Page 23
Chapter 2
2.1
Configuring the CB2000
Configuration Requirements CB2000 configuration requires a direct or LAN connection to the bridge and access to the UI (User Interface). To access the UI through a Web browser or SNMP management tool, refer to “Gaining Access to the UI” on page 20.
Spectrum24 CB2000 Client Bridge Product Reference Guide
17
Page 24
Configuring the CB2000
The type of network and level of security used with the CB2000 dictates the steps necessary to configure the device. •
Open system, DHCP server, no special security requirements. Use the CB2000 as it ships from the factory. After connecting the device, the CB2000 establishes a wireless connection with an AP, automatically receives IP and subnet addresses via DHCP and is ready for use. Once operational, use the Spectrum24 CB2000 Management Tool to obtain specific information, such as IP and MAC addresses, which are necessary for relocating the device within the network. The CB2000 factory default configuration is:
18
Property
Default Setting
Device Name
Symbol_CB2000
Device Location
None
Help File Location
Embedded in device
IP Address
Default is 10.1.1.3
Subnet Mask
255.255.0.0
Gateway IP Address
Obtained automatically
Channel Selection
Automatically select the best channel; uses access point setting.
Channel
Uses access point channel.
Wireless LAN Service Area
Attach to any WLAN Service Area automatically
Network Mode
Access Point (infrastructure)
Spectrum24 CB2000 Client Bridge Product Reference Guide
Page 25
Configuring the CB2000
•
Access Point Privacy Mode
Off
Antenna Selection
Diversity
Network Traffic Accelerator
Off (Wi-Fi interoperable)
Data Preamble
N/A (Not applicable)
Security Setting
No Security (Open System)
Administration Password
None
TFTP Server IP Address
None (Uses TFTP port 69)
Closed network with security requirements. For first-time installations, connect the CB2000 directly to a workstation. For device relocation, use the CB2000 Device Manager to locate and configure the CB2000 prior to moving the unit.
Spectrum24 CB2000 Client Bridge Product Reference Guide
19
Page 26
Configuring the CB2000
2.2
Gaining Access to the UI The two primary methods for establishing access to the UI include: •
Using the management tool to locate the device and launch the Configuration Management System
•
Accessing the device directly through a Web browser.
The type of method used depends on whether the workstation used to access the CB2000 has the Device Manager installed and the type of connection used. Select the access that best fits the network environment.
2.2.1
Using the CB2000 Device Manager The Spectrum24 CB2000 Device Manager simplifies the process of accessing the CB2000 to view or change system parameters. Using the Device Manager to gain access to the UI requires the tool be installed and the computer accessing the bridge be on the same subnet. If the computer accessing the CB2000 is on a different subnet, the Pre-IP Configuration Wizard activates automatically. If the subnet settings are changed with the Wizard, users or devices connected to the bridge may lose contact with the LAN. To launch the Device Manager and access the UI: 1. Select Start, Programs, Symbol Wireless, and CB2000 Device Manager. If more than one network adapter is installed on the computer, the user could be prompted to choose a network adapter. Choose the appropriate adapter and click OK. The Wireless Network Tree appears in the Spectrum24 CB2000 Device Manager window. The tree lists all WLAN service areas on the network and expands to show the Spectrum24 CB2000 devices associated with each service area. Devices in a different subnet are
20
Spectrum24 CB2000 Client Bridge Product Reference Guide
Page 27
Configuring the CB2000 identified with exclamation points (!). To refresh this display, click Refresh. Refresh the display, for example, after changing a device IP address. 2. In the Wireless Network Tree, select the device to configure. If more than one wireless LAN device appear in the tree, determine the right one by clicking Properties and checking the MAC address (serial number, located on the bottom of the device) to verify that it is correct. 3. Click Configure. If the selected device is on the same subnet as the computer, the Configuration Management System main page appears in the Web browser. (If a password is set on the device, enter it when prompted.) If the selected device is on a different subnet, the Pre-IP Configuration Wizard is activated automatically. For more information, Refer to “PreIP Configuration Wizard” on page 42. 4. The next window prompts for an administrative password to allow the new IP address to be set. When the units are shipped from the factory, there is no administration password. Enter a password and click Next. The Configuration Management System main page appears in the Web browser.
