For the Symbol CB-2000

Page 10

Diagram

In this diagram, the IBM SurePOS 700 connects to the Symbol CB-2000 through an Ethernet cable. The CB-2000 contains a WiFi 802.11b radio with an internal antenna. The CB-2000 transmits messages wirelessly to the Symbol Access Point, which forwards the messages to the IBM 4690 Controller over the Ethernet LAN.

Spectrum24 CB 2000 for IBM 4690 Terminals User Guide

10

Page 11

=====================================

Configuration Converting an Ethernet based 4694 or SurePOS terminal to a wireless terminal requires a few steps as described below. • • • •

Access Point Setup - Configuring the Access Point Client Bridge Setup - Configuring the Adapter/radio Terminal Setup - Configuring the terminal for wireless communications Controller Setup - Configuring logical names for application and performance.

Access Point Setup Both Symbol 802.11 and 802.11b Access Points are supported. The following fields must be configured prior to installation in the retail environment. • • •

The Net_ID (ESS) must be defined. The Multicast Mask (d) must be set to 03000004. Symbol strongly recommends enabling Kerberos or WEP (encryption).

This can be done through the Access Point’s User Interface (UI). The UI is a maintenance tool integrated into the AP. It provides statistical displays, AP configuration options and firmware upgrades. Access to the UI requires one of the following: • TCP/IP Telnet Client • Direct Serial Connection • Dial Up Access • SNMP Using a MIB Browser • Web Browser Refer to the Access Point Reference Guide for more details. The instructions below describe Configuring the parameters using the Direct Serial Connection. Assuming the UI and serial port are enabled on the AP: 1. Attach a null modem serial cable from the AP to the terminal or PC serial port. 2. From the terminal, start the communication program, such as HyperTerminal for Windows. 3. Select the correct COM port along with the following parameters. emulation ANSI baud rate 19200 bps data bits 8 stop bits 1 parity none

Spectrum24 CB 2000 for IBM 4690 Terminals User Guide

11

Page 12

flow control none There is no password requirement to view the Main Menu or statistics. 4. Press ESC to refresh the display. The AP displays the Main Menu. 5. From the Main Menu, Select Enter Admin Mode and enter the password. The default password is Symbol. Note: The password is case-specific. The entry will change to Exit Admin Mode if successful. 6. Enter the Net_ID (ESS). a. From the UI Main Menu, select AP Installation. b. Tab to Net_ID (ESS). c. Enter a unique value (1-32 alphanumeric characters, case sensitive) and press Enter twice. 7. Enter the Multicast Mask (d). a. From the UI Main Menu, select "Set RF Configuration". b. Tab to Multicast Mask (d). c. Enter 03000004. d. Press Enter twice to enter the configuration value. 8. Save the configuration. a. From the UI Main Menu, select Special Functions b. Tab to Save Configuration and press Enter. c. At the prompt “Are you sure? yes no”, press y to save. 9. Power the Access Point off and then on to reset. 10. Connect the Access Point to the IBM 4690 Controller’s Ethernet LAN. Client Bridge Setup The following setup is required prior to installation in the retail environment. • •

Set the Wireless LAN Service Area (ESSID) to match the Net_ID (ESS) on the AP. ESSID is case sensitive. Set “POS Setup” to “On” in the Client Bridge’s Advanced Wireless Network options. o Notes: CB-2000 firmware version 1.31 or later is required. Symbol 802.11b networks are supported. The security selected on the CB2000 must match the security that is available on the AP. Symbol strongly recommends enabling WEP (encryption) or Kerberos for security.

The Spectrum24 CB2000 Device Manager is an administration tool to select Spectrum24 CB2000 devices and launch their configurations in the Web browser. To configure a CB2000, the Device Manager is required to be installed on a computer that has an Ethernet adapter and is running one of the Windows operation systems and a Web browser listed in the Symbol CB2000 Client Bridge Quick Install Guide.

Spectrum24 CB 2000 for IBM 4690 Terminals User Guide

12

Page 13

If the IP address of the unit is known, the user can browse to it from another computer on the same subnet without use of the Device Manager. The Device Manager can display multiple CB2000s on a subnet as well as the properties of each one. Click on the Configure button to open a Web browser used for device configuration. For Device Manager installation, more CB2000 configuration details, or instructions on updating the CB firmware, refer to the Symbol CB2000 Client Bridge Quick Install Guide and the Symbol Spectrum24 CB2000 Client Bridge Product Reference Guide. The instructions below describe configuring the parameters using the Device Manager and a Web browser. 1. 2. 3. 4. 5.

