The text of a manual · part 9 of 46
Symbol DS6607 Product Reference Guide: User Preferences & Miscellaneous Scanner Options, pages 48 to 56
Pages 48 to 56 of 370, from Symbol DS6607 Product Reference Guide
The original document is the PDF (6.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol DS-6607
Page 48
4 - 10 Symbol DS6607 Product Reference Guide
Picklist Mode Parameter # F0h 92h Picklist mode enables the digital scanner to decode only bar codes that are aligned under the laser crosshair. Select one of the following picklist modes for the digital scanner:
• Disabled Always - Picklist mode is always disabled. • Enabled Out of Scanstand - Picklist mode is enabled when the digital scanner is out of Scanstand mode and disabled when the digital scanner is in Scanstand mode.
• Enabled Always- Picklist mode is always enabled.
*Disabled Always (00h)
Enabled Out of Scanstand (01h)
Enabled Always (02h)
Page 49
User Preferences & Miscellaneous Scanner Options 4 - 11
Decode Session Timeout Parameter # 88h This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds. To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from Appendix D, Numeric Bar Codes that correspond to the desired on time. Single digit numbers must have a leading zero. For example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar codes. To correct an error or change the selection, scan Cancel on page D-3.
Decode Session Timeout
Timeout Between Decodes, Same Symbol Parameter # 89h This option is used in hands-free (Intellistand) mode to prevent the beeper from continuously beeping when a symbol is left in the digital scanner’s field of view. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. The default interval is 0.6 seconds. To select the timeout between decodes for the same symbol, scan the bar code below, then scan two numeric bar codes from Appendix D, Numeric Bar Codes that correspond to the desired interval, in 0.1 second increments.
Timeout Between Decodes, Same Symbol
Page 50
4 - 12 Symbol DS6607 Product Reference Guide
Beep After Good Decode Parameter # 38h Scan a bar code below to select whether or not the digital scanner beeps after a good decode. If selecting Do Not Beep After Good Decode, the beeper still operates during parameter menu scanning and to indicate error conditions.
*Beep After Good Decode (Enable) (01h)
Do Not Beep After Good Decode (Disable) (00h)
Page 51
User Preferences & Miscellaneous Scanner Options 4 - 13
Miscellaneous Scanner Parameters Transmit Code ID Character Parameter # 2Dh A Code ID character identifies the code type of a scanned bar code. This is useful when the digital scanner is decoding more than one code type. In addition to any single character prefix already selected, the Code ID character is inserted between the prefix and the decoded symbol. Select no Code ID character, a Symbol Code ID character, or an AIM Code ID character. For Code ID Characters, see Symbol Code Identifiers on page B-1 and AIM Code Identifiers on page B-2.
Symbol Code ID Character (02h)
AIM Code ID Character (01h)
*None (00h)
Page 52
4 - 14 Symbol DS6607 Product Reference Guide
Prefix/Suffix Values Key Category Parameter # P = 63h, S1 = 62h, S2 = 64h Decimal Value Parameter # P = 69h, S1 = 68h, S2 = 6Ah A prefix and/or one or two suffixes can be appended to scan data for use in data editing. To set a value for a prefix or suffix, scan a four-digit number (i.e., four bar codes from Appendix D, Numeric Bar Codes) that corresponds to that value. See Table E-1 on page E-1 for the four-digit codes. When using host commands to set the prefix or suffix, set the key category parameter to 1, then set the 3-digit decimal value. See Table E-1 on page E-1 for the four-digit codes. To correct an error or change a selection, scan Cancel on page D-3. NOTE
To use Prefix/Suffix values, first set the Scan Data Transmission Format on page 4-15.
Scan Prefix (07h)
Scan Suffix 1 (06h)
Scan Suffix 2 (08h)
Data Format Cancel
Page 53
User Preferences & Miscellaneous Scanner Options 4 - 15
Scan Data Transmission Format Parameter # EBh To change the scan data format, scan one of the following eight bar codes corresponding to the desired format. NOTE
If using this parameter do not use ADF rules to set the prefix/suffix.
To set values for the prefix and/or suffix, see Prefix/Suffix Values on page 4-14.
*Data As Is (00h)
<DATA> <SUFFIX 1> (01h)
<DATA> <SUFFIX 2> (02h)
<DATA> <SUFFIX 1> <SUFFIX 2> (03h)
<PREFIX> <DATA > (04h)
Page 54
4 - 16 Symbol DS6607 Product Reference Guide
Scan Data Transmission Format (continued)
<PREFIX> <DATA> <SUFFIX 1> (05h)
<PREFIX> <DATA> <SUFFIX 2> (06h)
<PREFIX> <DATA> <SUFFIX 1> <SUFFIX 2> (07h)
FN1 Substitution Values Key Category Parameter # 67h Decimal Value Parameter # 6Dh The Wedge and USB HID Keyboard hosts support a FN1 Substitution feature. When enabled any FN1 character (0x1b) in an EAN128 bar code is substituted with a value. This value defaults to 7013 (Enter Key). When using host commands to set the FN1 substitution value, set the key category parameter to 1, then set the 3-digit keystroke value. See the ASCII Character Set table for the currently installed host interface for the desired value. To select a FN1 substitution value via bar code menus: 1.
Scan the bar code below.
Set FN1 Substitution Value 2.
Look up the keystroke desired for FN1 Substitution in the ASCII Character Set table for the currently installed host interface. Enter the 4-digit ASCII Value by scanning each digit in Appendix D, Numeric Bar Codes.
To correct an error or change the selection, scan Cancel. To enable FN1 substitution for USB HID keyboard, scan the Enable FN1 Substitution bar code on page 8-10.
Page 55
User Preferences & Miscellaneous Scanner Options 4 - 17
Transmit “No Read” Message Parameter # 5Eh Scan a bar code below to select whether or not to transmit a No Read message. When enabled, the characters NR are transmitted when a bar code is not decoded. When disabled, if a symbol does not decode, nothing is sent to the host.
Enable No Read (01h)
*Disable No Read (00h)
Page 56
4 - 18 Symbol DS6607 Product Reference Guide