Spectrum24 CB2000 Client Bridge Product Reference Guide
21
Page 28
Configuring the CB2000
5. View or change configuration parameters as necessary. See online help and Configuring System Parameters on page 23 for additional information on setting and changing configuration settings.
2.2.2
Using a Browser Using a Web browser to gain access to the UI requires the workstation to have a TCP/IP stack and a Web browser. The remote station can be on the wired or wireless LAN. The workstation accessing the UI must be on the same subnet as the device. The Web browser (Internet Explorer 4.0 or greater or Netscape) requires JavaScript to gain access to the UI.
22
Spectrum24 CB2000 Client Bridge Product Reference Guide
Page 29
Configuring the CB2000
To access the CB2000 UI using a Web browser from a workstation: 1. From the NCPA properties window set the IP address of the workstation and the subnet mask. The system prompts the user to reboot for the changes to take effect. 2. To verify the connection, ping the CB2000. At the default DOS prompt, type: ping -t xxxx.xxxx.xxxx.xxxx
–
If the ping receives no response, verify the hardware connections, IP address, gateway address and subnet mask are correct. If correct, contact the site System Administrator for network assistance.
3. Start a Web browser such as Internet Explorer 4.0 or greater, or Netscape 3.0 or greater. Type the IP Address for the associated AP to access the AP using a Web browser: http://xxx.xxx.xxx.xxxaccess
Once accessed, the main page of the Configuration Management System displays an overview of the CB2000 settings, including the Device Name, MAC Address, IP Address, Wireless LAN Service Area, Data Rate, and Signal Strength. Use the mouse to navigate the menus requiring modification.
2.3
Configuring System Parameters CB2000 system parameters configuration requires setting the default parameters to enable the device to communicate with an AP on a specified wireless network (Infrastructure Mode) or another CB2000 (Peer-to-Peer Mode). These settings include: System Properties, IP Network, Wireless Network, and Security Settings.
Spectrum24 CB2000 Client Bridge Product Reference Guide
23
Page 30
Configuring the CB2000
Entering, Clearing, and Applying Configuration Settings Some configuration pages have three buttons: Enter, Clear All Changes, and Apply All Changes. Use these buttons in the following manner: •
Enter stores settings temporarily in the device cache memory, but does not apply them permanently in the device nonvolatile memory. Use Enter to save changes while still configuring the bridge. The changes do not appear on the System Summary page until the user clicks Apply All Changes. Use Enter if making changes on multiple configuration pages, but do not want the changes to take effect until after all have been set.
•
Clear All Changes returns the settings in the device cache memory to the values they had when Apply All Changes was last clicked.
•
Apply All Changes stores the settings permanently in the device nonvolatile memory. After clicking Apply All Changes, the new configuration settings take effect and the changes appear on the System Summary page.
If a user does not click Enter or Apply All Changes before moving to a new configuration page, the changes to the current page are lost. If a user does not click Apply All Changes before resetting the device, the changes are lost. If a user does not click Apply All Changes before closing the browser, the changes remain in the device cache memory, but do not appear in the System Summary until the user starts a new session and clicks Apply All Changes.
24
Spectrum24 CB2000 Client Bridge Product Reference Guide
Page 31
Configuring the CB2000
2.3.1
System Properties Under System Configuration, click System Properties. The System Properties page displays the properties of the selected device. Change properties by entering values in the fields and clicking the radio buttons. When finished, click Enter or Apply All Changes.
2.3.2
•
Device Name. Appears in the System Summary window. Change the default name if desired. The default value is Symbol_CB2000.
•
Device Location. Optionally, enter a location to identify where the device is installed. (For example, Building 4, Cubicle 7.)
IP Network Under System Configuration, click IP Network. The IP Network Properties page appears, where changes to the configuration can be made. Changes made to the IP network settings will disrupt the configuration session when the new settings are applied. To continue a configuration session after applying new IP settings, close the browser and start a new configuration session.
When IP Settings Change 1. Close the browser. 2. Return to the Spectrum24 CB2000 Device Manager and click Refresh. Select the device and click Configure to start a new configuration session. If accessing the UI through a browser, change the workstation IP settings to match the new CB2000 settings and reconnect. Refer to “Using a Browser” on page 22.
Spectrum24 CB2000 Client Bridge Product Reference Guide
25