Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 39 of 46

Symbol DS6607 Product Reference Guide: Standard Default Parameters

Pages 317 to 324 of 370, from Symbol DS6607 Product Reference Guide

The original document is the PDF (6.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol DS-6607

Page 317

Appendix A Standard Default Parameters

Table A-1

Standard Default Parameters Table Parameter

Parameter Number

Default

Page Number

User Preferences Set Default Parameter

All Defaults

4-4

Parameter Scanning

ECh

Enable

4-4

Beeper Tone

91h

Medium

4-5

Beeper Volume

8Ch

High

4-6

Power Mode

80h

Continuous On

4-6

Time Delay to Low Power Mode

92h

1 Minute

4-7

Trigger Mode

8Ah

Auto Aim

4-9

Picklist Mode

F0h 92h

Disabled Always

4-10

Decode Session Timeout

88h

9.9 Sec

4-11

Timeout Between Decodes, Same Symbol

89h

0.6 Sec

4-11

Beep After Good Decode

38h

Enable

4-12

Transmit Code ID Character

2Dh

None

4-13

Prefix Value

63h, 69h

7013 <CR><LF>

4-14

Suffix 1 Value Suffix 2 Value

62h, 68h 64h, 6Ah

7013 <CR><LF>

4-14

Miscellaneous Scanner Options

1User selection is required to configure this interface and this is the most common selection.

Page 318

A-2

Symbol DS6607 Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Scan Data Transmission Format

EBh

Data as is

4-15

FN1 Substitution Values

67h, 6Dh

Set

4-16

Transmit “No Read” Message

5Eh

Disable

4-17

Decoding Illumination

F0h 2Ah

Enable

5-5

Decode Aiming Pattern

F0h 32h

Enable

5-5

Image Capture Autoexposure

F0h 68h

Enable

5-6

Image Capture Illumination

F0h 69h

Enable

5-6

Gain

F4h F0h A7h

100

5-7

Exposure Time

F4h F0h 38h

10 ms

5-7

Snapshot Mode Timeout

F0h 43h

0 (30 seconds)

5-8

Snapshot Aiming Pattern

F0h 2Ch

Enable

5-9

Image Cropping

F0h 2Dh

Disable

5-9

Crop to Pixel Addresses

F4h F0h 3Bh; F4h F0h 3Ch; F4h F0h 3Dh; F4h F0h 3Eh

0 top, 0 left, 479 bottom, 639 right

5-10

Image Resolution

F0h 2Eh

Full

5-11

JPEG Image Options

F0h 2Bh

Quality

5-12

JPEG Quality Value

F0h 31h

65

5-12

JPEG Size Value

F0h 33h

40 (41K)

5-12

Image File Format Selection

F0h 30h

JPEG

5-13

Bits per Pixel (BPP)

F0h 2Fh

8 BPP

5-14

Signature Capture

5Dh

Disable

5-15

Signature Capture Image File Format Selection

F0h 39h

JPEG

5-16

Signature Capture Bits per Pixel (BPP)

F0h 3Ah

8 BPP

5-17

Signature Capture Width

F4h F0h 6Eh

400

5-17

Signature Capture Height

F4h F0h 6Fh

100

5-18

Signature Capture JPEG Quality

F0h A5h

65

5-18

Imaging Preferences

1

User selection is required to configure this interface and this is the most common selection.

