Page 175

Symbologies 13-11

Enable/Disable UPC-E1 Parameter # 0Ch UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below. UPC-E1 is not a UCC (Uniform Code Council) approved symbology.

Note

Enable UPC-E1 (01h)

*Disable UPC-E1 (00h)

Enable/Disable EAN-8/JAN-8 Parameter # 04h To enable or disable EAN-8/JAN-8, scan the appropriate bar code below.

*Enable EAN-8/JAN-8 (01h)

Disable EAN-8/JAN-8 (00h)

Page 176

13-12 DS6608 Product Reference Guide

Enable/Disable EAN-13/JAN-13 Parameter # 03h To enable or disable EAN-13/JAN-13, scan the appropriate bar code below.

*Enable EAN-13/JAN-13 (01h)

Disable EAN-13/JAN-13 (00h)

Enable/Disable Bookland EAN Parameter # 53h To enable or disable Bookland EAN, scan the appropriate bar code below.

Enable Bookland EAN (01h)

*Disable Bookland EAN (00h)

Page 177

Symbologies 13-13

Decode UPC/EAN/JAN Supplementals Parameter # 10h Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN 13+2). Six options are available. • • • •

•

•

If Decode UPC/EAN/JAN Only With Supplementals is selected, UPC/EAN/JAN symbols without supplementals are not decoded. If Ignore Supplementals is selected, and the digital scanner is presented with a UPC/EAN/JAN with a supplemental, the UPC/EAN/JAN is decoded and the supplemental bar code is ignored. An Autodiscriminate Option is also available. If this option is selected, choose an appropriate UPC/EAN/JAN Supplemental Redundancy value from the next page. A value of 5 or more is recommended. Enable 378/379 Supplemental Mode to delay only EAN-13/JAN-13 bar codes starting with a ‘378’ or ‘379’ prefix by the supplemental search process. All other UPC/EAN/JAN bar codes are exempt from the search and are reported instantly upon decode. Select Enable 978 Supplemental Mode to delay only EAN-13/JAN-13 bar codes starting with a ‘978’ prefix by the supplemental search process. All other UPC/EAN/JAN bar codes are exempt from the search and are reported instantly upon decode. Select Enable Smart Supplemental Mode to delay only EAN-13/JAN-13 bar codes starting with a ‘378’, ‘379’, or ‘978’ prefix by the supplemental search process. All other UPC/EAN/JAN bar codes are exempt from the search and are reported instantly upon decode. To minimize the risk of invalid data transmission, select either to decode or ignore supplemental characters.

Note

Decode UPC/EAN/JAN Only With Supplementals (01h)

*Ignore Supplementals (00h)

Autodiscriminate UPC/EAN/JAN Supplementals (02h)

Page 178

13-14 DS6608 Product Reference Guide

Decode UPC/EAN/JAN Supplementals (continued)

Enable 378/379 Supplemental Mode (04h)

Enable 978 Supplemental Mode (05h)

Enable Smart Supplemental Mode (03h)

UPC/EAN/JAN Supplemental Redundancy Parameter # 50h With Autodiscriminate UPC/EAN/JAN Supplementals selected, this option adjusts the number of times a symbol without supplementals is decoded before transmission. The range is from two to thirty times. Five or above is recommended when decoding a mix of UPC/EAN/JAN symbols with and without supplementals, and the autodiscriminate option is selected. The default is set at 10. Scan the bar code below to set a decode redundancy value. Next, scan two numeric bar codes in Appendix D, Numeric Bar Codes. Single digit numbers must have a leading zero. To correct an error or change a selection, scan Cancel on page D-4.

UPC/EAN/JAN Supplemental Redundancy

Page 179

Symbologies 13-15

Transmit UPC-A Check Digit Parameter # 28h The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-A check digit. It is always verified to guarantee the integrity of the data.

*Transmit UPC-A Check Digit (01h)

Do Not Transmit UPC-A Check Digit (00h)

Transmit UPC-E Check Digit Parameter # 29h The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-E check digit. It is always verified to guarantee the integrity of the data.

*Transmit UPC-E Check Digit (01h)

Do Not Transmit UPC-E Check Digit (00h)

Page 180

13-16 DS6608 Product Reference Guide

Transmit UPC-E1 Check Digit Parameter # 2Ah The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-E1 check digit. It is always verified to guarantee the integrity of the data.

*Transmit UPC-E1 Check Digit (01h)

Do Not Transmit UPC-E1 Check Digit (00h)

UPC-A Preamble Parameter # 22h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-A preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system.

No Preamble (<DATA>) (00h)

*System Character (<SYSTEM CHARACTER> <DATA>) (01h)

System Character & Country Code (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>) (02h)

Page 181

Symbologies 13-17

UPC-E Preamble Parameter # 23h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-E preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system.

No Preamble (<DATA>) (00h)

*System Character (<SYSTEM CHARACTER> <DATA>) (01h)

System Character & Country Code (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>) (02h)

Page 182

13-18 DS6608 Product Reference Guide

UPC-E1 Preamble Parameter # 24h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-E1 preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system.

No Preamble (<DATA>) (00h)

*System Character (<SYSTEM CHARACTER> <DATA>) (01h)

System Character & Country Code (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>) (02h)

Convert UPC-E to UPC-A Parameter # 25h Enable this to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). When disabled, UPC-E decoded data is transmitted as UPC-E data, without conversion.

Convert UPC-E to UPC-A (Enable) (01h)

*Do Not Convert UPC-E to UPC-A (Disable) (00h)

Page 183

Symbologies 13-19

Convert UPC-E1 to UPC-A Parameter # 26h Enable this to convert UPC-E1 decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). When disabled, UPC-E1 decoded data is transmitted as UPC-E1 data, without conversion.

Convert UPC-E1 to UPC-A (Enable) (01h)

*Do Not Convert UPC-E1 to UPC-A (Disable) (00h)

EAN-8/JAN-8 Extend Parameter # 27h When enabled, this parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols. When disabled, EAN-8 symbols are transmitted as is.

Enable EAN/JAN Zero Extend (01h)

*Disable EAN/JAN Zero Extend (00h)

Page 184

13-20 DS6608 Product Reference Guide

UCC Coupon Extended Code Parameter # 55h When enabled, this parameter decodes UPC-A bar codes starting with digit ‘5’, EAN-13 bar codes starting with digit ‘99’, and UPCA/EAN-128 Coupon Codes. UPCA, EAN-13, and EAN-128 must be enabled to scan all types of Coupon Codes.

Enable UCC Coupon Extended Code (01h)

*Disable UCC Coupon Extended Code (00h)

Use the Decode UPC/EAN Supplemental Redundancy parameter to control autodiscrimination of the EAN128 (right half) of a coupon code.

Note

Code 128 Enable/Disable Code 128 Parameter # 08h To enable or disable Code 128, scan the appropriate bar code below.

*Enable Code 128 (01h)

Disable Code 128 (00h)