Page 85
SSI Interface
6-9
Stop Bit Select Parameter # 9Dh The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving (host) device for the next character in the serial data stream. Set the number of stop bits (one or two) to match host device requirements.
*1 Stop Bit (01h)
2 Stop Bits (02h)
Page 86
6 - 10 Symbol DS6607 Product Reference Guide
Host Serial Response Time-out Parameter # 9Bh This parameter specifies how long the decoder waits for an ACK or NAK before resending. Also, if the decoder wants to send, and the host has already been granted permission to send, the decoder waits for the designated time-out before declaring an error. To set the delay period (options are 2, 5, 7.5, or 9,9 seconds), scan one of the following bar codes. NOTE
Other values are available via SSI command.
*Low - 2 Seconds (14h)
Medium - 5 Seconds (32h)
High - 7.5 Seconds (4Bh)
Maximum - 9.9 Seconds (63h)
Page 87
SSI Interface 6 - 11
Host Character Time-out Parameter # EFh This parameter determines the maximum time the decoder waits between characters transmitted by the host before discarding the received data and declaring an error. To set the delay period (options are 200, 500, 750, or 990 ms), scan one of the following bar codes. NOTE
Other values are available via SSI command.
*Low - 200 ms (0Ah)
Medium - 500 ms (32h)
High - 750 ms (4Bh)
Maximum - 990 ms (63h)
Page 88
6 - 12 Symbol DS6607 Product Reference Guide
Multipacket Option Parameter # F0h, 4Eh This parameter controls ACK/NAK handshaking for multi-packet transmissions.
• Multi-Packet Option 1: The host sends an ACK / NAK for each data packet during a multi-packet transmission.
• Multi-Packet Option 2: The digital scanner sends data packets continuously, with no ACK/NAK handshaking to pace the transmission. The host, if overrun, can use hardware handshaking to temporarily delay digital scanner transmissions. At the end of transmission, the digital scanner waits for a CMD_ACK or CMD_NAK.
• Multi-Packet Option 3: Option 3 is the same as option 2 with the addition of a programmable interpacket delay.
*Multipacket Option 1 (00h)
Multipacket Option 2 (01h)
Multipacket Option 3 (02h)
Page 89
SSI Interface 6 - 13
Interpacket Delay Parameter # F0h, 4Fh This parameter specifies the interpacket delay when Multipacket Option 3 is selected. To set the delay period (options are 0, 25, 50, 75, or 99 ms), scan one of the following bar codes. NOTE
Other values are available via SSI command.
*Minimum - 0 ms (00h)
Low - 25 ms (19h)
Medium - 50 ms (32h)
High - 75 ms (4Bh)
Maximum - 99 ms (63h)
Page 90
6 - 14 Symbol DS6607 Product Reference Guide
Event Reporting The host can request the digital scanner to provide certain information (events) relative to the digital scanner’s behavior. Enable or disable the events listed in Table 6-2 and on the following pages by scanning the appropriate bar codes. Table 6-2 Event Codes
Event Class
Code Reported
Event
Decode Event
Non parameter decode
0x01
Boot Up Event
System power-up
0x03
Parameter Event
Parameter entry error Parameter stored Defaults set (and parameter event is enabled by default) Number expected
0x07 0x08 0x0A 0x0F
Decode Event Parameter # F0h, 00h When enabled, the digital scanner generates a message to the host whenever a bar code is successfully decoded. When disabled, no notification is sent.
Enable Decode Event (01h)
*Disable Decode Event (00h)
Page 91
SSI Interface 6 - 15
Boot Up Event Parameter # F0h, 02h When enabled, the digital scanner generates a message to the host whenever power is applied. When disabled, no notification is sent.
Enable Boot Up Event (01h)
*Disable Boot Up Event (00h)
Parameter Event Parameter # F0h, 03h When enabled, the digital scanner generates a message to the host when one of the events specified in Table 6-2 on page 6-14 occurs. When disabled, no notification is sent.
Enable Parameter Event (01h)
*Disable Parameter Event (00h)
Page 92