Page 319

Standard Default Parameters

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Video View Finder

F0h 44h

Disable

5-19

Target Video Frame Size

F0h 48h

2200 bytes

5-19

Video View Finder Image Size

F0h 49h

1700 bytes

5-20

Baud Rate

9Ch

9600

6-4

Parity

9Eh

None

6-6

Check Parity

97h

Enable

6-7

Software Handshaking

9Fh

ACK/NAK

6-7

Host RTS Line State

9Ah

Low

6-8

Decode Data Packet Format

EEh

Send Raw Decode Data

6-8

Stop Bits

9Dh

1

6-9

Host Serial Response Time-out

9Bh

2 sec

6-10

Host Character Time-out

EFh

200 msec

6-11

Multipacket Option

F0h 4Eh

Option 1

6-12

Interpacket Delay

F0h 4Fh

0 ms

6-13

Decode Event

F0h 00h

Disable

6-14

Boot Up Event

F0h 02h

Disable

6-15

Parameter Event

F0h 03h

Disable

6-15

RS-232 Host Types

Standard1

7-6

Baud Rate

9600

7-7

Parity Type

None

7-9

Stop Bit Select

1 Stop Bit

7-10

Data Bits

8-Bit

7-10

Check Receive Errors

Enable

7-10

Hardware Handshaking

None

7-12

Software Handshaking

None

7-14

SSI Host Preferences

Event Reporting

RS-232 Host Parameters

1

User selection is required to configure this interface and this is the most common selection.

A-3

Page 320

A-4

Symbol DS6607 Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Host Serial Response Time-out

2 Sec

7-16

RTS Line State

Low RTS

7-17

Beep on <BEL>

Disable

7-17

Intercharacter Delay

0 msec

7-18

Nixdorf Beep/LED Options

Normal Operation

7-19

Ignore Unknown Characters

Send Bar Code

7-19

USB Device Type

HID Keyboard Emulation

8-4

Symbol Native API (SNAPI) Status Handshaking

Enable

8-5

USB Country Keyboard Types (Country Codes)

North American

8-6

USB Keystroke Delay

No Delay

8-8

USB CAPS Lock Override

Disable

8-8

USB Ignore Unknown Characters

Enable

8-9

Emulate Keypad

Disable

8-9

Emulate Keypad with Leading Zero

Disable

8-10

USB Keyboard FN1 Substitution

Disable

8-10

Function Key Mapping

Disable

8-11

Simulated Caps Lock

Disable

8-11

Convert Case

No Case Conversion

8-11

None1

9-2

USB Host Parameters

123Scan Configuration Tool 123Scan Configuration UPC/EAN UPC-A

01h

Enable

10-7

UPC-E

02h

Enable

10-7

UPC-E1

0Ch

Disable

10-8

EAN-8/JAN 8

04h

Enable

10-8

EAN-13/JAN 13

03h

Enable

10-9

1User selection is required to configure this interface and this is the most common selection.

Page 321

Standard Default Parameters

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Bookland EAN

53h

Disable

10-9

Decode UPC/EAN/JAN Supplementals (2 and 5 digits)

10h

Ignore

10-10

User-Programmable Supplementals Supplemental 1: Supplemental 2:

10-13 F1h 43h F1h 44h

UPC/EAN/JAN Supplemental Redundancy

50h

10

10-13

Transmit UPC-A Check Digit

28h

Enable

10-14

Transmit UPC-E Check Digit

29h

Enable

10-14

Transmit UPC-E1 Check Digit

2Ah

Enable

10-15

UPC-A Preamble

22h

System Character

10-16

UPC-E Preamble

23h

System Character

10-17

UPC-E1 Preamble

24h

System Character

10-18

Convert UPC-E to A

25h

Disable

10-19

Convert UPC-E1 to A

26h

Disable

10-19

EAN-8/JAN-8 Extend

27h

Disable

10-20

Bookland ISBN Format

F1h 40h

ISBN-10

10-21

UCC Coupon Extended Code

55h

Disable

10-22

Code 128

08h

Enable

10-23

UCC/EAN-128

0Eh

Enable

10-23

ISBT 128

54h

Enable

10-24

Code 39

00h

Enable

10-25

Trioptic Code 39

0Dh

Disable

10-25

Convert Code 39 to Code 32 (Italian Pharmacy Code)

56h

Disable

10-26

Code 32 Prefix

E7h

Disable

10-26

Set Length(s) for Code 39

12h 13h

2 to 55

10-27

Code 128

Code 39

1

User selection is required to configure this interface and this is the most common selection.

