Network Configuration Communication directly with the CB 1000 allows the following: • use of the serial port applications
• performing a network ping of the CB 1000
• remotely configure the CB 1000 via the telnet protocol.
Bridging does not communicate with the CB 1000 and does not require setting up the basic network parameters.
After completing the Configuration of Radio Settings in 6.1 Configuration of the Radio Settings on page 37, proceed with the following steps to configure the network settings. 1. Click on the Network Tab. The IP Address, Netmask and Gateway fields are displayed.
Spectrum24 CB 1000 User Guide
43
Page 52
Network Configuration
2. Enter an IP address assigned to the CB 1000. The IP address is the network address that other computers use to communicate with the CB 1000. 3. Enter the Netmask. This is a value that defines the range of IP addresses available within the local network. 4. If the network uses a gateway (router or firewall), enter the IP address of the gateway. For serial applications the CB 1000 requires a gateway IP address to access computers or other CB 1000s beyond the Local Area Network (LAN) router or firewall. Enter none if no gateway is present or a gateway is not needed. A gateway is not necessary for Ethernet bridging.
7.1
General Serial Configuration Match the settings of the device connected to the CB 1000 via the RS-232 port. Configure the UART Settings and Flow Control Settings.
7.1.1
UART Settings Universal Asynchronous Receiver/Transmitter (UART) is the fundamental hardware for serial communication. The speed and method of data transfer of the serial port are controlled here. Configure the UART: 1. Click on the Serial tab at the Configuration window.
44
Spectrum24 CB 1000 User Guide
Page 53
Network Configuration
2. Click on the UART tab.
3. Select the baud rate (or type) that matches the device the CB 1000 is connected to. The baud rate indicates the data transfer rate of the serial port. The baud rate ranges from 300 to 115200 bps. Standard rates are 300, 1200, 2400, 9600, 19200, 38400, 57600, 115200. 4. Select the Data Bits setting that matches the device the CB 1000 is connected to. Data Bits determines the number of bits used to transmit data. The possible values are 7 and 8. 5. Select the Stop Bits setting that matches the device the CB 1000 is connected to. Stop Bits determine the number of bits used to represent an end of a character. The value can be 1 or 2. 6. Select the Parity that matches the device the CB 1000 is connected to. The parity bit is used to check for correct data transmission. Options are: none, even, and odd.
Spectrum24 CB 1000 User Guide
45
Page 54
Network Configuration
7.1.2
Flow Control Flow control adjusts the flow of data from one device to another. This ensures the receiving device can handle all of the incoming data. Flow control becomes an important factor when one of the devices is capable of transmitting data at a rate faster than the other can receive it. There are two basic types of flow control, Hardware and Software.
7.1.3
Hardware Flow Control Hardware flow control uses dedicated signal lines to dictate transmission of data and has two options that allow selecting which pair of lines to use for this type of flow control: •
RTS/CTS - Request To Send/Clear To Send
•
DTR/DSR - Data Terminal Ready/Data Set Ready
The Windows flow control setting, Hardware, uses the RTS/CTS pair of flow control lines.
7.1.4
Software Flow Control Software flow control uses two special characters, Xon and Xoff. Xon and Xoff are embedded in the data. These special characters instruct the computer to start and stop sending data. In the incoming direction, flow control prevents the CB 1000 from sending data when the computer is not ready. Enabling incoming flow control, enables the CB 1000 to interpret Xon/Xoff characters in the data stream as flow control signals. The Xon/Xoff characters are not considered part of the data. The outgoing software flow control option specifies the generation of Xon/ Xoff flow control characters by the CB 1000. The control characters are sent out the serial port and instruct the computer to start or stop sending data. This option prevents the computer from sending data when the CB 1000 is not ready to accept it.
46
Spectrum24 CB 1000 User Guide
Page 55
Network Configuration
Software flow control can have both incoming and outgoing mechanisms running simultaneously, individually, or not at all (this is the default).
7.1.5
Flow Control Configuration 1. Click on the Flow Control tab.
2. Check the flow control settings that match the device the CB 1000 is connected to.
7.1.6
Serial Packets The serial packets parameters control the serial to network packet conversion process. Adjusting the default settings is not necessary for the Serial Packet Parameters. These parameters control the way that data received on the serial port is divided into Ethernet packets. The Ethernet packets are sent to serial application network connection. For specific information about the effects of the serial packet parameters see Chapter 11 Serial Stream To Network Packet Conversion on page 71.