Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 9 of 11

CB3000 Client Bridge User's Guide, pages 81 to 90

Pages 81 to 90 of 106

The original document is the PDF (3.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol CB-3000

Page 81

Administrative Options 5-7

• If importing, click the FTP Import or TFTP Import button. The system displays a confirmation window indicating the administrator must log out of the CB3000 after the operation completes for the changes to take effect. Click Yes to continue the operation, or No to cancel the configuration file import. • If exporting, click the FTP Export or TFTP Export button. The saved configuration file should be found/available on the specified FTP server.

5.3.2 Using HTTP To import or export a CB3000 configuration file using HTTP settings (local machine import/exports): 1. Select Tools > Configuration File from the CB3000 menu tree. The Config Import/Export screen displays. If using HTTP, only the bottom panel of the screen is used. 2. Continue, as appropriate, depending on whether you are importing or exporting a configuration file. If importing, follow these steps: • Click Browse to define a location on the system for the imported configuration file. • Click the Apply Uploaded File button to apply the configuration. If successful, the following message displays: Configuration file has successfully updated. Rebooting... Please wait. WARNING! Please wait 10 seconds before resetting the CB3000 after changing its configuration to avoid a disruption of operation and possible device hang. If exporting, follow these steps: • Click the Generate File button to generate the configuration data to export to a file (within the console system’s clipboard). • A few moments after a “Generate File done” message displays, click Download File. A File Download pop-up window appears.

Figure 5.5 File Download Dialog Box • Click Save. A dialog box prompts for a filename and location for the exported file (on the local machine or networked machine). Once the configuration file is saved, the Download Complete pop-up window appears.

Page 82

5-8 CB3000 Client Bridge User’s Guide

Figure 5.6 Download Complete Dialog Box • Click Open to open the file. As the file does not have an extension, the Open With pop-up window opens.

Figure 5.7 Open With Dialog Box • In the Open With pop-up window, select Internet Explorer and click OK to open the configfile with Internet Explorer. • Use Internet Explorer’s File > Save As dialog box to save the configfile as a text file.

Page 83

Administrative Options 5-9

Figure 5.8 Save File As Dialog Box • From the Save as Type drop-down, select Text File (*.txt). Click Save to save the file.

Page 84

5-10 CB3000 Client Bridge User’s Guide

5.4 Loading Firmware Motorola periodically releases updated versions of the CB3000 device firmware to the following URL: http://support.symbol.com/support/product/softwaredownloads.do If the CB3000 firmware version displayed on the Information or Troubleshooting screens are older than the version on the Web site, Motorola recommends updating the CB3000 to the latest firmware for full feature functionality. NOTE: The firmware file must be available from an FTP or TFTP site, or a locally networked machine to perform the update. To conduct a CB3000 firmware update: 1. Save the CB3000 current configuration before updating the firmware. After the update, the configuration file can be imported to restore the CB3000 to the settings before the update. See Importing or Exporting the Configuration File on page 5-5 for more information. WARNING! Be sure to save a copy of the CB3000’s configuration file before updating the firmware. 2. Select Tools > Load Firmware from the CB3000 menu tree. The Load Firmware screen displays.

Figure 5.9 Load Firmware Screen

Page 85

Administrative Options 5-11

3. Refer to the CB3000 Version displayed at the top of the screen to assess whether a firmware update is required. Compare the installed version with the version available at: http://support.symbol.com/support/product/softwaredownloads.do If a firmware update is required, proceed to step 4. 4. Get the firmware file from either an FTP/TFTP server, or locally, via HTTP, by clicking on the appropriate radio button in the upper and lower panels on the screen. 5. If loading the firmware file from a FTP/TFTP server, follow these steps (skip to step 6 for HTTP loads): a. Specify the name of the target firmware file within the File name field. File names should be in the format “cb3000_1.1.1.5”. b. If the target firmware file resides within a directory (once downloaded from the Web site), specify a complete path for the file within the File path field. c. Select either the FTP or TFTP server radio button, as required, to define whether the firmware file resides on a FTP or TFTP server. d. Set the following parameters: • IP Address – IP address for the FTP or TFTP server. • Username (for FTP server only) – Username to log into the server. • Password (for FTP server only) – Password associated with the username. e. Continue with step 7. 6. If loading the firmware file from a locally stored file (getting firmware file from HTTP), click the Browse button to navigate to the locally stored firmware update file. Continue with step 7. 7. Click the Upgrade button to initiate the update. Upon confirming the firmware update, the CB3000 reboots and completes the update. 8. Confirm the CB3000’s configuration is the same as before the firmware update. If they are not, import the configuration file saved prior to performing the update (step 1). See Importing or Exporting the Configuration File on page 5-5 for more details. WARNING! Please wait 10 seconds before resetting the CB3000 after changing its configuration to avoid a disruption of operation and possible device hang.

