Page 69
Chapter 5 Decoding Preferences Introduction You can program the digital scanner to perform various functions, or activate different features. This chapter describes decoding preference features and provides programming bar codes for selecting these features. The digital scanner ships with the settings shown in the Decoding Preferences Parameter Defaults on page 5-2 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the digital scanner is powered down. NOTE
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces are not merging.
If not using a USB cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host. To return all features to default values, scan the Set Default Parameter on page 4-4. Throughout the programming bar code menus, asterisks (*) indicate default values.
* Indicates Default
*Enable Decode Aiming Pattern (02h)
Feature/Option
Page 70
5-2
Symbol DS6708 Digital Scanner Product Reference Guide
Scanning Sequence Examples In most cases scanning one bar code sets the parameter value. For example, to disable the decode aiming pattern, scan the Disable Decode Aiming Pattern bar code listed under Decode Aiming Pattern on page 5-5. The digital scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters require scanning several bar codes. See these parameter descriptions for this procedure.
Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Decoding Preferences Parameter Defaults Table 5-1 lists the defaults for decoding preferences parameters. There are two ways to change the default values:
• Scan the appropriate bar codes in this guide. These new values replace the standard default values in memory. To recall the default parameter values, scan the Set Default Parameter on page 4-4.
• Configure the digital scanner using the 123Scan configuration program (see Chapter 12, 123Scan). NOTE
Table 5-1
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Decoding Preferences Parameter Defaults Parameter
Parameter Number
Default
Page Number
Decoding Options Decoding Illumination
F0h 2Ah
Enable
5-3
Illumination Bank Control
F1h 3Bh
Full Illumination
5-4
Decode Aiming Pattern
F0h 32h
Enable
5-5
Low Light Enhancement
F1h 64h
Disable
5-5
Presentation Mode Field of View
F1h 61h
Default (Reduced)
5-6
Page 71
Decoding Preferences
5-3
Decoding Preferences The parameters in this chapter control bar code decoding characteristics.
Decoding Illumination Parameter # F0h, 2Ah Selecting Enable Decoding Illumination causes the digital scanner to flash illumination to aid decoding. Select Disable Decoding Illumination to prevent the digital scanner from using decoding illumination. Enabling illumination usually results in superior images. The effectiveness of the illumination decreases as the distance to the target increases.
*Enable Decoding Illumination (01h)
Disable Decoding Illumination (00h)
Page 72
5-4
Symbol DS6708 Digital Scanner Product Reference Guide
Illumination Bank Control Parameter # F1h 3Bh Select an illumination bank control parameter to control the illumination banks on the scan engine.
• Full
(0) (default): Enable the full illumination system.
• Auto (1): The illumination system automatically switches from left to right banks. • Left
(2): The left bank is enabled.
• Right (3): The right bank is enabled.
*Full Illumination (00h)
Auto Illumination (01h)
Left Illumination (02h)
Right Illumination (03h)
Page 73
Decoding Preferences
5-5
Decode Aiming Pattern Parameter # F0h, 32h This parameter only applies in Decode Mode. Select Enable Decode Aiming Pattern to project the aiming pattern during bar code capture, or Disable Decode Aiming Pattern to turn the aiming pattern off. NOTE
With Picklist Mode on page 4-10 enabled, the decode aiming pattern flashes even when the Decode Aiming Pattern is disabled.
*Enable Decode Aiming Pattern (02h)
Disable Decode Aiming Pattern (00h)
Low Light Enhancement Parameter # F1h, 64h In Scanstand mode, selecting Enable Low Light Enhancement causes illumination to remain on at a low level in low lighting conditions. Select Disable Low Light Enhancement to prevent illumination from remaining on under these conditions.
Enable Low Light Enhancement (01h)
*Disable Low Light Enhancement (00h)
Page 74
5-6
Symbol DS6708 Digital Scanner Product Reference Guide
Presentation Mode Field of View Parameter # F1h, 61h In presentation mode, the digital scanner searches for a bar code in a smaller region around the aiming pattern’s center cross to speed search time. To use a full field of view, scan Presentation Mode Full Field of View. This allows the digital scanner to search the larger area of the aiming pattern.
*Presentation Mode Default Field of View (01h)
Presentation Mode Full Field of View (02h)