Symbol DS6708 Digital Scanner Product Reference Guide: Scanner Emulation Interface

Pages 163 to 174 of 458, from Symbol DS6708 Digital Scanner Product Reference Guide

The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol DS-6708

Page 163

Chapter 11 Scanner Emulation Interface Introduction This chapter describes how to set up the digital scanner with a Scanner Emulation host. In this mode, the digital scanner connects to an external decoder or to a decoder integrated in a mobile computer or Point-of-Sale (POS) terminal. Throughout the programming bar code menus, asterisks (*) indicate default values.

* Indicates Default

*Parameter Process

Feature/Option and Pass-Through

NOTE

Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces do not merge.

Page 164

11 - 2 Symbol DS6708 Digital Scanner Product Reference Guide

Connecting Using Scanner Emulation To perform Scanner Emulation, connect the digital scanner to a mobile computer, or a controller which collects the data and interprets it for the host. Host Port Connector

Interface Cable

Figure 11-1 Scanner Emulation Connection

Host Port Connector

Interface Cable

Figure 11-2 Scanner Emulation Connection for Scanner with Base NOTE

Interface cables vary depending on configuration. The connectors illustrated in Figure 11-1 and Figure 11-2 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner are the same.

1.

Attach the modular connector of the Scanner Emulation interface cable to the cable interface port on the digital scanner. See Installing the Interface Cable on page 1-3.

2.

Connect the other end of the Scanner Emulation interface cable to the scanner port on the mobile computer or controller.

Page 165

Scanner Emulation Interface 11 - 3

3.

Scan the Scanner Emulation Host bar code from Scanner Emulation Host on page 11-5 to enable the Scanner Emulation host interface.

4.

To modify any other parameter options, scan the appropriate bar codes in this chapter. WARNING!

Connect the digital scanner to 5 volt decoders only. Connecting the digital scanner to a 12 volt decoder can damage the digital scanner and invalidate the warranty.

Page 166

11 - 4 Symbol DS6708 Digital Scanner Product Reference Guide

Scanner Emulation Parameter Defaults Table 11-1 lists the defaults for the Scanner Emulation host. To change any option, scan the appropriate bar code(s) provided in the Scanner Emulation Host Parameters section beginning on page 11-5. NOTE

See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.

Table 11-1 Scanner Emulation Default Table

Parameter

Default

Page Number

Beep Style

Beep on Successful Transmit

11-5

Parameter Pass-Through

Parameter Process and Pass Through

11-6

Convert Newer Code Types

Convert Newer Code Types

11-7

Module Width

20 µs

11-7

Convert All Bar Codes to Code 39

Do Not Convert to Bar Codes to Code 39

11-8

Code 39 Full ASCII Conversion

Disable

11-8

Transmission Timeout

3 seconds

11-9

Ignore Unknown Characters

Ignore Unknown Characters

11-10

Leading Margin

2 ms

11-10

Check for Decode LED

Check for Decode LED

11-11

Page 167

Scanner Emulation Interface 11 - 5

Scanner Emulation Host Scan the bar code below to enable the Scanner Emulation host.

Scanner Emulation Host

Scanner Emulation Host Parameters Beep Style The Scanner Emulation host supports three beep styles.

• Beep On Successful Transmit: The digital scanner beeps when the attached decoder issues the decode signal to the digital scanner, so the digital scanner and the attached decoder beep at the same time.

• Beep At Decode Time: The digital scanner beeps upon decode. This results in a double beep sequence from most decoders, since the digital scanner beeps, and the decoder beeps (at a different frequency) when it successfully decodes the output.

• Do Not Beep: Only the attached decoder issues the decode beep. In all cases, if an error occurs, the digital scanner issues error beeps.

