The text of a manual · part 7 of 46
Symbol DS6607 Product Reference Guide: Maintenance and Technical Specifications
Pages 33 to 38 of 370, from Symbol DS6607 Product Reference Guide
The original document is the PDF (6.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol DS-6607
Page 33
Chapter 3 Maintenance and Technical Specifications Introduction This chapter provides suggested scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts).
Maintenance Cleaning the scan window is the only maintenance required. A dirty window can affect scanning accuracy.
• Do not allow abrasive material to touch the window. • Remove any dirt particles with a damp cloth. • Wipe the window using a tissue moistened with ammonia/water. • Do not spray water or other cleaning liquids directly into the window.
Page 34
3-2
Symbol DS6607 Product Reference Guide
Troubleshooting Table 3-1 Troubleshooting
Problem The aiming pattern does not appear when pressing the trigger.
Possible Causes
Possible Solutions
No power to the digital scanner.
If the configuration requires a power supply, re-connect the power supply.
Incorrect host interface cable is used.
Connect the correct host interface cable.
Interface/power cables are loose.
Re-connect cables.
Digital scanner is disabled.
See the technical person in charge of scanning.
If using RS-232 Nixdorf B mode, CTS is not asserted.
Assert CTS line.
Aiming pattern is disabled.
Enable the aiming pattern. See Decode Aiming Pattern on page 5-5.
Scanner emits short low/short medium/short high beep sequence (power-up beep sequence) more than once.
The USB bus may put the digital scanner in a state where power to the digital scanner is cycled on and off more than once.
Normal during host reset.
Digital scanner emits aiming pattern, but does not decode the bar code.
Digital scanner is not programmed for the correct bar code type.
Program the digital scanner to read that type of bar code. See Chapter 10, Symbologies.
Bar code symbol is unreadable.
Scan test symbols of the same bar code type to determine if the bar code is defaced.
The symbol is not completely inside aiming pattern.
Move the symbol completely within the aiming pattern.
Digital scanner has not completed USB initialization.
Wait several seconds and scan again.
Digital scanner emits 4 short high beeps during decode attempt.
Page 35
Maintenance and Technical Specifications
3-3
Table 3-1 Troubleshooting (Continued)
Problem
Possible Causes
Possible Solutions
Digital scanner decodes bar code, but does not transmit the data to the host.
Digital scanner is not programmed for the correct host type.
Scan the appropriate host type programming bar code. See the chapter corresponding to the host type.
Interface cable is loose.
Re-connect the cable.
If 4 long low beeps are heard, a transmission error occurred.
Set the digital scanner's communication parameters to match the host's setting.
If 5 low beeps are heard, a conversion or format error occurred.
Configure the digital scanner's conversion parameters properly.
If lo/hi/lo beeps are heard, an invalid ADF rule is detected.
Program the correct ADF rules.
If hi/lo beeps are heard, the digital scanner is buffering Code 39 data.
Normal scanning a Code 39 bar code and the Code 39 Buffering option is enabled.
Digital scanner is not programmed to work with the host.
Scan the appropriate host type programming bar code.
Host displays scanned data incorrectly.
For RS-232, set the digital scanner's communication parameters to match the host's settings. Program the proper editing options (e.g., UPC-E to UPC-A Conversion). Digital scanner emits hi/hi/hi/Lo beeps when not in use.
RS-232 receive error.
Normal during host reset. Otherwise, set the digital scanner's RS-232 parity to match the host setting.
Digital scanner emits lo/hi beeps during programming.
Input error or Cancel bar code was scanned.
Scan the correct numeric bar codes within range for the parameter programmed.
Digital scanner emits lo/hi/lo/hi beeps during programming.
Out of ADF parameter storage space.
Erase all rules and re-program with shorter rules.
Digital scanner emits lo/hi/lo beeps.
Clearing Code 39 buffer.
Normal when scanning the Code 39 Buffering Clear Buffer bar code or upon attempt to transmit an empty Code 39 buffer.
Digital scanner emits a power-up beep after changing USB host type.
The USB bus re-established power to the digital scanner.
Normal when changing USB host type.
Digital scanner emits one high beep when not in use.
In RS-232 mode, a <BEL> character was received and Beep on <BEL> option is enabled.
Normal when Beep on <BEL> is enabled and the digital scanner is in RS-232 mode.
Page 36
3-4
Symbol DS6607 Product Reference Guide
If after performing these checks the digital scanner still experiences problems, contact Motorola Enterprise Mobility Support. See page xiii for contact information.
NOTE
Technical Specifications Table 3-2 Technical Specifications
Item
Description
Power Requirements
5 VDC + / - 10% @ approximately 220 mA RMS (nominal), 500 mA (max)
Power Source
Depending on host: Host powered External power supply, 5.2 V nominal
Decode Capability
UPC/EAN, UPC/EAN with supplementals, UCC/EAN, JAN 8 & 13, 128, Code 39, Code 39 Full ASCII, Code 39 Trioptic, Codabar (NW7), Interleaved 2 of 5, Discrete 2 of 5, IATA 2 of 5, Code 128, Code 93, MSI, Code 11, Code 32, Coupon Code, Bookland EAN, GS1 DataBar, US Postnet, US Planet, UK Postal, Japan Postal, Australia Postal, Dutch Postal, Composite Codes, PDF417, MicroPDF, Maxicode, Data Matrix (ECC 200), QR Code.
Beeper Operation
User-selectable: enable, disable
Beeper Volume
User-selectable: three levels
Beeper Tone
User-selectable: three tones
Yaw Tolerance
± 50° from normal
Pitch Tolerance
± 60° from normal
Roll Tolerance
± 180° from normal
Print Contrast Minimum
25% minimum reflectance differential, measured at 650 nm.
Ambient Light Immunity
10,000 Ft Candles (107,600 Lux)
Durability
6 ft (1.8 m) drop to concrete
Operating Temperature
32° to 122° F (0° to 50° C)
Storage Temperature
-40° to 158° F (-40° to 70° C)
Humidity
5% to 95% (non-condensing)
Weight (without cable)
6.4 oz. (181.4 g)
Dimensions: Height Width Depth
6.55 in. (16.64 cm) 2.82 in. (7.16 cm) 4.72 in. (11.99 cm)
Page 37
Maintenance and Technical Specifications
Table 3-2 Technical Specifications (Continued)
Item
Description
Laser
650nm laser diode
Laser Classifications
IEC 825-1 Class 2
ESD
15 kV area discharge 8 kV contact discharge
Minimum Element Width
5 mil (0.127 mm)
Interfaces Supported
SSI, RS-232, USB
Electrical Safety
UL1950, CSA C22.2 No.950. EN60950/IC950
Input Transient Protection
IEC 1000-4-(2,3,4,5,6,11)
EMI
FCC Part 15 Class B, ICES-003 Class B European Union EMC Directive, Japan VCCI/MITI/Dentori
Digital Scanner Signal Descriptions Bottom of digital scanner
Cable interface port
Pin 10
Pin 1
Interface cable modular connector
Figure 3-1 Digital Scanner Cable Pinouts
3-5
Page 38
3-6
Symbol DS6607 Product Reference Guide
The signal descriptions in Table 3-3 apply to the connector on the digital scanner and are for reference only. Table 3-3 Digital Scanner Signal Pin-outs
Pin
RS-232/SSI
USB
1
Reserved
Jump to Pin 6
2
Power
Power
3
Ground
Ground
4
TxD
Reserved
5
RxD
D+
6
RTS
Jump to Pin 1
7
CTS
D-
8
Reserved
Reserved
9
Reserved
Reserved
10
Reserved
Reserved