Page 235

Advanced Data Formatting 11 - 21

Message Containing A Specific Data String Use this feature to select whether the formatting affects data that begins with a specific character or data string, or contains a specific character or data string. There are 4 features:

• Specific String at Start • Specific String, Any Location • Any Message OK • Rule Belongs to Set

Specific String at Start Scan this bar code, then scan the bar codes representing the desired character or characters (up to a total of 8) in the Alphanumeric Keyboard on page 11-88. After scanning the following bar code: 1.

Enter a string using the Alphanumeric Keyboard on page 11-88.

2.

Scan End of Message on page 11-97.

Specific String At Start

Specific String, Any Location Scan this bar code, then, using the Numeric Keypad on page 11-22, scan a two-digit number representing the position (use a leading “zero” if necessary). Then scan the desired character or characters (up to a total of 8) on the Alphanumeric Keyboard on page 11-88, followed by the End of Message bar code on page 11-97. After scanning the following bar code: 1.

Enter a location using the Numeric Keypad on page 11-22.

2.

Enter a string using the Alphanumeric Keyboard on page 11-88.

3.

Scan End of Message on page 11-97.

Specific String Any Location

Any Message OK By not scanning any bar code, all selected code types are formatted, regardless of information contained.

Page 236

11 - 22 Symbol DS6607 Product Reference Guide

Numeric Keypad Bar codes on this page should not be confused with those on the alphanumeric keyboard.

0

1

2

3

4

5

6

Page 237

Advanced Data Formatting 11 - 23

Numeric Keypad (continued)

7

8

9

Cancel

Page 238

11 - 24 Symbol DS6607 Product Reference Guide

Rule Belongs To Set Select the set a rule belongs to. (There are four possible rule sets.) See Alternate Rule Sets on page 11-3 for more information about rule sets. Scan a bar code below to select which set a rule belongs to.

Rule Belongs To Set 1

Rule Belongs To Set 2

Rule Belongs To Set 3

Rule Belongs To Set 4

Page 239

Advanced Data Formatting 11 - 25

Actions Select how to format the data for transmission.

Send Data Send all data that remains, send all data up to a specific character selected from the Alphanumeric Keyboard on page 11-88, or send the next N characters. N = any number from 1 to 254, selected from the Alphanumeric Keyboard. Use these bar codes to send data.

Send Data Up To Character

Send All Data That Remains

Send Next Character

Send Next 2 Characters

Send Next 3 Characters

Send Next 4 Characters

Page 240

11 - 26 Symbol DS6607 Product Reference Guide

Send Data (continued)

Send Next 5 Characters

Send Next 6 Characters

Send Next 7 Characters

Send Next 8 Characters

Send Next 9 Characters

Send Next 10 Characters

Send Next 11 Characters

Page 241

Advanced Data Formatting 11 - 27

Send Data (continued)

Send Next 12 Characters

Send Next 13 Characters

Send Next 14 Characters

Send Next 15 Characters

Send Next 16 Characters

Send Next 17 Characters

Send Next 18 Characters

Page 242

11 - 28 Symbol DS6607 Product Reference Guide

Send Data (continued)

Send Next 19 Characters

Send Next 20 Characters

Setup Field(s) Table 11-1 Setup Field(s) Definitions

Parameter

Description

Page

Move Cursor Move Cursor To a Character

Scan the Move Cursor To Character bar code on page 11-29, then any printable ASCII character from the Alphanumeric Keyboard. When this is used, the cursor moves to the position after the matching character. If the character is not there, the rule fails and ADF tries the next rule.

11-29

Move Cursor to Start of Data

Scan this bar code to move cursor to the beginning of the data.

11-29

Move Cursor Past a Character

This parameter moves the cursor past all sequential occurrences of a selected character. For example, if the selected character is ‘A’, then the cursor moves past ‘A’, ‘AA’, ‘AAA’, etc. Scan the Move Cursor Past Character bar code on page 11-29, then select a character from the Alphanumeric Keyboard. If the character is not there, the cursor does not move (i.e., has no effect).

11-29

Skip Ahead “N” Characters

Scan one of these bar codes to select the number of positions ahead to move the cursor.

11-30

Skip Back “N” Characters

Scan one of these bar codes to select the number of positions back to move the cursor.

11-31

Send Preset Value

Send Values 1 through 6 by scanning the appropriate bar code. These values must be set using the prefix/suffix values in Table 7-4 on page 7-20. Value 1 = Scan Suffix Value 2 = Scan Prefix Values 3-6 are not applicable

11-33

Page 243

Advanced Data Formatting 11 - 29

Move Cursor Scan a bar code below to move the cursor in relation to a specified character. Then enter a character by scanning a bar code from the Alphanumeric Keyboard on page 11-88.

NOTE

If there is no match when the rule is interpreted and the rule fails, the next rule is checked.

Move Cursor To Character

Move Cursor To Start

Move Cursor Past Character

Send Pause Scan the bar code below to insert a pause in the transmission of data. The length of this pause is controlled by the value of the Pause Duration parameter.

Send Pause

Page 244

11 - 30 Symbol DS6607 Product Reference Guide

Skip Ahead Use the following bar codes to skip ahead characters.

Skip Ahead 1 Character

Skip Ahead 2 Characters

Skip Ahead 3 Characters

Skip Ahead 4 Characters

Skip Ahead 5 Characters

Skip Ahead 6 Characters

Skip Ahead 7 Characters