Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 26 of 50

DS6608 Product Reference Guide: Symbologies, pages 185 to 194

Pages 185 to 194 of 402, from DS6608 Product Reference Guide

The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol DS-6608

Page 185

Symbologies 13-21

Enable/Disable UCC/EAN-128 Parameter # 0Eh To enable or disable UCC/EAN-128, scan the appropriate bar code below.

*Enable UCC/EAN-128 (01h)

Disable UCC/EAN-128 (00h)

Enable/Disable ISBT 128 Parameter # 54h ISBT 128 is a variant of Code 128 used in the blood bank industry. Scan a bar code below to enable or disable ISBT 128. If necessary, the host must perform concatenation of the ISBT data.

*Enable ISBT 128 (01h)

Disable ISBT 128 (00h)

Page 186

13-22 DS6608 Product Reference Guide

Code 39 Enable/Disable Code 39 Parameter # 00h To enable or disable Code 39, scan the appropriate bar code below.

*Enable Code 39 (01h)

Disable Code 39 (00h)

Enable/Disable Trioptic Code 39 Parameter # 0Dh Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges. Trioptic Code 39 symbols always contain six characters. To enable or disable Trioptic Code 39, scan the appropriate bar code below.

Enable Trioptic Code 39 (01h)

*Disable Trioptic Code 39 (00h)

Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.

Note

Page 187

Symbologies 13-23

Convert Code 39 to Code 32 Parameter # 56h Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32. Code 39 must be enabled for this parameter to function.

Note

Enable Convert Code 39 to Code 32 (01h)

*Disable Convert Code 39 to Code 32 (00h)

Code 32 Prefix Parameter # E7h Scan the appropriate bar code below to enable or disable adding the prefix character “A” to all Code 32 bar codes. Convert Code 39 to Code 32 must be enabled for this parameter to function.

Note

Enable Code 32 Prefix (01h)

*Disable Code 32 Prefix (00h)

Page 188

13-24 DS6608 Product Reference Guide

Set Lengths for Code 39 Parameter # L1 = 12h, L2 = 13h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 39 to any length, one or two discrete lengths, or lengths within a specific range. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options. When setting lengths for different bar code types by scanning single digit numbers, single digit numbers must always be preceded by a leading zero.

Note •

•

•

•

One Discrete Length - Select this option to decode only Code 39 symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 39 symbols with 14 characters, scan Code 39 - One Discrete Length, then scan 1 followed by 4. To correct an error or change the selection, scan Cancel on page D-4. Two Discrete Lengths - Select this option to decode only Code 39 symbols containing either of two selected lengths. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only those Code 39 symbols containing either 2 or 14 characters, select Code 39 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or change the selection, scan Cancel on page D-4. Length Within Range - Select this option to decode a Code 39 symbol with a specific length range. Select lengths using numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 - Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). To correct an error or change the selection, scan Cancel on page D-4. Any Length - Select this option to decode Code 39 symbols containing any number of characters within the digital scanner capability.

Code 39 - One Discrete Length

Code 39 - Two Discrete Lengths

Page 189

Symbologies 13-25

Set Lengths for Code 39 (continued)

Code 39 - Length Within Range

Code 39 - Any Length

Code 39 Check Digit Verification Parameter # 30h When this feature is enabled, the digital scanner checks the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm. Only Code 39 symbols which include a modulo 43 check digit are decoded. Enable this feature if the Code 39 symbols contain a Modulo 43 check digit.

Enable Code 39 Check Digit (01h)

*Disable Code 39 Check Digit (00h)

Page 190

13-26 DS6608 Product Reference Guide

Transmit Code 39 Check Digit Parameter # 2Bh Scan a bar code below to transmit Code 39 data with or without the check digit.

Transmit Code 39 Check Digit (Enable) (01h)

*Do Not Transmit Code 39 Check Digit (Disable) (00h)

Code 39 Check Digit Verification must be enabled for this parameter to function.

Note

Code 39 Full ASCII Conversion Parameter # 11h Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. To enable or disable Code 39 Full ASCII, scan the appropriate bar code below.

Enable Code 39 Full ASCII (01h)

*Disable Code 39 Full ASCII (00h)

Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.

Note

Code 39 Full ASCII to Full ASCII Correlation is host-dependent, and is therefore described in the ASCII Character Set Table for the appropriate interface. See the ASCII Character Set for Keyboard Wedge on page 6-15, the ASCII Character Set for USB on page 8-13, or the ASCII Character Set for RS-232 on page 7-21.