Install the Device Manager on a Windows PC. Connect the CB2000 directly to a Windows PC with an Ethernet Cable. Power on the CB2000. Start the Device Manager on the Windows PC. In the Wireless Network Tree, select the device to configure. a. If more than one wireless LAN device appear in the tree, determine the right one by clicking Properties and checking the MAC address (serial number, located on the bottom of the device) to verify the correct device. 6. Click Configure. 7. If the selected device is on a different subnet, the Pre-IP Configuration Wizard is activated automatically. Use this wizard to configure the IP setting for the selected CB2000. It proposes IP address and subnet mask setting derived from the computer’s settings, so the selected device resides on the same subnet as the computer. Accept the suggested settings or change them as required. For more information, see “Using the PreIP Configuration Wizard” in the Spectrum24 CB2000 Client Bridge Product Reference Guide. 8. The next window prompts for an administrative password to allow the new IP address to be set. When the units are shipped from the factory, there is no administration password. Set an administration password and click Next. The Configuration Management System main page appears in the Web browser. 9. Verify the CB2000 firmware is 1.31 or later. The System Summary option under System Status reports the Firmware Version. If not 1.31 or later, obtain the latest firmware from Symbol and update the unit. Go to the Symbol Technology Website at http://www.symbol.com/services/downloads/dwnload_spec24_select.html to download firmware updates, drivers, tools, and documentation. For details on updating the firmware, refer to the Spectrum24 CB2000 Client Bridge Product Reference Guide’s section on Upgrade System. 10. Enter configuration parameters necessary for communicating with the network. See online help and the Spectrum24 CB2000 Client Bridge User Guide for additional information on setting and changing configuration settings. a. Under System Properties i. Enter a Device Name and Location to identify the CB2000. ii. Click “Apply All Changes” to save your settings.

Spectrum24 CB 2000 for IBM 4690 Terminals User Guide

13

Page 14

b. Under Wireless Network i. Set Network Mode to “Access Point (Infrastructure)” ii. Set the Wireless LAN Service Area to match the Net_ID (ESS) on the AP. iii. Channel Selection: When the network mode is Access Point (Infrastructure), this option is set to “Automatically select the best channel”. iv. Antenna Selection: The Workgroup Bridge contains two internal antennas, used by default (the Diversity setting). Refer to the CB2000 Client Bridge Product Reference Guide for more information. v. Click “Apply All Changes”. vi. Select “advanced wireless network configuration” 1. Network Traffic Accelerator 2. Data Preamble 3. POS Setup a. To load IBM terminals with the RPL protocol, set “POS Setup” to “On”. b. To load IBM terminals with the PXE protocol, set “POS Setup” to “Off”. c. To load IBM terminals with both the RPL and PXE protocols, set “POS Setup” to “On”. 4. Click “Apply All Changes”. 11. After saving the configuration, disconnect the bridge from the computer and connect it to the IBM 4694 or SurePOS 7xx terminal. 12. The CB is now ready to connect to the 4694 or SurePOS 7xx terminal(s). 13. To support one POS terminal, plug an Ethernet cable in the CB2000 from the POS terminal. IBM Terminal Setup There are no configuration changes to convert an Ethernet based 4694/SurePOS terminal from wired to wireless. Plug the Ethernet cable from the terminal into the Client Bridge. Reboot the Client Bridge and the terminal will be wireless. Multiple Terminal Support The CB2000 supports 1-4 POS terminals. To support one terminal, plug an Ethernet cable from the terminal into the Client Bridge. To support two to four terminals, plug an Ethernet cable from the Client Bridge into an uplink port on a hub. If the hub does not have an uplink port, plug a crossover Ethernet cable from the Client Bridge into any port on a hub. Plug up to four terminals into the hub. The Client Bridge supports up to four clients/terminals and keeps track of the clients with a list of MAC addresses. After the client limit is reached, a user removes an existing client and resets the client in the client list to allow a new client to associate with the network. To clear the Ethernet Client List on a CB2000: 1. Disconnect a client by unplugging its Ethernet cable from the hub or the bridge.

