The text of a manual · part 3 of 4
CB3000 Client Bridge Installation Guide, pages 19 to 27
Pages 19 to 27 of 35
The original document is the PDF (592 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol CB-3000
Page 19
15
CB3000 Client Bridge Install Guide
If the CB3000’s security settings match the security settings of the ESSID, device association takes place without having to click Apply. However, if the CB3000’s security settings do not match the ESSID, the Security Settings page displays and the CB3000 is required to be configured to match the security settings of the target ESSID to ensure association compatibility. 5. Click Cancel to revert the WLAN Settings screen back to the last saved configuration. The CB3000 is now ready to have its Ethernet settings configured.
Configuring CB3000 Ethernet Settings Use the Ethernet Settings screen to specify the name of the CB3000 and assign network address information required as part of the CB3000 basic configuration: To configure required Ethernet settings for the CB3000: 1. Select Settings -> Ethernet Settings from the CB3000 menu tree.
Page 20
16
2. Configure the Ethernet Settings screen to assign a device name and set network address information the CB3000 uses to. Device Name
Specify a device name for the CB3000. Symbol recommends selecting a name serving as a reminder of the user base the CB3000 supports (engineering, retail etc.).
DHCP
Select the Obtain an IP address automatically checkbox if the CB3000 will use a DHCP server to obtain an IP address. Select the Use the following IP Address checkbox if an IP address is to entered manually (static) for the CB3000.
IP Address
The IP Address refers to the address other devices use to address the CB3000.
Subnet Mask
A subnet mask accompanies an IP address and the two values work together. Applying the subnet mask to an IP address splits the address into two parts, an "extended network address" and a host address.
Gateway IP Address
The Gateway IP Address is the address of the device providing the connection to the network.
Spanning Tree Protocol
Select the Spanning Tree Protocol checkbox to enable a technique that detects loops in a network and logically blocks redundant paths, thus ensuring only one route exists between any two LANs. Default is disabled.
3. Click Apply to save the settings within the Ethernet Settings screen. 4. Click Cancel to revert the screen back to the last saved configuration. The CB3000 is now ready to transmit and receive with a connected device in the open without security. However, Symbol recommends configuring a basic security scheme (for the purposes of our basic configuration, WEP 128) to ensure initial communication between the CB3000 and its connected device are protected.
Page 21
17
CB3000 Client Bridge Install Guide
Configuring CB3000 Security NOTE
For testing basic connectivity as described in this guide, there is no reason to enable Secure 802.1x authentication (an advanced authentication scheme). For details on configuring Secure 802.1x authentication, refer to the CB3000 User Guide available on the CB3000 product CDROM or go to the Symbol Web site (http://www.symbol.com/services/downloads) and download the guide.
Configuring CB3000 Basic Encryption Encryption applies a specific algorithm to data in order to alter its appearance and prevent unauthorized decoding. Decryption applies the algorithm in reverse to restore the data to its original form. Sender and receiver employ the same encryption/decryption method. Wired Equivalent Privacy (WEP) is a security protocol specified in the IEEE Wireless Fidelity (Wi-Fi) standard, 802.11b. WEP is designed to provide a WLAN with a level of security and privacy comparable to that of a wired LAN. WEP could be all that a small-business user needs for the simple encryption of wireless data. For the basic configuration and device connection described in this guide, WEP 128 encryption will be configured for the CB3000. WEP 128 ensures initial communications with the CB3000 are secure. To configure WEP 128 for the CB3000: 1. Select Settings -> Wireless Settings - > Security from the CB3000 menu tree. 2. Select WEP From the Security Mode drop-down menu.
Page 22
18
3. Use the Authentication Type drop-down menu to specify whether a shared key is implemented between the CB3000 and its associated device or no key is used (Open System). If a shared key is used, both the CB3000 and its connected device are required to use the same single key (as selected from 1 to 4) to interoperate. A shared key increases the level of security within the network as opposed sending information without one (Open System).
Page 23
19
CB3000 Client Bridge Install Guide
4. Use the Default Transmit Key checkboxes to specify which one key is used to transmit WEP algorithm information between the CB3000 and its associated device. NOTE
The CB3000 and its associated device are required to use the same key and key length to interoperate.
5. Select 128-bits from the WEP Encryption drop down menu. For WEP 128 (104-bit key), the keys are 26 hexadecimal characters in length. 6. Use the Passphrase algorithm checkboxes to specify whether the optional passphrase is a Symbol Passkey or a Generic Passphrase. PassKeys and pass phrases provides an easy to remember way of entering WEP key data without having to manually enter the keys each time WEP keys are created. Select Symbol PassKey to use a Symbol proprietary algorithm the CB3000 uses exclusively with other Symbol clients. The CB3000 decodes the PassKey into a set of 4 WEP keys using MD5 algorithms. The WEP keys display as alphanumeric text in the key fields until saved or the user navigates away from the WEP screen. Select Generic Passphrase if the CB3000 is sharing WEP keys with non-Symbol clients. The CB3000 decodes the passphrase into a set of 4 WEP keys, with the length depending on the 64 or 128 bit key length. The WEP keys display as alphanumeric text in the key fields until saved or the user navigates away from the WEP screen. 7. Specify a 4 to 32 character Passphrase and click the Generate Keys button. The passphase is helpful for entering WEP keys without having the remember all of the characters comprising the key. The passphase can be any alphanumeric string. The CB3000, other proprietary routers and Symbol devices use the algorithm to convert an ASCII string to the same hexadecimal number. This conversion is not required for a wireless connection. Wireless devices without Symbol adapters need to use WEP keys manually configured as hexadecimal numbers. 8. Click Apply to save the settings defined for WEP 128. 9. Click Cancel to revert the screen back to the last saved configuration. With a basic CB3000 device configuration set and WEP 128 defined for the CB3000 and its associated network device, the CB3000 is now ready to test for device connectivity.