Page 191

Symbologies 13-27

Code 39 Buffering (Scan & Store) Parameter # 71h This feature allows the digital scanner to accumulate data from multiple Code 39 symbols. Selecting the Scan and Store option (Buffer Code 39) temporarily buffers all Code 39 symbols having a leading space as a first character for later transmission. The leading space is not buffered. Decode of a valid Code 39 symbol with no leading space causes transmission in sequence of all buffered data in a first-in first-out format, plus transmission of the “triggering” symbol. See the following pages for further details. When the Do Not Buffer Code 39 option is selected, all decoded Code 39 symbols are transmitted immediately without being stored in the buffer. This feature affects Code 39 only. If selecting Buffer Code 39, we recommend configuring the digital scanner to decode Code 39 symbology only.

Buffer Code 39 (Enable) (01h)

*Do Not Buffer Code 39 (Disable) (00h)

While there is data in the transmission buffer, selecting Do Not Buffer Code 39 is not allowed. The buffer holds 200 bytes of information. To disable Code 39 buffering when there is data in the transmission buffer, first force the buffer transmission (see Transmit Buffer on page 13-28) or clear the buffer.

Buffer Data To buffer data, Code 39 buffering must be enabled and a Code 39 symbol must be read with a space immediately following the start pattern. • • •

Unless the data overflows the transmission buffer, the digital scanner issues a lo/hi beep to indicate successful decode and buffering. (For overflow conditions, see Overfilling Transmission Buffer.) The digital scanner adds the decoded data excluding the leading space to the transmission buffer. No transmission occurs.

Page 192

13-28 DS6608 Product Reference Guide

Clear Transmission Buffer To clear the transmission buffer, scan the Clear Buffer bar code below, which contains only a start character, a dash (minus), and a stop character. • • •

The digital scanner issues a short hi/lo/hi beep. The digital scanner erases the transmission buffer. No transmission occurs.

Clear Buffer

The Clear Buffer contains only the dash (minus) character. In order to scan this command, be sure Code 39 length is set to include length 1.

Note Transmit Buffer There are two methods to transmit the Code 39 buffer. 1. Scan the Transmit Buffer bar code below. Only a start character, a plus (+), and a stop character. • The digital scanner transmits and clears the buffer. • The digital scanner issues a Lo/Hi beep.

Transmit Buffer

2. Scan a Code 39 bar code with a leading character other than a space. • The digital scanner appends new decode data to buffered data. • The digital scanner transmits and clears the buffer. • The digital scanner signals that the buffer was transmitted with a lo/hi beep. • Digital Scanner transmits and clears the buffer. The Transmit Buffer contains only a plus (+) character. In order to scan this command, be sure Code 39 length is set to include length 1.

Note

Page 193

Symbologies 13-29

Overfilling Transmission Buffer The Code 39 buffer holds 200 characters. If the symbol just read results in an overflow of the transmission buffer: • •

The digital scanner indicates that the symbol was rejected by issuing three long, high beeps. No transmission occurs. The data in the buffer is not affected.

Attempt to Transmit an Empty Buffer If the symbol just read was the Transmit Buffer symbol and the Code 39 buffer is empty: • • •

A short lo/hi/lo beep signals that the buffer is empty. No transmission occurs. The buffer remains empty.

Code 93 Enable/Disable Code 93 Parameter # 09h To enable or disable Code 93, scan the appropriate bar code below.

Enable Code 93 (01h)

*Disable Code 93 (00h)

Page 194

13-30 DS6608 Product Reference Guide

Set Lengths for Code 93 Parameter # L1 = 1Ah, L2 = 1Bh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 93 to any length, one or two discrete lengths, or lengths within a specific range. •

•

•

•

One Discrete Length - Select this option to decode only Code 93 symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only Code 93 symbols with 14 characters, scan Code 93 - One Discrete Length, then scan 1 followed by 4. To correct an error or to change the selection, scan Cancel on page D-4. Two Discrete Lengths - Select this option to decode only Code 93 symbols containing either of two selected lengths. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only those Code 93 symbols containing either 2 or 14 characters, select Code 93 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or to change the selection, scan Cancel on page D-4. Length Within Range - Select this option to decode a Code 93 symbol with a specific length range. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode Code 93 symbols containing between 4 and 12 characters, first scan Code 93 - Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). To correct an error or change the selection, scan Cancel on page D-4. Any Length - Scan this option to decode Code 93 symbols containing any number of characters within the digital scanner’s capability.