse Autodetect (02h)

Page 251

Symbologies 13 - 75

MicroQR Parameter # F1h 3Dh To enable or disable MicroQR, scan the appropriate bar code below.

*Enable MicroQR (01h)

Disable MicroQR (00h)

Aztec Parameter # F1h 3Eh To enable or disable Aztec, scan the appropriate bar code below.

*Enable Aztec (01h)

Disable Aztec (00h)

Page 252

13 - 76 Symbol DS6708 Digital Scanner Product Reference Guide

Aztec Inverse Parameter # F1h 4Dh This parameter sets the Aztec inverse decoder setting. Options are:

• Regular Only - the scanner decodes regular Aztec bar codes only. • Inverse Only - the scanner decodes inverse Aztec bar codes only. • Inverse Autodetect - the scanner decodes both regular and inverse Aztec bar codes.

*Regular (00h)

Inverse Only (01h)

Inverse Autodetect (02h)

Page 253

Symbologies 13 - 77

Redundancy Level Parameter # 4Eh The digital scanner offers four levels of decode redundancy. Select higher redundancy levels for decreasing levels of bar code quality. As redundancy levels increase, the digital scanner’s aggressiveness decreases. Select the redundancy level appropriate for the bar code quality.

Redundancy Level 1 The following code types must be successfully read twice before being decoded: Table 13-2 Redundancy Level 1 Codes

Code Type

Code Length

Codabar

8 characters or less

MSI

4 characters or less

D 2 of 5

8 characters or less

I 2 of 5

8 characters or less

Redundancy Level 2 The following code types must be successfully read twice before being decoded: Table 13-3 Redundancy Level 2 Codes

Code Type All

Code Length All

Redundancy Level 3 Code types other than the following must be successfully read twice before being decoded. The following codes must be read three times: Table 13-4 Redundancy Level 3 Codes

Code Type

Code Length

MSI Plessey

4 characters or less

D 2 of 5

8 characters or less

I 2 of 5

8 characters or less

Codabar

8 characters or less

Page 254

13 - 78 Symbol DS6708 Digital Scanner Product Reference Guide

Redundancy Level 4 The following code types must be successfully read three times before being decoded: Table 13-5 Redundancy Level 4 Codes

Code Type

Code Length

All

All

*Redundancy Level 1 (01h)

Redundancy Level 2 (02h)

Redundancy Level 3 (03h)

Redundancy Level 4 (04h)