Page 24
20
Testing Device Connectivity The CB3000 Web interface has a Troubleshooting screen with an ICMP Ping Test function. For the purposes of completing the CB3000 basic configuration and connection verification, this screen will be used to ping the CB3000’s associated device. To test CB3000 device connectivity: 1. Select Tools -> Troubleshooting from the CB3000 menu tree.
2. The CB3000 can verify its link with an associated access point by sending ping packets to the device. To conduct a ping test: a. Enter the IP address of the target device. b. Specify the length of each data packet transmitted to the target device during the ping test. This value is defined in bytes (The default is 32 bytes). c. Specify the number of ping packets to transmit (Symbol recommends 4 packets).
Page 25
21
CB3000 Client Bridge Install Guide d. Click the ICMP Ping Test button. Results of the ping test displays on the Status line. If the Status line displays Success, the CB3000 can interoperate with its associated access point. If not connected, go to CB3000 Troubleshooting on page -22.
Where to Go From Here? Once basic connectivity has been verified, the CB3000 can be fully configured to meet the needs of the network and the users it supports. The sections referenced below are located within the CB3000 Client Bridge User Guide available on your product CDROM or from the Symbol Web site (http://www.symbol.com/services/downloads). • Refer to Chapter 4 for information on configuring CB3000 network address information, and operational mode information. • Refer to Chapter 5 for information on configuring encryption (WEP, WPA1 and WPA2) and authentication (Secure 802.1x) security schemes. • Refer to Chapter 6 for information on accessing statistics helpful in monitoring the connection between the CB3000 and its connected devices.
Page 26
22
CB3000 Troubleshooting Symbol recommends the following troubleshooting tips before contacting the Support Center: Problem
Corrective Action
PWR LED is Off or Orange
Verify only the supplied power adapter is used and is plugged into a power supply appropriately rated for the country of operation. Unplug the power adapter and re-insert it back into the power outlet. If the problem persists, a hardware problem likely exists. Contact the Symbol Customer Support.
LAN LED is Off
Verify the cable connection is secure between the CB3000 and the PC’s LAN port. Ensure the computer network card is functioning properly.
Configuration updates lost or device hangs after reboot.
Wait at least 10 seconds after changing and saving the configuration before rebooting. If the CB3000 is hung, reset the device and implement your changes again.
CB3000 user interface hangs and cannot be navigated
Press Reset button on back of CB3000 unit for less than 10 seconds to reset the device. Press Reset button for 10 seconds or more to restore the CB3000 to its factory default configuration.
Discovery Tool Scan function does not display the CB3000 after changing the IP address (using the Discovery Tool).
Ensure the Ethernet port is set to 100Mb/full duplex on the PC/laptop. A valid IP address is also needed on the Ethernet port in order for the Discovery Tool Scan function to work properly. Ensure the computer’s VPN client is disabled before performing a Scan or the Scan will not function properly.
Page 27
23
CB3000 Client Bridge Install Guide
Technical Specifications CB3000 Technical Specifications Weight (with antenna) 0.65 lbs (0.30 kg) Dimensions
7 in. wide x 4 in. deep x 1.2 in. high (17.78 cm. wide x 10.16 cm. deep x 3.05 cm high) excluding external antenna and foot stand
Protocol Support
TCP/IP, DHCP
Standards Conformance
IEEE 802.11 IEEE 802.3 IEEE 802.1d IEEE 802.11a IEEE 802.11g IEEE 802.1x IEEE 802.3u HTTP
Network Architectures Infrastructure Ad-Hoc (Peer-to-Peer) Operating Frequencies 802.11a: 4.9 – 5.9 GHz 802.11b/g: 2.4 – 2.5 GHz Operating Channels
Country specific and bound by regulatory restrictions.
LAN (Ethernet) Connection Ethernet Frame
One 10/100 Base-T
Data Rate
IEEE 802.11a: 54, 48, 36, 24, 18, 12, 9, 6 Mbps IEEE 802.11b: 11, 5.5, 2, 1 Mbps IEEE 802.11g: 54, 48, 36, 24, 18, 12, 9, 6 Mbps
Modulation
IEEE 802.11a: Orthogonal Frequency Division Multiplexing (64QAM, 16QAM, QPSK and BPSK) IEEE 802.11b: Direct Sequence Spread Spectrum (CCK, DQPSK, DBPSK) IEEE 802.11g: Orthogonal Frequency Division Multiplexing (64QAM, 16QAM, QPSK and BPSK)
Security
64/128-Bit WEP IEEE 802.1x WPA/WPA-PSK
Peak Antenna Gain
3 dBi at 2.4 GHz 4 dBi at 5 GHz
Ethernet_II and IEEE 802.3
Operating Temperature 0 – 50° Celsius Storage Temperature
- 20 – 70° Celsius