Page 19

Chapter 2

Operating Modes The Client Bridge has two different operational modes, Infrastructure and Peer-to-Peer mode, and three networking ports, Ethernet, Spectrum24 and RS-232.

2.1

Infrastructure mode Infrastructure mode connects the CB 1000 Ethernet port with the Spectrum24 port and requires the use of an Access Point (AP). The Client Bridge connects through its Ethernet port to devices that have standard Ethernet capabilities. The Client Bridge associates with a Spectrum24 AP located nearby. The AP sees this Client Bridge/network device combination as a standard Mobile Unit (MU). The AP forms a bridge between the wired LAN and the wireless clients. In infrastructure mode, the AP is a dedicated device that is wired into the LAN back bone while the Client Bridge units can be physically moved throughout the WLAN. The Client Bridge communicates with any device on the network by routing data through the associated AP. Multiple APs with the same ESSID can be placed within the same area. The 802.11 standard enables the Client Bridge to roam among the MUs and APs. Reassociation occurs as long as the Client Bridge has the same ESSID as the AP it is trying to associate with.

10bT

10bT CB 1000

CB 1000

10bT

10bT CB 1000

SP24CBinfrastracture.cdr

Spectrum24 CB 1000 User Guide

11

Page 20

Operating Modes

2.2

Peer-to-Peer Mode Peer-to-Peer mode allows two or more Client Bridge units to communicate exclusively with one another without the use of an AP. Use this mode to connect serial devices (serial line replacement or wireless serial cable) or as an Ethernet bridge between Ethernet devices. •

In this configuration the Client Bridge communicates using the TCP network protocol.

10bT

10bT CB 1000

CB 1000

10bT

10bT CB 1000

CB 1000 SP24HSB4unitsConfig.cdr

12

Spectrum24 CB 1000 User Guide

Page 21

Operating Modes

2.3 Serial Line Replacement . Serial Cable

Serial Cable Client Bridge

Client Bridge SP24lCBserial.cdr

Two CB 1000s are required to perform wireless serial line replacement. Serial line replacement can operate with the radio in either Infrastructure or Peer-to-Peer mode. When performing Serial Line Replacement, data is exchanged using one of two protocols: •

RMP Pipe

•

TCP Pipe.

Spectrum24 CB 1000 User Guide

13

Page 22

Operating Modes

2.4

LED Status and Error Indicators

LED indicators on the Client Bridge include:

14

Power (green)

Indicates power when active.

Status (amber)

Indicates the software has detected an abnormal condition. See event log for status information.

Associated (green)/ Radio Activity (amber)

A green LED indicates association between the CB 1000 and an AP or a MicroAP operating in the Spectrum24 Network. Amber indicates Spectrum24 Radio traffic detected.

Wired LAN Attached (green)/ In Use (amber)

A green LED indicates a connection between the CB 1000 and the wired Ethernet. Lights amber to indicate activity is detected on the wired Ethernet.

Serial Activity Transmit (green)/ Receive (amber)

A green LED indicates the CB 1000 is receiving data through the serial port and displays amber when the CB 1000 is transmitting data through the serial port.

Spectrum24 CB 1000 User Guide

Page 23

Operating Modes

2.5 International Roaming Operation Enable the international roaming mode to automatically adjust the CB 1000 to the country in which it operates. The CB 1000 requires association with an AP to provide country information. To enable International Roaming mode, select International Roaming in the Radio parameter window. After power up, the CB 1000 listens on several channels for 802.11 traffic. When it recognizes a valid frame, it sends an international probe and waits for an international probe response (IPR). If an IPR is received, the CB 1000 copies the appropriate country parameters to the RAM table and adjusts its hopping sequence table. At this point, the CB 1000 can associate with the AP. The CB 1000 keeps the country parameter information as long as it is associated to the AP sending the IPR. An associated CB 1000 probes the AP for a new country code after 20 minutes.

2.6

Data Encryption Mobile nodes and other hosts can be a target of information theft. This occurs when unauthorized users eavesdrop on a network to glean proprietary information. The absence of a physical connection makes wireless links particularly vulnerable to eavesdropping. Encryption becomes the most efficient method in preventing information theft and improving data security. Encryption requires scrambling and coding of information, typically with mathematical formulas called algorithms, before the information is transmitted over a communications link or network. An algorithm is a set of instructions or formula describing how to scramble and encode the data. A key is the unique code used by the algorithm to encrypt or decrypt the data. Decryption is decoding and unscrambling the received encrypted data.

Spectrum24 CB 1000 User Guide

15

Page 24

Operating Modes

The same device, host computer or front-end processor, usually performs both encryption and decryption. The data direction determines which function, encryption or decryption, the device performs. The device takes plain text, encrypts and scrambles the text typically by mathematically combining the key with the plain text as instructed by the algorithm, then transmits the data over the network. At the receiving end, another device unscrambles and decodes the encrypted text revealing the original message. A user can know the algorithm, but cannot interpret the data without the key. Only the sender and receiver of the transmitted data know the secret key. Symbol uses the Wired Equivalent Privacy (WEP) algorithm, specified in IEEE 802.11 section 8, for encryption and decryption. WEP uses the same secret key for both encrypting and decrypting plain text. Typically, an external key management service distributes the secret key. Symbol recommends that users regularly change keys for added security. IEEE 802.11 defines two types of authentication, Open System and Shared Key. Open System authentication is a null authentication algorithm. Shared Key authentication is an algorithm where both the AP and the MU share an authentication key to perform a checksum, an error-checking operation, on the original message. By default, IEEE 802.11 devices operate in an open system network where any wireless device can associate with an AP without authorization. A wireless device with a valid shared key is allowed to associate with the AP. Authentication management messages, also called packets, are unicast, meaning authentication messages transmit between only one AP and one MU, not broadcast or multicast.

16

Spectrum24 CB 1000 User Guide

Page 25

Operating Modes

2.7

Distributed System Mobile Unit DS MU mode is available only with the Spectrum24 2 Mbps FH radio card. Configure APs for WLAP.

The Client Bridge in Distributed System Mobile Unit (DS MU) mode bridges multiple Ethernet stations. The DS MU performs like a wireless AP while retaining the roaming properties of an MU, but does not support associations with other MUs. An MU in DS MU mode functions as part of the distribution system, as defined by 802.11. To configure the Client Bridge for DS MU support: 1. Start the CB Manager utility. The Unit List window displays. 2. Highlight the client to be configured for dsmu In the Unit List window. 3. Select Configure or double click on the client in the Unit List window. 4. Select the Radio tab at the configuration window for the client. 5. Select Advanced. 6. Select yes under the dsmu field. 7. Select Update and Reset the unit.

Spectrum24 CB 1000 User Guide

17

Page 26

Operating Modes

8. A message log window displays indicating the procedure was successful. Select Close to return to the Unit List window.

Once configured, DS MU mode can only be turned off by repeating the above procedure and selecting no in the dsmu field. The associated AP supports four CBs and each CB supports four Ethernet clients, providing the total throughput demanded does not exceed the radio’s capability.

18

Spectrum24 CB 1000 User Guide