Page 86

5-12 CB3000 Client Bridge User’s Guide

5.5 Logging Settings The CB3000 continually logs system events which can prove useful later in assessing the throughput and performance of the CB3000 or troubleshooting problems on the CB3000-managed LAN. The type of event message and where they should be logged can also be configured from the CB3000 console. To configure event logging for the CB3000: 1. Select Tools > Logging Configurations from the CB3000 menu tree. The Logging Configurations screen displays.

Figure 5.10 Logging Configurations

2. Configure the logging level and log destination as required. • Logging Level – Select the desired log level for tracking system events. Eight standard UNIX/LINUX syslog levels are available: • 0 - Emergency. The system is unusable. • 1 - Alert. Action on these types of events must be taken immediately. • 2 - Critical. States a critical condition. • 3 - Errors. Describes an error. • 4 - Warning. Action should be taken as soon as possible. • 5 - Notice. A normal but important event. • 6 - Info. Nothing to do, since information only. • 7 - Debugging purposes only. • saved locally – Select this radio button to save the log file to the host to which the CB3000 is physically connected. Log entries are not saved in the CB3000. While the CB3000 is in operation, log data temporarily resides in memory. • syslog server – Select this radio button to enable an external syslog server to listen for incoming syslog messages and decode the messages into a log for viewing. Enter the IP address of an external syslog server in order to route the syslog events to that destination. • email – Select this radio button to configure the CB3000 to route log files to the email address and mail server designated. Configure the following parameters:

Page 87

Administrative Options 5-13

• eMail address – Enter an email address as the target destination for the log file. • Your Outgoing Mail Server– Enter the IP address of the outgoing mail server required to route the log file to the destination email address. 3. Click Apply to save any changes. 4. Click Undo Changes to undo any changes made. Configurations revert to the last saved configuration.

Page 88

5-14 CB3000 Client Bridge User’s Guide

5.6 Troubleshooting Options The CB3000 console includes utilities for testing IP network or local network communication issues between the device and host. These utilities (as well as a button to restore the CB3000 to its factory configuration) are available in the CB3000 Troubleshooting screen. Access the Troubleshooting screen by selecting Tools > Troubleshooting from the CB3000 menu tree. At the top of the screen, the Firmware version, MAC address and CB3000 serial number display.

Figure 5.11 Troubleshooting Screen

The following options exist within the Troubleshooting screen: Determine if a Firmware Update is Needed, Determine whether a firmware update is required by comparing the existing version against the latest version available on the Motorola Web site. Go to http://support.symbol.com/support/product/softwaredownloads.do to compare the versions. To update the firmware, see Loading Firmware on page 5-10. The MAC Address and Serial Number are hardcoded to the CB3000 during the manufacturing and are located on the bottom of the CB3000. Keep the MAC address and the serial number readily available since these addresses are required when contacting Symbol to report a problem. • Ping an Associated Device – The CB3000 can verify its link with an associated access point or networked peer (depending on the configured network mode) by sending WNMP ping packets to the device. To conduct a ping test with an associated device: a. Enter the IP address of the target device. b. Specify the length of each data packet transmitted to the target device during the ping test. This increment is defined in bytes. If you don’t know, enter a large arbitrary amount like 500. c. Specify the number of ping packets to transmit (in other words, the number of ping tests to perform).

Page 89

Administrative Options 5-15 d. Click the ICMP Ping Test button. Results of the ping test displays in the Status box.

Figure 5.12 Ping Test with Associated Device Status Example

Use the results to determine whether the device association should be maintained or replaced by a device association providing better network coverage and signal strength. • Ping the Host – The CB3000 can verify its link with its host by sending WNMP ping packets to the host’s IP address. To conduct an ICMP ping test with the CB3000’s host: a. Enter the IP address of the host. b. Specify the length of each data packet transmitted to the target device during the test. This increment is defined in bytes. If you don’t know, enter a large arbitrary amount like 500. c. Specify the number of ping packets to transmit. d. Click the Comm Connection Test button. Results of the test displays in the Status box.

Figure 5.13 Ping Test with Host Status Example e. Use this information to determine whether the host connection should be maintained or replaced by a host connection providing better connectivity with the CB3000.

Page 90

5-16 CB3000 Client Bridge User’s Guide