Spectrum24 CB 2000 for IBM 4690 Terminals User Guide

14

Page 15

2. Use the Spectrum24 CB2000 Device Manager to select the CB2000 and launch its configuration manager, or locate the IP address and http directly to the device via a Web browser. 3. Under “System Status”, click “Ethernet Client List”. 4. In the Ethernet Client List page, select the radio button next to the client to be removed and click “Clear Client List”. The bridge erases the client list for the selected client. 5. Connect the new client by plugging its Ethernet cable into the hub or the bridge. Note: New clients are added automatically to the list during the next network interaction. If the IBM 4690 POS terminals are configured with Locally Administered Addresses (LAA), each terminal uses two MAC addresses. This limits the number of terminals to two per Client Bridge. IBM 4690 Controller Setup Verify the 4690 OS level supports the CB-1000. To 4690 OS, the CB1000 and the CB2000 are functionally equivalent. IBM 4690 Controller Setup – RPL Settings This section describes the controller setup for loading terminals wirelessly with the RPL protocol. See the section on “PXE Loading” for setting up the controller for PXE loading. There are no required changes to the controller configuration, but several parameters are available to optimize the performance of wireless systems and reduce terminal load times. These parameters are changed using User Logical Names. The User Logical Names are: • • • •

ADXRPLWL - Selects Unicast vs. Multicast Remote Program Load ADXWLSPD - Speed-up terminal load. ADXSLLD4/ ADXLDLY4- Controller Throttle ADXWLNTO - Change the number of DLC retries.

ADXRPLWL - Unicast vs. Multicast Remote Program Load In a 4690 OS environment, 4694 and SurePOS terminals load their terminal OS images from a store controller in a multi-stage process. First, the hardware adapter responsible for the network connection to the store controller sends a broadcast message in search of a store controller. For LAN based hardware adapters (for example, token-ring, Ethernet, and wireless) the store controller discovery is performed using the Remote Program Load (RPL) protocol messages. When a store controller receives a load request from a hardware adapter, it first transmits a small piece of code, commonly referred to as a bootstrap, to the terminal. Once the bootstrap is loaded and control is transferred to it, the bootstrap requests the load of the 4690 terminal OS image from the store controller. When the 4690 terminal OS image is loaded, the bootstrap passes control to it and terminal IPL begins.

Spectrum24 CB 2000 for IBM 4690 Terminals User Guide

15

Page 16

The 1st Stage, the bootstrap load, is always transmitted to wireless terminals in unicast, or pointto-point, mode. In Stage 2, the terminal Operating System load, the OS can be transmitted either in the unicast or multicast mode. The final stage, application load, is always transmitted in unicast mode. Unicast mode means that the server transmits LAN data directly to the adapter, which issued the request. Multicast mode means that the server transmits LAN data to a group of adapters, which are all able to receive data addressed to a designated destination. Broadcast mode means that the server transmits LAN data to all adapters. Multicast is differentiated from broadcast as multicast data is sent to a certain group of adapters on the LAN (for example, all wireless adapters, but not Ethernet adapters). On wireless LANs, unicast transmissions are acknowledged at various points and provide higher reliability compared with multicast transmissions, which have a higher rate of data loss. Therefore, it is usually desirable to use unicast communications for wireless LANs. Although unicast transmissions are more reliable than multicast, the amount of data transmitted for a large number of terminals can be greater. In addition, unicast load time increases proportionally to the number of terminals being loaded. Conversely, in multicast mode load time increases only slightly with an increasing number of terminals; there is more of a leveling effect of load time as the number of terminals is increased. The 4690 OS RPL server is designed to transmit either multicast or unicast loads to wireless POS terminals. By default, the 4690 OS RPL servers will transmit in multicast mode. To override the multicast default setting and set the store controller to unicast mode, a user logical file name must be defined on the store controller(s) enabled for the wireless LAN feature. This file name, ADXRPLWL, will select whether the controller operates in a unicast or multicast mode for wireless terminals. Recommended Setting Unicast is preferred. It’s more reliable and loads a single terminal faster than multicast. However, multicast can load a large number of wireless terminals (15+) faster, especially in slower wireless networks. As the speed of the wireless network increases, the advantage of multicast goes down. If a location has 1-15 terminals on a 2Mbit wireless network, define ADXRPLWL to enable unicast loading. With more than 15 wireless terminals, do not define ADXRPLWL, which will enable multicast loading. If there are problems loading terminals, unicast is a more reliable load protocol. The number 15 is only a recommended number. It is best to experiment with both modes to determine which one provides the shortest, most reliable terminal load time. Notes: • Multicast is the default. • This option only affects the loading of 4690 OS into the terminal. During this load, the terminal displays U005.