A-5

Page 322

A-6

Symbol DS6607 Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Code 39 Check Digit Verification

30h

Disable

10-28

Transmit Code 39 Check Digit

2Bh

Disable

10-29

Code 39 Full ASCII Conversion

11h

Disable

10-29

Buffer Code 39

71h

Disable

10-30

Code 93

09h

Disable

10-32

Set Length(s) for Code 93

1Ah 1Bh

4 to 55

10-33

Code 11

0Ah

Disable

10-35

Set Lengths for Code 11

1Ch 1Dh

4 to 55

10-35

Code 11 Check Digit Verification

34h

Disable

10-37

Transmit Code 11 Check Digit(s)

2Fh

Disable

10-38

Interleaved 2 of 5 (ITF)

06h

Enable

10-38

Set Lengths for I 2 of 5

16h 17h

14

10-39

I 2 of 5 Check Digit Verification

31h

Disable

10-40

Transmit I 2 of 5 Check Digit

2Ch

Disable

10-41

Convert I 2 of 5 to EAN 13

52h

Disable

10-41

Discrete 2 of 5

05h

Disable

10-42

Set Length(s) for D 2 of 5

14h 15h

12

10-42

Codabar

07h

Disable

10-44

Set Lengths for Codabar

18h 19h

5 to 55

10-44

CLSI Editing

36h

Disable

10-46

NOTIS Editing

37h

Disable

10-46

Code 93

Code 11

Interleaved 2 of 5 (ITF)

Discrete 2 of 5 (DTF)

Codabar (NW - 7)

1

User selection is required to configure this interface and this is the most common selection.

Page 323

Standard Default Parameters

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

MSI MSI

0Bh

Disable

10-47

Set Length(s) for MSI

1Eh 1Fh

4 to 55

10-47

MSI Check Digits

32h

One

10-49

Transmit MSI Check Digit

2Eh

Disable

10-49

MSI Check Digit Algorithm

33h

Mod 10/Mod 10

10-50

Inverse 1D

F1h 4Ah

Regular

10-51

US Postnet

59h

Enable

10-52

US Planet

5Ah

Enable

10-52

Transmit US Postal Check Digit

5Fh

Enable

10-53

UK Postal

5Bh

Enable

10-53

Transmit UK Postal Check Digit

60h

Enable

10-54

Japan Postal

F0h 22h

Enable

10-54

Australian Postal

F0h 23h

Enable

10-55

Dutch Postal

F0h 46h

Enable

10-55

4State Postal

F1h 50h

Disable

10-56

GS1 DataBar-14

F0h 52h

Enable

10-57

GS1 DataBar Limited

F0h 53h

Enable

10-57

GS1 DataBar Expanded

F0h 54h

Enable

10-58

Convert GS1 DataBar to UPC/EAN

F0h 8Dh

Disable

10-58

Composite CC-C

F0h 55h

Disable

10-59

Composite CC-A/B

F0h 56h

Disable

10-59

Composite TLC-39

F0h 73h

Disable

10-60

UPC Composite Mode

F0h 58h

Always Linked

10-61

Postal Codes

GS1 DataBar

Composite

1

User selection is required to configure this interface and this is the most common selection.

A-7

Page 324

A-8

Symbol DS6607 Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Composite Beep Mode

F0h 8Eh

Beep As Each Code Type is Decoded

10-62

UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes

F0h ABh

Disable

10-62

PDF417

0Fh

Enable

10-63

MicroPDF417

E3h

Disable

10-63

Code 128 Emulation

7Bh

Disable

10-64

Data Matrix

F0h 24h

Enable

10-65

DataMatrix Inverse

F1h 4Ch

Regular

10-65

Maxicode

F0h 26h

Enable

10-66

QR Code

F0h 25h

Enable

10-66

MicroQR

F1h 3Dh

Enable

10-67

QR Inverse

F1h 4Bh

Regular

10-67

Aztec

F1h 3Eh

Enable

10-68

Aztec Inverse

F1h 4Dh

Regular

10-68

Redundancy Level

4Eh

1

10-69

Security Level

4Dh

1

10-71

Intercharacter Gap Size

F0h 7Dh

Normal

10-72

2D Symbologies

Symbology-Specific Security Levels

Report Version

10-72

Macro PDF Flush Macro PDF Buffer

10-73

Abort Macro PDF Entry

10-73

1

User selection is required to configure this interface and this is the most common selection.