*Beep On Successful Transmit

Beep At Decode Time

Do Not Beep

Page 168

11 - 6 Symbol DS6708 Digital Scanner Product Reference Guide

Parameter Pass-Through The Scanner Emulation host can process parameter bar code messages and send them to the attached decoder. In this way, customers using Symbol compliant decoders can control the behavior of the entire system by scanning the necessary parameters only once. For example, to enable D 2 of 5, scan the D 2 of 5 Enable parameter bar code. The digital scanner and the attached decoder both process the parameter.

*Parameter Process and Pass-Through

Parameter Process Only

Page 169

Scanner Emulation Interface 11 - 7

Convert Newer Code Types The digital scanner supports a variety of code types that are not decodable by attached decoder systems. To allow compatibility in these environments, the digital scanner converts these code types to more commonly decodable symbologies, as per the following chart. Symbologies not listed on this chart transmit normally. Scan this Code Type:

Transmitted as:

Code 11

Code 39

GS1 DataBar (14, Limited, and Expanded), Coupon Code, PDF, MicroPDF, MaxiCode, Data Matrix, QR Code, Postal Codes, Composite Codes

Code 128

When decoding these code types with this parameter disabled, the digital scanner issues Convert Error beeps and transmits no data. The amount of data in the scanned newer bar code type should not exceed that of the conversion code type.

*Convert Newer Code Types

Reject Newer Code Types

Module Width The standard module width is 20 µs. For an extremely slow decoder system, select 50 µs Module Width.

*20 µs Module Width

50 µs Module Width

Page 170

11 - 8 Symbol DS6708 Digital Scanner Product Reference Guide

Convert All Bar Codes to Code 39 Scan a bar code below to enable or disable converting all bar code data to Code 39.

*Do Not Convert Bar Codes To Code 39

Convert All To Code 39

Code 39 Full ASCII Conversion By default, a space replaces any characters that do not have a corresponding character in the Code 39 symbology set. Enable this parameter to encode data sent to the Scanner Emulation host in Code 39 Full ASCII. The host must be able to interpret Code 39 Full ASCII data. This setting applies only if you enabled Convert to Code 39.

*Disable Convert Code 39 To Full ASCII

Enable Convert Code 39 To Full ASCII

NOTE

Scanner Emulation emits an error beep and does not send any data if the scanned data exceeds the maximum length for Code 39.

Page 171

Scanner Emulation Interface 11 - 9

Transmission Timeout The Scanner Emulation host transmits bar code data to the attached decoder and waits for the decoder to assert the Decode signal, indicating successful transmission. If, after a specified amount of time, the Decode signal is not asserted (indicating that the attached decoder did not successfully receive the bar code data), the digital scanner issues transmit error beeps. Scan the appropriate bar code below to select the desired transmission timeout.

*3 Second Transmission Timeout

4 Second Transmission Timeout

5 Second Transmission Timeout

10 Second Transmission Timeout

30 Second Transmission Timeout

Page 172

11 - 10 Symbol DS6708 Digital Scanner Product Reference Guide

Ignore Unknown Characters Unknown characters are characters the decoder does not recognize. Select Ignore Unknown Characters to send all bar code data except for unknown characters. The digital scanner issues no error beeps. Select Convert Error on Unknown Characters to prevent sending bar codes containing at least one unknown character to the decoder. The digital scanner issues a convert error beep.

*Ignore Unknown Characters

Convert Error On Unknown Characters

Leading Margin Scan a bar code below to select a leading margin duration.

1 ms Leading Margin

*2 ms Leading Margin

3 ms Leading Margin

Page 173

Scanner Emulation Interface 11 - 11

Leading Margin (continued)

5 ms Leading Margin

10 ms Leading Margin

Check For Decode LED The attached decoder normally asserts the Decode line to signal to the Scanner Emulation host to indicate that it successfully decoded the transmitted bar code. Some decoders, however, do not assert the Decode signal. In this case, the digital scanner emits transmit error beeps to indicate that the bar code did not successfully transmit. Scan the Ignore Decode LED bar code to disable the Transmit Error beeps.

*Check For Decode LED

Ignore Decode LED

Page 174