The text of a manual · part 13 of 18
Spectrum24 CB 1000 User Guide: Chapter 13 Main Menu Configuration Screens, pages 89 to 97
Pages 89 to 97 of 134, from Spectrum24 CB 1000 User Guide
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol CB-1000
Page 89
Main Menu Configuration Screens
Chapter 13
Main Menu Configuration Screens The following sections list Main Menu options, their functions, and editing information for specific configuration files associated with the Main Menu. CB 1000 serial number 900034 Version 1.00-F2
Symbol Technologies, Inc. Ethernet HW address 00:d0:d8:0d:bb:c2
MAIN MENU ---------
Resume operation Edit configuration View configuration for capture Reset configuration to default View forwarding database View roaming log View system event log Clear system event log Reset the CB 1000
13.1 Navigating the Configurator Editor Selecting one of the Main Menu options displays bring a specific configuration file into the editor. Once inside the editor, use the arrow keys to move the cursor. If the arrow keys do not work with the terminal emulator, use CTRL-P for up (previous), CTRL-N for down (next), CTRL-B for left (back) and CTRL-F for right (forward). See 13.2 Terminal Emulator Control Characters on page 83 for a complete list.
Spectrum24 CB 1000 User Guide
81
Page 90
Main Menu Configuration Screens
Main Menu Option Resume operation
Edit configuration
Result/Action This option exits Configuration. It returns the CB 1000 to the settings the CB 1000 had before the Configure button was pressed. Displays a list of editable files. •
Return to Main Menu –
•
System –
•
Displays the editor screen with the configuration file for options that are not communication dependent.
RS-232 port (uart0) –
•
Returns to the previous menu selection.
Displays the editor screen with the configuration file for the serial port and per-connection network settings.
10BaseT Ethernet (lan0) –
View configuration for capture
Displays the editor screen with the configuration file for the radio parameters and IP network interface settings Enables capture mode in the terminal software. The display scrolls through all configuration settings and gives the option to disable capture mode at the end of the displayed data. Use this option to keep a record of the settings made for a particular CB 1000 unit or to generate a file for Symbol Technologies Technical Support when requested. Sets all configuration files to their factory default.
Reset configuration to default View forwarding database Lists the MAC addresses of all network nodes detected and the network interface. View roaming log Lists the MAC addresses of the access points the CB 1000 has associated/disassociated.
82
Spectrum24 CB 1000 User Guide
Page 91
Main Menu Configuration Screens
Main Menu Option View system error log
Clear system error log Reset the Unit
Result/Action Displays a list of errors that occurred when the Symbol CB 1000 Status LED is lit. See A.3 Event Log Error Table on page 110 for a list of possible error messages. Removes all messages from the error log described above. Performs a hardware reset. Use this after making configuration changes to allow the changes to take effect.
13.2 Terminal Emulator Control Characters The UI uses the following keystrokes to navigate through the menus and screens depending on the terminal emulation. For terminal emulation programs that do not support using ARROW keys or the ENTER key, use the control-character equivalents: UP ARROW or NEXT
CTRL + N
DOWN ARROW or PREVIOUS
CTRL + P
ENTER or SELECT
CTRL + M
LEFT ARROW or BACK
CTRL + B
RIGHT ARROW or FORWARD
CTRL + F
HOME (beginning of line)
CTRL + A
END (end of line)
CTRL + E
BACKSPACE (delete text in back of cursor)
CTRL + H
DELETE (delete text in front of cursor)
CTRL + D
DELETE (text from the cursor to the end of the line) CTRL +K SAVE FILE
CTRL + W
EXIT WITHOUT SAVING
CTRL + X
REFRESH SCREEN
CTRL + L
Spectrum24 CB 1000 User Guide
83
Page 92
Main Menu Configuration Screens
13.3 Configuration File Format The configuration file format is broken down into sections that define a particular grouping of options. The section title contains a section header; which is a string of text surrounded by square brackets [hardware] . The text before the equal sign is a key and the text after the equal sign is the value baud = 9600 . Change the value of different keys to make configuration changes. For example, in the first two lines of the RS-232 uart0 file: [hardware] baud = 9600 data bits = 8 parity = none stop bits = 1
[telnet]
[hardware] is the name of the section. All entries are either key/value pairs
(such as baud = 9600 ) or comments until the next section title (for example The key/value pairs listed before a section name are invalid.
[telnet]).
Comments are stored in the configuration file by inserting a pound sign (#) before the text to be added. Multi-line comments are enabled by inserting the # at the beginning of each line. For example: [telnet] # wait for keystroke or command prompt connect = command prompt # prompts to use in "wait for keystroke" mode (1 = before, 2 = after) wait data 1 = "Press any key to connect to host... "
13.4 Edit Configuration Files Select Edit configuration from the Main Menu to change the settings that pertain to the operation of the Configuration menus as follows:
84
Spectrum24 CB 1000 User Guide
Page 93
Main Menu Configuration Screens
Reset the CB 1000 From the Main Menu for the new settings to take effect.
CB 1000 serial number 900034 Version 1.00-F2
Symbol Technologies, Inc. Ethernet HW address 00:d0:d8:0d:bb:c2
SELECT A FILE -------------
Return to Main Menu system RS-232 port (uart0) 10BaseT Ethernet (lan0)
Use arrow keys, or Ctrl-N and Ctrl-P to move selector bar. Press Enter to make selection.
