The text of a manual · part 21 of 55
Symbol DS6708 Digital Scanner Product Reference Guide: Keyboard Wedge Interface, pages 139 to 146
Pages 139 to 146 of 458, from Symbol DS6708 Digital Scanner Product Reference Guide
The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol DS-6708
Page 139
Chapter 10 Keyboard Wedge Interface Introduction This chapter describes how to set up a Keyboard Wedge interface with the digital scanner. With this interface, the digital scanner is connected between the keyboard and host computer, and translates bar code data into keystrokes. The host computer accepts the keystrokes as if they originated from the keyboard. This mode adds bar code reading functionality to a system designed for manual keyboard input. Keyboard keystrokes are simply passed through. Throughout the programming bar code menus, asterisks (*) indicate default values.
* Indicates Default
NOTE
*North American
Feature/Option
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces do not merge.
Page 140
10 - 2 Symbol DS6708 Digital Scanner Product Reference Guide
Connecting a Keyboard Wedge Interface Male DIN Connector
Keyboard Connector
Female DIN Connector
Figure 10-1 Keyboard Wedge Connection with Y-cable
Keyboard Connector
Female DIN Connector
Figure 10-2 Keyboard Wedge Connection with Y-cable for Scanner with Base
To connect the Keyboard Wedge interface Y-cable: NOTE
Interface cables vary depending on configuration. The connectors illustrated in Figure 10-1 and Figure 10-2 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner are the same
Page 141
Keyboard Wedge Interface 10 - 3
1.
Turn off the host and unplug the keyboard connector.
2.
Attach the modular connector of the Y-cable to the cable interface port on the digital scanner. See Installing the Interface Cable on page 1-3.
3.
Connect the round male DIN host connector of the Y-cable to the keyboard port on the host device.
4.
Connect the round female DIN keyboard connector of the Y-cable to the keyboard connector.
5.
If needed, attach the optional power supply to the connector in the middle of the Y-cable.
6.
Ensure that all connections are secure.
7.
Turn on the host system.
8.
Select the Keyboard Wedge host type by scanning the appropriate bar code from Keyboard Wedge Host Types on page 10-5.
9.
To modify any other parameter options, scan the appropriate bar codes in this chapter.
Keyboard Wedge Parameter Defaults Table 10-1 lists the defaults for Keyboard Wedge host parameters. To change any option, scan the appropriate bar code(s) in the Keyboard Wedge Host Parameters section beginning on page 10-5. NOTE
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Table 10-1 Keyboard Wedge Host Default Table
Parameter
Default
Page Number
Keyboard Wedge Host Parameters Keyboard Wedge Host Type
IBM PC/AT& IBM PC Compatibles
10-5
Country Types (Country Codes)
North American
10-6
Ignore Unknown Characters
Transmit
10-8
Keystroke Delay
No Delay
10-8
Intra-Keystroke Delay
Disable
10-9
Alternate Numeric Keypad Emulation
Disable
10-9
Caps Lock On
Disable
10-10
Caps Lock Override
Disable
10-10
Convert Wedge Data
No Convert
10-11
Page 142
10 - 4 Symbol DS6708 Digital Scanner Product Reference Guide
Table 10-1 Keyboard Wedge Host Default Table (Continued)
Parameter
Default
Page Number
Function Key Mapping
Disable
10-11
FN1 Substitution
Disable
10-12
Send and Make Break
Send
10-12
Page 143
Keyboard Wedge Interface 10 - 5
Keyboard Wedge Host Parameters Keyboard Wedge Host Types Select the Keyboard Wedge host by scanning one of the bar codes below.
IBM PC/AT & IBM PC Compatibles
IBM PS/2 (Model 30)
IBM AT Notebook
NCR 7052
Page 144
10 - 6 Symbol DS6708 Digital Scanner Product Reference Guide
Keyboard Wedge Country Types - Country Codes Scan the bar code corresponding to the keyboard type. If your keyboard type does not appear, see Alternate Numeric Keypad Emulation on page 10-9.
*North American
German Windows
French Windows
French Canadian Windows 95/98
French Canadian Windows XP/2000
Spanish Windows
Page 145
Keyboard Wedge Interface 10 - 7
Keyboard Wedge Country Types - Country Codes (continued)
Italian Windows
Swedish Windows
UK English Windows
Japanese Windows
Portuguese-Brazilian Windows
Page 146
10 - 8 Symbol DS6708 Digital Scanner Product Reference Guide
Ignore Unknown Characters Unknown characters are characters the host does not recognize. Select Send Bar Codes With Unknown Characters to send all bar code data except for unknown characters. The digital scanner issues no error beeps. Select Do Not Send Bar Codes With Unknown Characters to send bar code data up to the first unknown character. The digital scanner issues an error beep.
*Send Bar Codes with Unknown Characters (Transmit)
Do Not Send Bar Codes with Unknown Characters
Keystroke Delay This is the delay in milliseconds between emulated keystrokes. Scan a bar code below to increase the delay when hosts require a slower transmission of data.
*No Delay
Medium Delay (20 msec)
Long Delay (40 msec)