Spectrum24 CB 2000 for IBM 4690 Terminals User Guide

16

Page 17

• • • •

A single terminal loads faster unicast than multicast. On faster wireless networks, unicast can support a higher number of terminals. The value assigned to ADXRPLWL is meaningless. The existence of the logical name forces unicast loading. This option only applies to RPL loaded terminals and doesn’t affect PXE loading.

To set Unicast Wireless RPL transmissions: 1. 2. 3. 4.

Sign on to the 4690 Master store controller. At the main menu, select Installation and Update Aids. Select Change Configuration Select Controller Configuration. Note: Perform the following steps on all Master and Alternate Master controllers that have the wireless feature installed and selected.

5. Select User Defined Logical File names. 6. Define logical file name ADXRPLWL. (When asked if it is OK to define this name with an IBM reserved name, answer yes.) 7. Define ADXRPLWL to 1. 8. Exit configuration. 9. Select Activate Configuration. 10. Select Controller Configuration. 11. After successful configuration activation, re-IPL all store controllers. The RPL server within the store controller(s) will now transmit the terminal operating system in unicast mode to wireless terminals. Wired Ethernet terminal loading will not be affected by this configuration change. To set Multicast Wireless RPL transmissions: 1. 2. 3. 4.

Sign on to the 4690 Master store controller. At the main menu, select Installation and Update Aids. Select Change Configuration. Select Controller Configuration. Note: Perform the following steps on all Master and Alternate Master controllers that have the wireless feature installed and selected.

5. Select User Defined Logical File names. 6. Erase logical file name ADXRPLWL. (When asked if it is OK to erase this name with an IBM reserved name, answer yes.) 7. Exit configuration. 8. Select Activate Configuration. 9. Select Controller Configuration. 10. After successful configuration activation, re-IPL all store controllers.

Spectrum24 CB 2000 for IBM 4690 Terminals User Guide

17

Page 18

The RPL server within the store controller(s) will now transmit the terminal operating system in multicast mode to wireless terminals. Wired Ethernet terminal loading will not be affected by this configuration change. ADXWLSPD - Speed-up wireless terminal loading This parameter may be used with wireless networks faster than 1Mbps. The terminal load time can be reduced significantly when a proper value for this parameter is set. When loading a wireless terminal, the controller delays about 60ms between each RPL load block to avoid overrunning the bandwidth of the wireless network. ADXWLSPD controls the number of load blocks sent per delay. The default is one block per delay. The default delay was designed for a dual controller system with a 1Mbps network. Since the controller can’t detect the speed of the wireless terminals, the user can configure ADXWLSPD to speed up the load. Recommended Setting Set this parameter based on the slowest wireless terminal in the network. Note that an 11Mbit radio may scale back to 5.5 or 2 or 1 Mbps based on the radio signal from the AP. The recommended setting is close to the speed of the slowest wireless terminal. This option only applies to RPL loaded terminals and doesn’t affect PXE loading. Speed of slowest wireless terminal 1Mbit 2Mbit 5Mbit 11Mbit

Recommended setting ADXWLSPD = 1 (Default) ADXWLSPD = 3 ADXWLSPD = 5 ADXWLSPD = 10

Warning: Setting this value too high will cause the controller to send blocks faster than the wireless network can transmit them. This causes load blocks to be thrown away and terminals will take a long time to load. ADXWLSPD works by being defined to a value n. If ADXWLSPD is not defined, the default value is 1. Base 4690 OS does not define this Logical Name. To define the User Logical Name ADXWLSPD: 1. Sign on to the 4690 Master store controller. 2. At the main menu, select Installation and Update Aids. 3. Select Change Configuration. 4. Select Controller Configuration.

Spectrum24 CB 2000 for IBM 4690 Terminals User Guide

18