13.4.1 system Contains the settings controlling the operation of the Configuration menus. [configure] # password is disabled; uncomment and change the next value to enable #password = testpassword
–
Set the password required for entry to the Configuration screen. Up to 12 alphanumeric characters are accepted. Valid characters are numbers and letters. The password is visible only during editing.
Spectrum24 CB 1000 User Guide
85
Page 94
Main Menu Configuration Screens
[bridge] # Access Point refresh ping in units of seconds ap refresh period = 60 ap refresh period
–
Periodically, a CB 1000 pings an access point. The AP Refresh Period is the time (in seconds) between pings. The default is 60 (do not change this default setting). If this default is changed, the access point ignores the CB 1000 unit; and the unit is not found on the network. Having a refresh period active does not affect the performance of the CB 1000.
13.4.2 RS-232 port (uart0) RS-232 serial UART configurations are found on all UARTs that allow communication over the serial port. Configure serial port and devices identically. There are 12 sections available for configuration. Setup only the section applicable to the configuration being used.
hardware [hardware] baud = 9600 data bits = 8 parity = none stop bits = 1
•
The hardware section configures the data transfer rate, number of bits per data transfer, error checking and the number of bits used to signal end of data transfer. Match the serial port and device setup to communicate.
• baud –
86
Selects the data transfer rate of the RS-232 serial port. The baud rate can be between 112.5 and 115,200 bps.The default data transfer rate is 9600. The CB 1000 UART is capable of operating at non-standard speeds.
Spectrum24 CB 1000 User Guide
Page 95
Main Menu Configuration Screens
• data bits –
•
Parity –
•
In a UART character frame, this selects the number of bits that are used to transmit data. Available values are 7 and 8 (default). Sets the parity used in the UART character frame to check for correct data transmission. Options are none (default), odd, and even.
stop bits –
Select the number of bits used to represent an end of character bit in the UART frame. The value can be 1 (default) or 2.
software [software] line length = 1408 # input timeout is specified in msec, and rounded to nearest 10msec input timeout = 10 #delimiters = 0xa # passthrough, passthrough2, telnet, or lpd protocol = passthrough
The software controls the transmission and reception of bytes over the serial port. Correct set-up values enable data transmission between the radio and the serial port. The radio data is packet based and the UART data is stream based. Stream based data is transmitted and received one byte at a time, without any mechanism to separate chunks of data. The devices generating and using the data produced by the stream based packet (serial data) determine how the data is delimited (beginning and end of data). The devices determine the meaning of the packet. Packet based data (radio data) is grouped into chunks of information, destination data is then added to the packet. Computer network traffic is packet based similar to the CB 1000 (radio) that transmits packet based data. The radio in the CB 1000 is a wireless network interface card (NIC) able to communicate with hard wired or wireless computer networks when properly setup. When data is received over the radio (packet based data), the destination information is removed and only the data inside the packet is sent out the serial port (stream based packet).
Spectrum24 CB 1000 User Guide
87
Page 96
Main Menu Configuration Screens
Data received over the serial port is not transmitted as soon as it is received, it is converted into packet based data before the radio can send the data. The CB 1000 uses a set of rules that tell it when to start transmitting data. The destination information is removed and the data extracted from the data packet before radio data transmission. The values in the [software] section define the conversion rules and specify when data can be transmitted over the radio. The data does not get modified by the rules. • line length –
• input timeout –
•
The Input timeout specifies how long the CB 1000 waits after data has been received on the UART and before giving up on waiting for more data. Once a character has been received the timer starts with the input timeout value. If the timer expires, the data is considered to be complete and is transmitted. Conversely, if another character is received before the input timeout is reached, the timer is restarted. The input timeout range for this value is from 10 (default) to 65536 milliseconds, it always rounds up to the nearest tenth millisecond. For instance, setting the timeout to 55 results in the CB 1000 waiting for 60 milliseconds before transmitting the data.
delimiters –
88
Data is transmitted over the radio once the specified number of characters have been received by the UART. The value can range from 1 to 1408 (default), using values too small results in data loss.
Delimiters are special characters that specify the end of the data transmission. Once any of the characters listed in this option are received, the data is transmitted. In serial communications, there is frequently a character reserved to mean "end of transmission". In human-interface applications, this character is the "newline" or Enter key. For computer to computer communication, this value may be different. If one exists, adding it to this list improves communication efficiency. Up to four delimiters can be listed here. They are specified as a space separated list of ASCII values. The values can be written as decimal or hexadecimal numbers.
Spectrum24 CB 1000 User Guide
Page 97
Main Menu Configuration Screens
• protocol
The data format of the communication between the UART and radio network. Protocol values are passthrough, passthrough2, telnet, and LPD. –
Passthrough (default) forwards any data received over the UART or radio interface to the other interface with the data unchanged.
–
Passthrough2 is similar to passthrough, but opens a socket in each direction. If a CB 1000 loses power, it can re-establish communications much faster when power returns.
–
Telnet displays a prompt similar to telnet applications found on UNIX systems. Telnet also interprets the data received over the radio, removing special character sequences known as DO and DONT requests.
–
LPD is a UNIX print serving protocol. LPD receives data in a particular format over the radio, and converts it into the data stream that is sent to the printer. Data sent from the printer is ignored.
When configuring LPD, set the printing parameters so the file is sent using the CB 1000 as the remote host. Any remote printer name can be used so long as it fits within the guidelines for naming a printer.
Spectrum24 CB 1000 User Guide
89